• Title/Summary/Keyword: 선원

Search Result 1,482, Processing Time 0.022 seconds

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

The Legal Response and Future Tasks regarding Oil-Spill Damage to Korea - Focusing on the Hebei Spirit oil-spill (한국의 해양유류오염피해에 대한 법적 대응과 과제 - HEBEI SPIRIT호 유류유출사고를 중심으로 -)

  • Han, Sang-Woon
    • Journal of Environmental Policy
    • /
    • v.7 no.3
    • /
    • pp.89-120
    • /
    • 2008
  • With petroleum being a major source of energy in Korea, the quantity of petroleum transported via ocean routes is on its way up due to increased consumption. Due to the increase, more than 300 cases of pollution caused by petroleum occur annually. Moreover, the number of oil-spill accidents is also on the rise. Causes of such accidents, not including the disposal of waste oil on purpose, turn out to be human error during navigation or defects in the vessels, showing that most accidents are caused by humans. Therefore, to prevent future oil spills, it is imperative that navigation efficiency be enhanced by improving the quality of navigators and replacing old vessels with newer ones. Nevertheless, such improvements cannot occur overnight, so long- and mid-term efforts should be made to achieve it institutionally. As large-scale oil-spill accidents can happen at anytime along the coastal waters of Korea, it is necessary to set-up institutional devices which go beyond the compensation limit of 92FC. The current special law regarding this issue has its limits in that it prescribes compensation be supplemented solely by national taxes. Therefore, the setting-up of a new 'national fund' is recommended for consideration rather than to subscribe to the '2003 Convention for the Supplementary Fund'. It is strongly suggested that a National fund be created from fees collected from oil companies based on the risks involved in oil transportation and according to the profiteers pay principle. In addition, a public fund should be created to handle general environmental damage, such as the large-scale destruction of the ecosystem, which is distinct from the economic damage that harms the local people. The posterior responses to the large-scale oil spill have always been unsatisfactory because of the symbolic nature of the disasters included in such accidents. Oil-spills can be prevented in advance, because they are caused by human beings. But once they occur, they inflict long-term damage to both human life and the natural ecosystem. Therefore, the best response to future oil-spills is to work to prevent them.

  • PDF

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI (두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교)

  • Choi, Seung-Jin;Byun, Sung-Su;Park, Sun-Won;Kim, Young-Mo;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.309-315
    • /
    • 2006
  • Purpose: Accurate evaluation of cervical lymph node (LN) metastasis of head and neck squamous cell canter (SCC) is important to treatment planning. We evaluated the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of cervical LN metastasis of head and neck SCC and performed a retrospective comparison with CT/MRI findings. Materials & Methods: Seventeen patients with pathologically proven head and neck SCC underwent F-18 FDG PET/CT and CT/MRI within 4 week before surgery. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. F-18 FDG PET/CT images were analyzed visually for assessment of regional tracer uptake in LN. We analyzed the differences in sensitivity and specificity between F-18 FDG PET/CT and CT/MRI using the Chi-square test. Results: Among the 17 patients, a total of 123 LN levels were dissected, 29 of which showed metastatic involvement. The sensitivity and specificity of F-18 FDG PET/CT for detecting cervical LN metastasis on a level-by-level basis were 69% (20/29) and 99% (93/94). The sensitivity and specificity of CT/MRI were 62% (18/29) and 96% (90/94). There was no significant difference in diagnostic accuracy between F-18 FDG PET/CT and CT/MRI. Interestingly, F-18 FDG PET/CT detected double primary tumor (hepatocellular carcinoma) and rib metastasis, respectively. Conclusion: There was not statistically significant difference of diagnostic accuracy between F-18 FDG PET/CT and CT/MRI for the detection of cervical LN metastasis of head and neck SCC. The low sensitivity of F-18 FDG PET/CT was due to limited resolution for small metastatic deposits.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Pattern of Pusan Station Shopping District( I ) (부산역(釜山驛) 상점가(商店街)의 패턴( I ))

  • Kim, Won-Kyung
    • Journal of the Korean association of regional geographers
    • /
    • v.5 no.1
    • /
    • pp.25-75
    • /
    • 1999
  • This study concern with the pattern of Pusan Station Shopping District within Pusan City, Korea, one of the third ranked centers within Pusan-the first ranked is CBD, the second is subCBD, the third are Spa Shopping district, Tongnae shopping district, Jobang-Ap shopping district and Yangjeong shopping district. This paper serves as a part of series studies which attempt to clarify the internal structure of Pusan as a whole. Part(I) of this study deals with the pattern of functions including information & culture, business, recreation and retailing. The results are as follows. 1. Pusan Station is one of higher ranked class of central places within Pusan City. But the ratio of dwelling houses is the highest in Pusan Station among the 9 higher ranked central places within Pusan. It means that the residential areas still remain along the maze type of narrower streets inner part of the blocks, especially western belt of this shopping district. 2. Business functions are one of the important criteria which classified the central places within the city and Pusan Station is the first ranked shopping districts in terms of these criteria among the 9 higher ranked central places including CBD within Pusan City. It suggests that Pusan Station is the miniature of the CBD, SubCBD is not the miniature of CBD in the view point of business function. It also means that Pusan Station Shopping District has been developed as a special shopping district or as a special central place. It has not been evolved as a center of the hierarchy of central places within the city by the natural or organic growth. 3. Pusan Station as 'the third space or drinking place' and it's characteristics as a amusement center presents at so called the 'Texas Town'-free tax area- whose customers are mainly U. S. soldiers and foreign sailors. But from the 1990s, this 'Town' changed to 'Russian Town', You can easy to meet many Russians and Russian lettered signboards-not English- along the street. 4. Convenient stores distribute mainly at back streets or along the narrower streets. It means that this kinds of stores have a residential oriented character. And a certain convenient stores locate with almost same distances. It suggests that it's hinterland is limited in nearer neighborhoods.

  • PDF

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

PET/CT SUV Ratios in an Anthropomorphic Torso Phantom (의인화몸통팬텀에서 PET/CT SUV 비율)

  • Yeon, Joon-Ho;Hong, Gun-Chul;Kang, Byung-Hyun;Sin, Ye-Ji;Oh, Uk-Jin;Yoon, Hye-Ran;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • The standard uptake values (SUVs) strongly depend on positron emission tomographs (PETs) and image reconstruction methods. Various image reconstruction algorithms in GE Discovery MIDR (DMIDR) and Discovery Ste (DSte) installed at Department of Nuclear Medicine, Seoul Samsung Medical Center were applied to measure the SUVs in an anthropomorphic torso phantom. The measured SUVs in the heart, liver, and background were compared to the actual SUVs. Applied image reconstruction algorithms were VPFX-S (TOF+PSF), QCFX-S-350 (Q.Clear+TOF+PSF), QCFX-S-50, VPHD-S (OSEM+PSF) for DMIDR, and VUE Point (OSEM) and FORE-FBP for DSte. To reduce the radiation exposure to radiation technologists, only the small amount of radiation source 18F-FDG was mixed with the distilled water: 2.28 MBq in the 52.5 ml heart, 20.3 MBq in the 1,290 ml liver and 45.7 MBq for the 9,590 ml in the background region. SUV values in the heart with the algorithms of VPFX-S, QCFX-S-350, QCFX-S-50, VPHD-S, VUE Point, and FOR-FBP were 27.1, 28.0, 27.1, 26.5, 8.0, and 7.4 with the expected SUV of 5.9, and in the background 4.2, 4.1, 4.2, 4.1, 1.1, and 1.2 with the expected SUV of 0.8, respectively. Although the SUVs in each region were different for the six reconstruction algorithms in two PET/CTs, the SUV ratios between heart and background were found to be relatively consistent; 6.5, 6.8, 6.5, 6.5, 7.3, and 6.2 for the six reconstruction algorithms with the expected ratio of 7.8, respectively. Mean SNRs (Signal to Noise Ratios) in the heart were 8.3, 12.8, 8.3, 8.4, 17.2, and 16.6, respectively. In conclusion, the performance of PETs may be checked by using with the SUV ratios between two regions and a relatively small amount of radioactivity.