• Title/Summary/Keyword: 선량한도

Search Result 63, Processing Time 0.033 seconds

Estimated Additional Number of Workers and Additional Collective Dose by Reducing Dose Limits (선량한도 하향이 방사선작업인력 및 집단선량에 미치는 영향예측)

  • Ha, Chung-Woo;Na, Seong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.149-157
    • /
    • 1998
  • An analysis has been performed to estimate the additional number of workers and the additional collective dose in man-cSv which would be required, nuclear industry-wide as a result of reducing individual dose limit. This analysis can be extended to the reduction in the dose limits recommended by ICRP Publ.60 and BEIR V report as well as the proposed dose limits by regulatory authorities. An industry-wide database was employed in the analysis based on a summary of industry-wide occupational radiation exposure compiled by the Korea Radioisotope Association. Correlation model was employed to compute the affects of setting specific annual individual dose limits. In this study, we have addressed worker non-productivity while in the radiation environment on a parametric or 'sensitivity analysis' basis. This alleviates the need for developing such data underlying a summation of many individual tasks at many nuclear facilities. It has the advantage that very low non-productivity assumptions can readily be defended as conservative, in that it is difficult to approach such low worker non-productivity factors even in the best of environments in any industry. On a per facility basis, for calendar year 1997, the number of workers required would be increased from 231 workers to 269 workers and collective man-cSv dose would be also increased by approximately fourteen percent if the individual dose limit was reduced to 2 cSv/y and an individual worker non-productivity fraction of 0.1 is assumed.

  • PDF

재처리시설주변의 환경안전기술 고도화

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.7 no.9 s.55
    • /
    • pp.66-70
    • /
    • 1987
  • 방사선량이 선량한도 이내인가를 확인하는 모니터링을 위한 앞으로의 과제는 임의의 데이터 처리기능 등 데이터관리의 고도화에 있다. 일본 동경사업소의 연구는 현행모니터링의 보충조사와 고도화, 대형재처리시설의 안전평가 방법 확립에 노력하고 있다.

  • PDF

Considerations on the Concept of Dose Constraint (선량제약 개념에 대한 고찰)

  • Chang, Si-Yeong;Chung, Kyeong-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.329-338
    • /
    • 1996
  • 최근에 우리나라가 공식 회원국으로 가입한 서방 경제협력개발기구(OECD)/원자력기구(NEA) 산하의 방사선 방호 및 보건위원회(CRPPH)에서는 유럽연합(EC)의 전문가그룹과 합동으로 국제방사선방호위원회(ICRP)의 권고 60의 방사선 방호 최적화 원칙에 공식적으로 도입된 이른 바 '선량제약(dose constraint)' 개념에 대한 위원회의 논의 및 검토결과를 OECD/NEA의 공식보고서로 발간하였다. 이 보고서는 선량제약의 개념과 의미를 논리적으로 합리화하기 위하여 발간된 것이다. 선량제약이란 용어와 개념은 새로워 보이지만 실상은 전혀 새로운 것이 아니다. 우리나라에서도 방사선 방호의 실무현장에서 용어나 의미는 조금 다르다 할 수 있어도 이 개념을 부분적으로 적용해왔다고 할 수 있다. 예를 들어, 선량한도 이하의 낮은 선량으로 작업자의 피폭을 제한하기 위하여 도입된 '연간 선량목표치' 또는 '방사성 물질의 방출목표관리치' 등이 여기에 해당될 것이다. 따라서, OECD/NEA의 공식보고서를 번역한 이 해설논문이 국내의 방사선 방호분야에서 활약하고 있는 정책 입안자, 연구자, 규제업무자, 방사선 관리실무자 등 방사선 방호 업무분야의 관련자들에게 도움이 되었으면 한다.

  • PDF

협회소식

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.4 s.52
    • /
    • pp.2-4
    • /
    • 2001
  • PDF

협회동정

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.8 s.56
    • /
    • pp.2-2
    • /
    • 2001
  • PDF

Assessment of Radiation Dose Due to X-Ray Simple Series Examinations (X-선 단순 Series 촬영 시 피폭 선량 평가)

  • Gang, Eunbo;Hwang, Incheol;Shin, Woonjae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • In diagnostic radiology, each part is examined through serial radiography in most cases of general radiography. However, the reality is that, as for diagnostic reference level, measured values have been set up only for AP projection of each part and lateral projection. In the clinical setting, cumulative dose is incurred by serial radiography of patients, and this can make comparison of diagnostic reference level and cumulative exposure dose impossible or can lead to underestimation of diagnostic reference level. In this study, measurement of cumulative dose of serial radiography of each part revealed that when converting entrance surface dose to effective dose in case it is included in the exposure field, cumulative dose measured from a maximum of 38.06% to a minimum of 0.23% of individual dose limitation of the public. Also, when converting entrance surface dose of each part that is not included in the exposure field into effective dose, it measured from a maximum of 5% to a minimum of 0.04% of individual dose limitation of the public. Results of this study show entrance surface dose substantially increases in serial radiography of each part. Therefore, it is deemed that hospitals need to establish diagnostic reference level specifically, and subdivision of radiography orders for patients is also required in order to reduce unnecessary inspections. Moreover, the need of accurate exposure field is emphasized in case of inspection of several parts.

방사선감시기 경보설정치 산정에의 ICRP-60 권고안 적용

  • 배영직;이승종;이경희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.683-690
    • /
    • 1998
  • 국내의 원자력 관계법령은 1965년에 발표된 ICRP-9 권고안에 기초하고 있다. 그러나, 최근 국내 규제기관에서는 ICRP-60 권고안을 수용하는 새로운 방사선량 체계 및 한도등을 포괄한 원자력관계법령 개정 최종(안)을 마련하였고 이를 곧 시행할 예정임에 따라 현행 법령이 적용된 원자력시설의 설계 및 운영에 있어서는 적지않은 변경이 불가피하다. 본 논문에서는 이로인한 영향중의 하나로 ICRP-60 권고안을 적용하여 설계중인 신규원전의 기체유출물 방사선감시기에 대한 경보설정치를 산정하였으며, 비교를 위해 현행 법령이 적용된 기존원전에 대한 경보설정치 산정방법을 소개하였다. 이와함께 기존원전에 사용된 DRL (Dose Rate Limit, 선량률한도) 방식과 이를 보다 효과적으로 개선한 ECL (Effluent Concentration Limit, 방출농도한도) 방식을 소개하였으며, 각각의 방식에 의해 산정된 경보설정치를 상호 비교하여 ECL 방식의 효율성과 정확성을 입증코자 하였다. 마지막로는 국내 원전에 설치, 가동중인 기체유출물 방사선감시기에 대해 개정될 국내 법령의 적용과 보다 정확한 경보설정치 산정을 위한 작업이 수행되어야 할 것이며. 이러한 결과가 계통에 반영되어 운전되어야할 것임을 제안하였다.

  • PDF