• Title/Summary/Keyword: 선암

Search Result 528, Processing Time 0.028 seconds

Usefulness of $^{18}F$-Fluoride PET/CT in Bone Metastasis of Prostate Cancer (전립선암 환자의 뼈 전이에 대한 $^{18}F$-Fluoride PET/CT의 유용성)

  • Park, Min-Soo;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.24-30
    • /
    • 2009
  • Purpose: Today, Prostate cancer has been gradually increasing, according to the change of internal incidence rate of cancer. Generally, prostate cancer has lead to dead over 90%, in case of metastasis of lymph node and bone. So, innovative development of new radiopharmaceutical and imaging modality is progressed for detection of that metastasis, in nuclear medicine, now. Therefore, this study shows the usefulness of $^{18}F$-Fluoride PET/CT improved diagnosability on bone metastasis of prostate cancer. Materials and Methods: In this study, 33 male patients with prostate cancer were examined (The mean age: $67.8{\pm}10.2$ years old). Every patient was done each whole body bone scan (WBBS) and $^{18}F$-Fluoride positron emission tomography/computed tomography ($^{18}F$-Fluoride PET/CT). And then, using Receiver Operating Characteristic Curve (ROC curve), each sensitivity and specificity of two modalities was measured and compared with. Results: In 22 patients (66.6%) of all, bone metastasis was detected. And, in WBBS, sensitivity was 63.6%, specificity, 81.8%; in $^{18}F$-Fluoride PET/CT, sensitivity was 100% and specificity was 90.9%. As a result of ROC curve, AUROC (The Area under an ROC) of WBBS was 0.778, and that of $^{18}F$-Fluoride PET/CT, 0.942. Conclusions: $^{18}F$-Fluoride PET/CT was higher both sensitivity and specificity than WBBS, and it was valuable to detect bone metastasis of prostate cancer more definitely, with 3D imaging realization. Also, in $^{18}F$-Fluoride PET/CT, physiological images were acquired in more short time than WBBS, so, it was possible to reduce patient's waiting time and complaint. Therefore, it is considered that $^{18}F$-Fluoride PET/CT is able to improve diagnosability by offering more accurate images, as cuts in a share of high cost.

  • PDF

A STUDY ON THE FOOD OF THE GOBY, SYNECHOGOBIUS HASTA (풀망둑 Synechogobius hasta (TEMMINCK et SCHLEGEL)의 먹이 조사)

  • PAIK Eui-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.47-62
    • /
    • 1969
  • A goby, Synechogobius hasta (Temminck et Schlegel) was studied to investigate the food consumed and the biological change of the food organisms, and the fish were sampled from the closed tributary and the lower Part of the Naktong River, near Pusan, during the period from November of 1967 to December of 1968. The fish were sampled from four stations (Fig. 1), the total number of fish being 1,295 and they were grouped and analysed monthly. The content of the alimentary canal was analysed in three categories according to modified Nilsson's method (Dahl 1962) with a slight alteration: 1) The number of each item of stomach contents was counted and the percentage of each item in proportion to the total number of food organisms is indicated by the letter 'N' representing numerical percentage in Table 2. 2) The percentage of fish which contained any items of food organisms in proportion to the total number of fish caught in a given season is indicated by the letter 'O' representing frequency of occurrence. 3) Dominant groups of food items were selected and the percentage of the number of each dominant item in proportion to the number of the food organisms belonging to the dominant groups is indicated by the letter 'D' representing dominance. All food organisms were classified in 50 food item categories and then they were grouped in 13 main groups (Fig. 2-1), and they were further divided into 1) obligatory bottom animals, 2) organic drifts and 3) actively swimming forms; according to the conditions of the animal communities within the habitat. Since the majority of its food was composed of the obligatory bottom animals ($94.6\%$), the fish appeard to be a typical bottom feeder. And the dominant food organisms of the fish is generally determined by the local composition of the benthic fauna within the fish habitat. And their seasonal rhythm occurs among the food organisms in the stomach by the biological interaction. Locality variation in the population of the same food organism occurs due to the difference of food organisms in the habitat of the fish at Seonam and Garak, and at Seongsan and Hadan the condition of the niche for the fish in the both regions seems to be the same since the composition and the seasonal variation of the organisms were the same. The results may be summarized as follows: 1) The goby mainly feed on the animals of bottom fauna, and the food organisms are deter-mined by the food compositions within the habitat. 2) Seasonal variation of the stomach content shows the seasonal rhythm due to the biological variation of the population and their interaction. 3) The goby shows no preference on specific food, and the food is composed of a variety of animals. 4) Major food items of the goby are Polychaeta, Palaemon modestus, Isopoda, Gammaridea, Insecta (nymphs and larvae), Ilyoplax deschampsi, and Paratye compressa. 5) Logitudinal succession oil the population of the food organisms is apparently recognized within the community of Seongsan, Garak and Seonam. 6) The goby begins to descend toward the estuary and sea around April when the water temperature reaches $20^{\circ}C$, and they begin to return to river waters in September.

  • PDF

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

Clinical Charicteristics of Primary Lung Cancer Patients in a Tertiary Hospital (3차 의료기관에서 진단된 원발성 폐암의 임상적 특성)

  • Ryu, Jeong-Seon;Lee, Hun-Jae;Leem, Jong-Han;Kim, Lucia;Lee, Kyung-Hee;Cho, Jae-Hwa;Yoon, Young-Han;Kwak, Seung-Min;Lee, Hong-Lyeol;Kim, Kwang-Ho;Loh, John-Kyu;Jung, Soo-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.3
    • /
    • pp.321-329
    • /
    • 2006
  • Background : To evaluate the clinical characteristics of lung cancer patients in Korea, where there is a higher number of smokers than in Western countries. Methods : A retrospective study was performed on 1655 lung cancer patients, who were diagnosed at a university hospital between September 1996 and August 2005. Age, gender, cell types and clinical stage were analysed. Of 941 patients, who responded to a questionnaire at the time of diagnosis, the smoking habits, occupational history, family history of lung cancer in the first-degree relatives, coexisting diseases (diabetes mellitus and cardiovascular disease), body weight loss, ECOG performance status and presenting symptoms, were examined prospectively. In addition, coexisting diseases including chronic obstructive pulmonary disease, idiopathic pulmonary fibrosis and active pulmonary tuberculosis were evaluated. Results : Of the 1655 patients, the male to females ratio was 3.6. Squamous cell carcinoma was the most common cancer whereas adenocarcinoma was more common in lifetime nonsmokers or women. 19.9% of the patients were non smokers and 80.1% ever smokers. Since 2000, there was an increase in the incidence of adenocarcinoma with a corresponding decrease in the incidence of squamous cell carcinoma. 6.2% of patients were asymptomatic. A coincident diagnosis of chronic obstructive pulmonary disease, cardiovascular disease, diabetes mellitus, active pulmonary tuberculosis, and idiopathic pulmonary fibrosis was made in: 44.1%, 22.2%, 10.7%, 3.9%, and 1.6% of patients, respectively. A positive family history of lung cancer in the first-degree relatives was identified in 4.4% of patients. An occupational history relevant to lung cancer was identified in 12.2% of patients. Conclusion : There is a high proportion of cigarette smokers in Korean lung cancer patients. The most common cell type was squamous cell carcinoma. However, a more detailed, prospective study of the clinical characteristics will be needed to better characterize lung cancer in Korea.

The Correlation between Bronchoscopic Morphology and Pathologic Type in Bronchogenic Carcinoma (폐암의 기관지 내시경 소견과 세포형의 연관성에 관한 연구)

  • Lee, Hyuk-Pyo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.389-396
    • /
    • 1994
  • Background : The two most important purposes of fiberoptic bronchoscopy in lung cancer patients are obtaining tissue diagnosis and staging. The direct sign of lung cancer on FOB includes visible tumor, with smooth or nodular surface, with or without necrosis and infiltration. Variant cell types of lung cancer have their characteristic biological behaviors respectively. For example, squamous cell carcinoma grows slowly, invades locally and has easy necrosis resulting in cavitation, whereas adenocarcinoma shows early metastasis, small cell carcinoma shows rapid growth and higher early metastasis rate. Based on this, it could be hypothesized that each cell type may have characteristic bronchoscopic finding. Method : To answer this question, we reviewed 106 cases which were diagnosed as primary lung cancer and had bronchoscopically visible specific cancerous lesions. Results : The results were as follows. 1) Squamous cell carcinoma accounted for 66 cases(62.2%), adenocarcinoma 15 cases(14.2%), large cell carcinoma 3 cases(2.8%). 2) The endobronchial tumor lesion was arbitrarily classified into 5 types according to gross characteristics. Type A, multilobulating mass with necrosis, accounted for 24.5%, type B, multilobulating mass without necrosis, 25.5%, type C, round beefy mass, 9.4%, type D, infiltration with mucosal irregularity, 6.6%, and type E, infiltration without mucosal irregularity, 34%. 3) The analysis of correlation between endobronchial tumor pattern and specific cell type revealed that squamous cell carcinoma had relation with the morphologic type B and small cell carcinoma had relation with the morphologic type E, but adenocarcinoma had no preponderance in morphologic type. The gross appearance had influence on the diagnostic yields of biopsies and the diagnostic yields of lobulating mass types(type A, B) were higher than those of other types. Conclusion : From the above observations, it could be concluded that squamous cell carcinoma and small cell carcinoma have relations with specific types of bronchoscopic morphology, but not the case in adenocarcinoma.

  • PDF

Radical Radiotherapy for Carcinoma of the Prostate (전립선암의 근치적 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.40-44
    • /
    • 2001
  • Purpose : To evaluate effect and tolerance of external beam radiotherapy for carcinoma of the prostate and define the optimal radiotherapeutic regimen. Materials and methods : We retrospectively analyzed the records of 60 patients with prostate cancer who were treated with external beam radiotherapy with curative intent in our institution between September, 1987 and March, 2000. Histologic diagnosis was established by transurethral resection or ultrasonography guided biopsy. The major presenting symptoms were a nodule at routine prostatic examination and frequency and urgency of urination, along with dysuria. The median age was 63 years with range of 51 to 87 years. There were 6 patients in Stage A, 20 in Stage 8, 26 in Stage C, and 8 in Stage Dl. All patients were treated with megavoltage equipment producing 10 MV photons. The 4 field pelvic brick technique was used to a dose of 45 Gy or 50.4 Gy at 1.8 Gy per day in 5 to 6 weeks, after which a small boost field was delivered 2.0 Gy per day to a total dose of 66 to 70 Gy. The follow-up period ranged from 1 to 8 years. Results : Actuarial 5-year and 7-year survival rates for Stage A, B, C, and D1 were $100\%\;and\;84\%$, $83\%\;and\;72\%$, $67\%\;and\;54\%$, and $v$, respectively. The corresponding 5-year and 7-year relapse free survival rates were $84\%\;and\;84\%$, $77\%\;and\;67\%$, $48\%\;and\;40\%$, and $33\%\;and\;25\%$, respectively. Relapse free 5-year survival rates for Stage B were $80\%,\;80\%,\;and\;50\%$ for well, moderately, and poorly differentiated tumors, respectively. These were $64\%,\;44\%,\;and\;33\%$ for Stage C, respectively. The local control rates at 5 years were $84\%,\;85\%,\;78\%,\;and\;60\%$ for Stage A, B, C, and D1, respectively. Mild to moderate complications were observed in $22\%$ of patients. Severe complications requiring surgical procedures were documented in only $3\%$ of patients. Conclusion : This study confirms that external beam irradiation is an effective and safe treatment for prostatic cancer, providing long-term local control and good survival with acceptable complications.

  • PDF

A Study on Image Reconstruction for Seed Localization for Permanent Prostate Brachytherapy (전립선암 근접치료 시 방사성선원 위치확인을 위한 영상 재구성에 관한 연구)

  • Hong, Ju-Young;Rah, Jeong-Eun;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.125-133
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to design and fabricate a phantom for prostate cancer brachytherapy to validate a developed program applying a 3-film technique, and to compare it with the conventional 2-film technique for determining the location of an implanted seed. $\underline{Materials\;and\;Methods}$: The images were obtained from overlapped seeds by randomly placing a maximum of 63 seeds in the anterior-posterior (AP) position and at $-30^{\circ} to $30^{\circ} at $15^{\circ} intervals. Images obtained by use of the phantom were applied to the image processing procedure, and were then processed into the development program for seed localization. In this study, cases were set where one seed overlapped, where two seeds overlapped and where none of the three views resolved all seeds. The distance between the centers of each seed to the reference seed was calculated in a prescribed region. This distance determined the location of each seed in a given band. The location of the overlapped seeds was compared with that of the 2-film technique. $\underline{Results}$: With this program, the detection rate was 92.2% (at ${\pm}15^{\circ}), 94.1% (at ${\pm}30^{\circ}) and 70.6% (compared to the use of the 2-film technique). The overlaps were caused by one or more than two seeds that overlapped; the developed program can identify the location of each seed perfectly. However, for the third case the program was not able to resolve the overlap of the seeds. $\underline{Conclusion}$: This program can be used to improve treatment outcome for the brachytherapy of prostate cancer by reducing the number of errors in the process of reconstructing the locations of perfectly overlapped seeds.

Histologic Accuracy of Diagnostic Methods in Lung Cancer (폐암에서 진단수기의 조직학적 분류의 정확성에 관한 연구)

  • Lee, Sang-Min;Koh, Won-Jung;Yoon, Ho-Il;Choi, Seung-Ho;HwangBo, Bin;Park, Gye-Young;Yoo, Chul-Gyu;Lee, Choon-Taek;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.488-497
    • /
    • 1999
  • Background : Identification of the histologic cell type of lung cancer is important because it is related to the treatment modality and prognosis. Currently, many diagnostic methods are used to determine the cell type. We have studied to evaluate the histologic accuracy of each diagnostic methods in lung cancer. Method : 168 cases were analysed retrospectively, who underwent curative thoracotomy for lung cancer in Seoul National University Hospital from January, 1994 to February, 1997. Sputum cytology, percutaneous needle aspiration(PCNA), percutaneous needle biopsy(PCNB), bronchial washing cytology and flexible bronchoscopic biopsy were evaluated respectively. The k coefficient was applied to evaluate the degree of concordance between the histologic diagnosis obtained by each methods and the one derived from thoracotomy. Results : The k value in sputum cytology was 0.86. In the 34 cases with squamous cell carcinoma(SQ), 32 cases were finally diagnosed as having such by thoracotomy. 7 of the 8 cases with adenocarcinoma(AD) turned out to have the same. The k value in PCNA was 0.51. In the 31 cases with SQ, only 14 cases were finally diagnosed as having such. All of the 3 cases with small cell carcinoma(SC) turned out to have the same. The k value in PCNB was 0.77. The diagnosis was correct in 13 of the 16 patients with SQ and in 30 of the 32 cases with AD. The k value in bronchial washing cytology was 1.0. In all of the 29 cases with SQ and all of the 7 cases with AD, the diagnosis was correct. The k value in flexible bronchoscopic biopsy was 0.77. The diagnosis was correct in 51 of the 52 cases with SQ and in 1 of the 2 cases with SC. Conclusion : The concordance rate with the final histologic diagnosis in sputum cytology, PCNB, bronchial washing cytology and flexible bronchoscopic biopsy were excellent ($k{\geq}0.75$), while that in PCNA was fair (k=0.53). Because PCNA showed lower concordance rate than other diagnostic methods, PCNA is recommended to perform with PCNB.

  • PDF

Dynamic Contrast-Enhanced MR Imaging in Detecting Local Tumor Progression after HIFU Ablation of Localized Prostate Cancer (국소적 전립선암의 고강도 집속 초음파 치료 후 국소적 암 재발의 발견과 역동적 조영증강 자기공명영상의 역할)

  • Park, Jung Jae;Kim, Chan Kyo;Lee, Hyun Moo;Park, Byung Kwan;Park, Sung Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • Purpose : To retrospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging (DCE-MRI) in detecting recurrent prostate cancer after HIFU of clinically localized cancer, as compared with T2-weighted imaging (T2WI). Materials and Methods: Twenty-six patients with increased prostate-specific antigen levels after HIFU were included in this study. All MR examinations were performed using T2WI and DCE-MRI, followed by transrectal ultrasound-guided biopsy. MRI and biopsy results were correlated in six prostate sectors. Residual or recurrent cancer after HIFU was defined as local tumor progression if biopsy results showed any cancer foci. Two independent readers interpreted the MR images. Results: Of 156 prostate sectors, 51 (33%) were positive for cancer in 17 patients. For detecting local tumor progression, the sensitivity of DCE-MRI and T2WI was 80% and 57% for reader 1 (P < 0.001) versus 84% and 61% for reader 2 (P < 0.001), respectively. The specificity and overall accuracy between DCE-MRI and T2WI showed no statistical difference in both readers (P > 0.05). Interobserver agreement of DCE-MRI and T2WI was moderate and fair, respectively. Conclusion: For detecting local tumor progression of prostate cancer after HIFU, DCE-MRI was more sensitive than T2WI, with less interobserver variability.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.