• Title/Summary/Keyword: 선박평형수처리장치

Search Result 49, Processing Time 0.026 seconds

Numerical study on fluid characteristics due to disc shape in a novel mechanical ballast water treatment system (신개념 기계식 선박평형수 처리장치의 디스크 형상에 따른 유동특성에 관한 수치해석 연구)

  • Sohn, Sang-Ho;Kim, Young-Chul;Choi, Kung-Kwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • As the recent regulation of Internaional Maritime Organization (IMO) is enforced, the advanced technology of Ballast water treatment system (BWTS) is needed to meet its requirements. Until now, there are two kinds of the BWTS technologies such as physical methods (Membrane and UV) and chemical methods (Chlorin and Ozone). However, these conventional methods have some limitations of auxiliary power, low productivity, residual treatment and etc. In order to overcome these problems, this paper introduces the new kind of BWTS based on mechanical principle and investigates the effect of rotating disc shapes on flow characteristics between rotating and stationary discs by computational fluid dynamics (CFD). Planar and Step types can make the local cavitation generated along radius, and Circular type can increase the intensity of shear stress.

Android Remote Monitoring System of Ballast Water Treatment System (선박 평형수 처리 시스템의 안드로이드 원격 모니터링 시스템)

  • Choi, Hwi-Min;Seo, Ji-No;Lee, Kwang-Seob;Kim, Seon-Jong;Kim, Joo-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.217-224
    • /
    • 2015
  • In this paper, I describe a system for remote monitoring of devices Android-based sensor data recorded during the operation of the ballast water treatment system. The proposed remote monitoring system is Designed and implemented when a problem occurs in the ballast water treatment system installed in the vessel, provide information if you are unable to determine the cause in the field or engineer dispatch request of external. System developed is composed of a server holding the sensor data information collected from the vessel and a mobile device that is not bound to time and place. The transmission of sensor data between mobile devices and server, and is implemented by TCP/IP to transmit information securely. System is composed of request to the server from the mobile device after the user inputs the input values, to transmit the sensor data. The device provides the information of the sensor with a high level of importance to the user. Through the remote monitoring sensor information of the ballast water treatment system, the system is made to predict the failure of the sensor.

Installation and Shipboard Tests of the Ballast Water Treatment System Electro-Cleen (Electro-Cleen 선박평형수 처리장치의 실선 설치 및 선상시험)

  • Kim, Eun-Chan;Cho, Jin-Suk;Park, Yong-Seok;Lee, Jong-Wook
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.209-216
    • /
    • 2009
  • IMO has established International Convention for the Control and Management of Ships' Ballast Water and Sediment 2004 in February 2004 in order to prevent transfer of aquatic organisms through ballast water. According to the Convention, Each countries are preparing ratification and legislation process and encouraging the development of treatment system to satisfy the performance standard in the Convention. This Electro-$Cleen^{TM}$ treatment system was granted IMO basic approval in March 2006, and final approval in October 2008. The Type Approval Certificate was issued in December 2008 by the Government of Republic of Korea. This paper considers the matter of principle mechanism, overview of the system, installation on shipboard and shipboard test results for the Electro-$Cleen^{TM}$. Shipboard tests with the 8300 GT M/V Yokohama and 27,000 DWT M/V Greenwing have already been conducted. These tests confirmed that the Electro-$Cleen^{TM}$ system satisfies all of the IMO standards and is suitable for installation in new and existing ships.

  • PDF

A Comparison Study on the Sterilization Effect of Ballast Water with Cylinder Type and Groove Type (선박평형수 처리장치의 cylinder type과 groove type의 살균효과 비교 연구)

  • Kang, Ah-Young;Kim, Sang-Pil;Kim, Young-Cheol;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.616-622
    • /
    • 2015
  • Current ballast water treatment technologies are applying chemical or electrical treatment technology which are not free from secondary environmental pollution. The purpose of this study is to treat the ballast water by shear stress without an additional environmental pollution and to find out the optimal treatment apparatus. We tried to treat ballast water by applying shear stress with two different type of combination of inner and outer cylinder, such as non-pattern type and groove type. In the case of non-pattern type of inner and outer cylinder, sterilization effect was comparatively low because of a slip between inner and outer cylinder. But in the case of groove type of inner and outer cylinder, sterilization effect was superior to the non-pattern type. With a same revolutional speed of 8000rpm, an extinction effect was acquired in the gap of 1 mm of inner and outer cylinder at non-pattern type, but 3mm of that of groove type.

A study on the strategy of concerned parties with regard to the performance standards and implementation schedule of ballast water treatment systems (평형수처리장치 성능기준 및 시행시기 차이에 의한 관련 당사자들의 대응전략 연구)

  • Kim, Kyong-Min;Kim, Hoi-Jun;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • In installing ballast water treatment system, the cost of the system is high and many technical aspects are to be considered and also it takes significant time to retro-fitting on the existing ships. In addition, in the current circumstance which the Ballast Water Management Convention has not been entered into force, the 28th IMO Assembly adopted a resolution to mediate the implementation schedule of the treatment systems. In the mean time, California State and New York State have declared more stringent discharge requirements of ballast water and are planning to implement them earlier than the schedule of the Convention. In these circumstances, the implication in the difference between ballast water treatment system manufacturers and ship owners need to be considered. In this study, through the review on the considerations when installing the system onboard, stringent requirements of United States of America, and determent or mediated implementation schedules of Convention and California and New York States, the author would like to suggest the strategy of concerned parties for anticipated entrry into force of the Convention and implementation of the stringent requirements of United States of America.

Development of Marine Virus-like Particles Live/Dead Determination Method for the Performance Evaluation of Ballast Water Treatment System (선박평형수처리장치 성능 평가를 위한 해양 바이러스 생사판별 방법 개발)

  • Hyun, Bonggil;Woo, Joo-Eun;Jang, Pung-Guk;Jang, Min-Chul;Lee, Woo-Jin;Bae, Mi-Kyung;Shin, Kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.431-438
    • /
    • 2021
  • To prepare more stringent regulations for USCG Phase II ballast water management, this study investigated the staining efficiency of SYBR Green I(SGI) and SYBR Gold(SG) on the virus-like particle (VLP). A dye with high staining efficiency was applied to the treated water that was passed through the ballast water treatment system (BWTS). VLP staining was observed most clearly under the 100-fold and 200-fold dilution of the stock solution when the volume of filtered samples was 0.5 mL to 2 mL. The staining efficiency of SGI and SG did not show a significant difference. On the other hand, the green fluorescence of viruses in the sample stained with SGI was more pronounced than in the samples stained with SG (expressed yellow fluorescence), making it easier to observe. The abundance of VLP in the test water and control water treatments that did not pass through the two types of BWTS (electrolysis type, UV + electrolysis type) was approximately 109 - 1010 VLP 100 mL-1. In contrast, no stained VLP was observed in the treated water treatments. Moreover, SGI was confirmed to be effectively stained under various salinity conditions, including seawater, brackish water, and freshwater. Further verification tests and development of staining methods under various BWTS are required, but the SGI staining method is believed to be a good alternative to the VLP live/dead determination of the USCG Phase II type approval test.

A Study on the Difference in Ballasting Time Arising from the Installation of an Ultraviolet Ballast Water Management System on Existing Ships (현존선에 자외선 평형수처리장치 설치로 인한 평형수 처리시간 변화에 관한 연구)

  • Seo, Kil-Cheon;Lee, Kyoung-Woo;Rho, Beom-Seok;Cho, Ik-Soon;Lee, Won-Ju;Pham, Van Chien;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.576-585
    • /
    • 2020
  • This study quantitatively investigated the increase in ballasting time through numerical calculations when an ultraviolet (UV) ballast water management system (BWMS) is installed on an existing vessel. The calculation results indicate that the ballasting time of a gas carrier having 55,000 dead weight tonnage was 2.152 hours without installation of the UV BWMS and implementation of a flow control function. Ballasting time increased by 14.2% after installing the UV BWMS, and it increased by 20.4% with both its installation and implementation of a flow control function. If actual conditions are taken into account, ballasting time after installing the UV BWMS is estimated to increase by at least 30% compared with current ballasting time. Therefore, when concerned parties select a UV type BWMS, it is advisable for them to minimize ship operation losses from an increase in ballasting time by considering the capacity of the actual ballast pumps on board and the flow energy loss of the UV BWMS. Additionally, it is recommended that a BWMS with larger capacity, larger pipes, and pipes with inside coatings be used to minimize the increase in ballasting time after installation of the BWMS.

An Estimation of the Amount of Ship's Ballast Water to be Discharged at Korean Major Ports (국내 주요항만에서의 선박평형수 배출량 추정)

  • Choi, Hark-Sun;Kim, Han-Soo;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.284-288
    • /
    • 2009
  • The International Convention for the Control and Management of Ships Ballast Water & Sediments was adopted by consensus at a diplomatic conference of IMO at 2004. To prepare the Ballast Water Management Convention, fundamental technologies such as treatment system, type approval, risk assessment and various technical informations for formulation of the regulation for national strategy shall be developed. The information item of voyage and discharge of ship's ballast water are gathered by visiting vessel and agent at port. Using the 97 results by ships type characteristic analysis on the relation between loading/unloading and discharge/uptake of ballast water, the amounts of discharge/uptake of ballast water at each port and all of country in Korea are predicted. Hence, It is apparent that the uptake of ballast water is predicted to about 70 million ton in total of Busan, Incheon, Kwangyang and Ulsan ports at 2006 which is over 3 times than discharges.

  • PDF

A Study on the Design of Electrolysis Power for the Laboratory Test of BWTS (선박평형수 처리시스템의 랩테스트를 위한 전기분해전원 설계에 관한 연구)

  • Kim, Tae-O;Lee, Sun-Kwon;Joo, Hui-Dong;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1181-1182
    • /
    • 2011
  • 본 논문은 선박에서 발생하는 여러 해양오염원 중에서 선박평형수에서 야기되는 해양생태계의 오염 문제를 해결하기 위하여 사용되는 방법중에서 가장 효율적인 방식인 전기분해 방식에 대한 시스템 설계에 관한 연구로서, IMO의 밸러스트수 관리시스템 승인을 받기 위한 첫 번째 단계인 Basic Approval(랩테스트)을 받기 위한 전기분해 전원장치를 설계하고 시뮬레이션으로 검증하였다.

  • PDF