• Title/Summary/Keyword: 선적

Search Result 415, Processing Time 0.026 seconds

A Study on the Experimental Measurements and Its Recovery for the Rate of Boil-Off Gas from the Storage Tank of the CO2 Transport Ship (CO2 수송선 저장탱크의 BOG 측정 실험 및 회수에 관한 연구)

  • Park, Jin-Woo;Kim, Dong-Sun;Ko, Min-Su;Cho, Jung-Ho
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • $CO_2$ is generated by the combustion reaction, when getting the energy from fossil fuel. If the carbon dioxide emissions increases more, the global warming problem will become more serious. CCS (carbon capture storage) needs to be developed for the prevention of this. When liquefied $CO_2$ is transported, BOG (boil-off gas) is generated because of several problems. In the study, by injecting liquefied $CO_2$ in two tanks which contains $40m^3$each, the amount of BOG and its composition were measured during 30 days when generating pressure changes and external heat, loading, unloading. In result, 16,040 kg of BOG was generated and the composition has been found out to be 99.95% $CO_2$ and 0.05 % $N_2$. Also, we conducted simulation process for reliquefaction of generated BOG with vapor compression cycle using the PRO/II with PROVISION version 9.2. As a result, the refrigeration cycle of the total circulation flow rate was 42.07 kg/h and the condenser utility consumption was 48.85 kg/h.

A Study on the Evaluation of Container Terminal Logistics Systems in SCM's Perspective (SCM 관점의 컨테이너터미널 물류시스템 평가)

  • Kim, Sungu;Choi, Yongseok;Yeun, Dongha
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.4
    • /
    • pp.47-67
    • /
    • 2014
  • This study examined elements which could evaluate a container terminal logistics system from the viewpoint of supply chain management. This study derived the elements of a container terminal logistics system such as flexibility, reliability, responsiveness, and information sharing and 16 evaluation sub-items in the aspect of a supply chain. In the result of analysis, the weight between SCM elements of a container terminal logistics system was the highest in reliability(0.282), followed by flexibility(0.273), responsiveness(0.224), and information sharing(0.221). The conversion weight was calculated by combining the weight of elements of a container terminal logistics system and the weight of evaluation sub-items. The highest weight which was considered as the most important factor to evaluate a container terminal logistics system was work planning(berth, yard) of flexibility(0.081), followed by accurate fulfillment of container work schedule(ship, yard) and the optimum distribution and arrangement of equipment(QC, TC, YT)(0.079), stable works without damage of containers and ships(0.071), and preventive maintenance of equipment and operators' skill(0.070).

A Secure AIS Protocol Suggestion with Analyses of the Standard AIS Protocol (표준 AIS 프로토콜 분석을 통한 보안 AIS 프로토콜 제안)

  • Lee, Jung-Su;Heo, Ouk;Kim, Jae-Hwan;Chung, Sung-Wook
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.49-57
    • /
    • 2016
  • Recently, marine accidents such as the sinking accident Mongol freighter ship and the sinking accident of Sewol ferry in Jindo continuously happen. In order to decrease the number of these marine accidents, Korean ships are obliged to follow the AIS(Automatic Identification System) system. The AIS protocol includes all information for sailing ships. However, the standard AIS protocol does not provide any security function, In addition, it is possible to hijack the standard AIS protocol in case of using a satellite communication device called FUNcuve Dongle Pro+. Therefore, this paper analyzes weak points of the security in the standard AIS protocol. Furthermore, this paper ensures reliability by marking the MAC Address of sender and receiver for secure communication and suggests the protocol that can securely send data, using the VPN Tunnelling method. Therefore, the suggested AIS protocol provides the secure communication to the AIS protocol and protect the messages in the AIS protocol, which can serve safe voyages by decreasing the marine accidents.

Conservative and Arthroscopic Treatment of Calcific Tendinitis (석회화 건염의 보존적 및 수술적 치료 결과)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Lee, Ho-Hyoung
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.167-174
    • /
    • 2007
  • Purpose: We evaluated calcium resolution and clinical improvement of calcific tendinitis after conservative and arthroscopic treatment. Materials and Methods: We reviewed 126 patients of calcific tendinitis treated from January, 2002 to April, 2005. Average age was 53 and female dominant in 77% of the cases. Calcium deposits were involved in supraspinatus tendon in 84% of the cases. We compared clinical changes for 64 cases treated with injection, and 12 cases treated by arthroscopic decompression with 6 month follow-up. Results: 77%(49/64) of the cases with steroid injection showed symptom improvement. Even though complete resolution of calcific deposit occurred in 36%(23/64), incomplete resolution in 17%(11/64) and no change in 47%(30/64), Pain was relieved in 87%(20/23), 82%(9/11) and 67%(20/30), respectively. With arthroscopic treatment, calcium deposit completely resolved in 83%(10/12), and all cases showed pain free motion after 6 months. Conclusion: Conservative treatment with steroid injection was effective for acute pain in resorptive phase. In cases of arthroscopic treatment, there was no need for complete removal of calcium deposit during the procedure, but clinical symptoms improved with resolution of the deposit.

Determination of Design Basis for a Storage System for Spent Fuel in Korea (국내 사용후핵연료 저장시스템의 설계기준 설정 인자 고찰)

  • Yoon, Jeong-Hyoun;Lee, Eun-Yong;Woo, Sang-In;Kim, Tae-Man
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • Safe operation and maintenance of engineered dry storage systems for spent fuel from nuclear power plants basically depends on adequately adopted design requirements. The most important design target of the system are those which provide the necessary assurances that spent fuel can be received, handled, stored and retrieved without undue risk to health and safety of workers and the public. To achieve these objectives, the design of the system incorporates features to remove spent fuel residual heat, to provide for radiation protection, and to maintain containment over the lifespan of the system as specified in the design specifications. The features also provide for all possible anticipated operational occurrences and design basis events in accordance with the design basis as guided by the designated regulations. The general performance requirements of a projected storage system are introduced in this paper. The storage system is designed to store fuel assemblies in associated with designated regulatory requirements. Small increases/decreases in maximum burnup can be adjusted with cooling time. These variations are compensated for by a corresponding small site-specific increase/decrease in the design basis-cooling period, as long as the maximum heat load and radioactivity of loaded fuel assemblies are met. Generic design basis events considered for the storage system are summarized. Shielding and radiological requirements along with mechanical and structural are derived in this study.

State-of-Arts of Primary Concrete Degradation Behaviors due to High Temperature and Radiation in Spent Fuel Dry Storage (사용후핵연료 건식저장 콘크리트의 고열과 방사선으로 인한 주요 열화거동 분석)

  • Kim, Jin-Seop;Kook, Donghak;Choi, Jong-Won;Kim, Geon-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.243-260
    • /
    • 2018
  • A literature review on the effects of high temperature and radiation on radiation shielding concrete in Spent Fuel Dry Storage is presented in this study with a focus on concrete degradation. The general threshold is $95^{\circ}C$ for preventing long-term degradation from high temperature, and it is suggested that the temperature gradient should be less than $60^{\circ}C$ to avoid crack generation in concrete structures. The amount of damage depends on the characteristics of the concrete mixture, and increases with the temperature and exposure time. The tensile strength of concrete is more susceptible than the compressive strength to degradation due to high temperature. Nuclear heating from radiation can be neglected under an incident energy flux density of $10^{10}MeV{\cdot}cm^{-2}{\cdot}s^{-1}$. Neutron radiation of >$10^{19}n{\cdot}cm^{-2}$ or an integrated dose of gamma radiation exceeding $10^{10}$ rads can cause a reduction in the compressive and tensile strengths and the elastic moduli. When concrete is highly irradiated, changes in the mechanical properties are primarily caused by variation in water content resulting from high temperature, volume expansion, and crack generation. It is necessary to fully utilize previous research for effective technology development and licensing of a Korean dry storage system. This study can serve as important baseline data for developing domestic technology with regard to concrete casks of an SF (Spent Fuel) dry storage system.

A Study of Evaluation Indices for Selecting Castle Remains Maintenance and Restoration Sections (성곽유적의 정비복원(整備復元) 대상구간 선정을 위한 평가지표 연구)

  • Kim, Hong-Gon;Choi, Key-Soo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Most of all Castle Remains in Korea were built on an axis of development with a scale of great magnitude. Because of its characteristics, the restoration and conservation plans should be phased in over medium and long term. There is no standards for evaluating the value of Castle Remains to set up the restoration and conservation sections. Some plans were set up through the value evaluation of its Castle Remains but those plans didn't have Evaluation System and different weight depending on different environment between Sanseong(mountain fortress) and Eupsung(fortress built in villages). To solve the limitation of Evaluation System of Castle Remains, this study try to approach in the Evaluation System methodology for selecting restoration sections. The results of its study follow below. First, this study drew the Evaluation Indices for selecting restoration sections of Castle Remains. There are three kinds of Elements(upper Index) and nine kinds of Evaluations(low Index). Second, Calculation of weight index by index on the questionnaire survey from expers through the relative importance analysis of AHP. Third, This study suggests the specific Evaluation System according to types; Sanseong(mountain fortress) and Eupsung(fortress built in villages);. Therefore, this study suggests standards to select the priority list for the restoration and conservation plan process and it can be used one of important standards in future plans.

Development of a Solar Concentrator having the Reflecting Surface with the 2m Class Diameter (직경 2m급 반사면을 가지는 태양열 집광 장치 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 2008
  • Purpose: To develop a solar concentrator having the reflecting surface with the 2m class diameter. Methods: In order to make the reflecting surface for the solar concentrator, the shape of the reflecting surface sector is required. So, first, we induced the formula that can produce this shape. After that, using Delphi 6.0 language, we developed a program which uses this formula and produces the shape and the numerical data of the reflecting surface sector with the input variables such as the external diameter of the reflecting mirror, the reflecting mirror's radius of curvature at the paraxial range, the number of reflecting mirror sector, the size of the center hole of the reflecting mirror, and the interval of the output data. Results: This program, which was developed to produce the shape and the numerical data of the reflecting surface sector, enables us to see the shape of sector on the monitor and to save the numerical data files for the shape of sector. As a result, the user of this program can easily access the numerical data of the reflecting surface sector. Conclusions: Developing the program which produce the reflecting surface sector used to make the reflecting surface of the solar concentrator, we could succeed in making the prototype products by applying it to the development of the real solar concentrator with the diameter of the 2m class.

  • PDF

The Factors Related to Intractability in Patients with Partial Epilepsy (부분성 간질환자에서 난치성에 관여하는 인자)

  • Lee, Yeung-Ki;Byun, Yeung-Ju;Park, Mee-Yeong;Hah, Jung-Sang;Lee, Se-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.306-318
    • /
    • 1995
  • To evaluate the intractability of partial epileptic patients by variables, the author studied 113 patients (uncontrolled: 45, controlled: 68) who were admitted to the Department of Neurology, College of Medicine, Yeungnam University from January, 1991 to August, 1993. The results were as follows. The items related to complex partial seizures, multiple seizure types and a histories of status epilepticus or clusters of seizures were significantly associated with drug-refractoriness (p<0.01). A high frequency of seizures before evaluation was associated with a poor outcome(p<0.01). The presences of known etiology of seizures, neurologic abnormalities and psychiatric disturbance were associated with limited treatment responses(p<0.01, p<0.05, p<0.01). An abnormal EEG findings such as background slowing, focal slowing, epileptiform discharges or secondarily bilateral synchrony were statistically significant (p<0.01). Age at onset, sex, distribution of epileptic foci, duration of seizure before evaluation, family history and abnormal neuroradiologic findings were not statistically significant. By these results, it was suggested that having at least four factors of the above variables were associated with limited treatment response.

  • PDF

Comparison between Chronic Ulnar and Radial Collateral Ligament Repairs in the Metacarpophalangeal Joint of the Thumb (무지 중수지 관절의 만성 파열된 척측, 요측 측부 인대 봉합술 후 결과 비교)

  • Lee, Sanglim;Ha, Jiyun;Kim, Ji Yeong;Jeon, Suk Ha
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.254-261
    • /
    • 2018
  • Purpose: Favorable results have been reported after the direct repair of chronic ulnar collateral ligament ruptures of the thumb metacarpophalangeal (MP) joint, but the results for radial ligament seem rather controversial. The purpose of this study is to compare the results of ligament reattachment between chronic rupture of the ulnar and the radial collateral ligament (RCL) of the joint. Methods: We reviewed retrospectively the radiologic and clinical results of ligament reattachment with suture anchors for chronic (more than 6 weeks) rupture of the collateral ligament of the thumb MP joint with averaged 22-month follow-up. The data between 6 radial and 8 ulnar ligament repairs were compared statistically. Results: The average of postoperative ulnar deviation angle was $13.3^{\circ}$ in radial ligament and $2.0^{\circ}$ in ulnar ligament (p=0.020) in the last follow-up plain X-ray. Postoperative ligament instability was positive in 4 out of the 6 radial repairs and no case with instability was observed in ulnar ligament. In postoperative follow-up, sustained joint subluxation was observed only in 2 out of the 6 radial repairs. Conclusion: The delayed repair of the RCL of the thumb MP joint resulted in less favorable outcomes and ligament instability was observed postoperatively in more than half of the cases.