• Title/Summary/Keyword: 선량조절

Search Result 306, Processing Time 0.031 seconds

Radiation Effect on NO, NOS and TGF-$\beta$ Expressions In Rat Lung (쥐의 폐에서 방사선이 Nitric Oxide (NO), Nitric Oxide Synthase (NO) 및 TGF- $\beta$의 발현에 미치는 영향)

  • Oh Young-Taek;Park Kwang-Joo;Kil Hoon-Jong;Ha Mahn Joon;Chun Mison;Kang Seung-Hee;Park Seong-Eun;Chang Sei-Kyung
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.321-328
    • /
    • 2000
  • Purpose :NOS2 induce NO Production and NO activate TGF-${\beta}$. The TGF-${\beta}$ is a inhibitor of NOS2. If this negative feedback mechanism operating in radiation pneumonitis model, NOS2 inhibitor may play a role in TGF-${\beta}$ suppression. We planned this study to evaluate the expression patterns of NO, NOS2 and TGF-${\beta}$ in vivo radiation pneumonitis model. Materials and Methods : Sixty sprague-Dawley rat were irradiated 5 Gy or 20 Gy. They were sacrificed 3, 7, 14, 28 and 56 days after irradiation. During sacrifice, we peformed broncho-alveolar lavage (BAL). The BAL fluids were centrifuged and supernatents were used for measure NO and TGF-${\beta}$, and the cells were used for RT-PCR. Results : After 5 Gy of radiation, NO in BAL fluid increased at 28 days in both lung and TGF-${\beta}$ in left lung at 56 days. NO increased in BAL fluid at 28 days in both lung after irradiation and TGF-${\beta}$ in right lung at 28-56 days after 20 Gy of radiation. After 5 Gy of radiation, NOS2 expression was increased in right lung at 14 days, in both lung at 28 days and in left lung at 56 days. TGF-${\beta}$ expression was reduced in both lung at 28 days and increased in left lung at 56 days. Conclusions :The Proposed feedback mechanism of NO, NOS2 and TGF-${\beta}$ was operated in vivo radiation pneumonitis model. At 56 days, however, NOS2 and TGF-${\beta}$ expressed concurrently in left lung after 5 Gy and in both lung after 20 Gy of radiation.

  • PDF

Effect of Gamma Irradiation for Hygienic Long-Term Storage on Biological Activity of Teucrium veronicoides (위생적인 장기 보존을 위한 감마선 조사가 곽향(Teucrium veronicoides)의 생리활성에 미치는 영향)

  • Park, Hye-Jin;Park, Ki-Tae;Cho, Young-Je
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.5
    • /
    • pp.581-591
    • /
    • 2017
  • The purpose of this study was to examine the biological activities of gamma-irradiated Teucrium veronicoides. In photostimulated luminescence analysis, non-irradiated sample showed lower than 700 photon counts (PCs), whereas irradiated (5 and 10 kGy) samples showed higher than 700 PCs. The thermoluminescence ratio of non-irradiated samples was less than 0.1, whereas the values of irradiated samples were greater than 0.1. Electron spin resonance analysis was performed confirmed for irradiation identification. The total phenolic contents of hot-water and 50% ethanol extracts were higher than those values after irradiation at 10 kGy. Regarding 1,1-diphenyl-2-picrylhydrazyl radical inhibitory activity, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) radical scavenging activity, antioxidant protection factor, thiobarbituric acid reactive substance inhibitory activity as antioxidant test and xanthine oxidase inhibitory activity, the effect of gamma irradiation had on significant effects. On the other hand, ${\alpha}-amylase$ inhibitory activity of 10 kGy-irradiated hot-water extract was 23.6% higher than that of the non-irradiated sample. Thus, gamma irradiation could be used for the long-term storage of Teucrium veronicoides.

The Results of Postoperative Radiotherapy for Hypopharyngeal Carcinoma (하인두암 환자에서의 수술 후 방사선치료의 결과)

  • Kim Won Taek;Ki Yong Kan;Nam Ji Ho;Kim Dong Won;Lee Byung Ju;Wang Su Gun;Kyuon Byung Hyun
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.254-264
    • /
    • 2004
  • Purpose: This study was carried out to confirm clinical values and limitations of postoperative radiotherapy for hypopharyngeal carcinoma, to evaluate various prognostic factors which may affect to the treatment results and to use these results as fundamental data for making a new treatment strategy. Methods and Materials:. A retrospective analysis was peformed on 64 previously untreated patients with squamous cell carcinoma of the hypopharynx, seen between 1988 and 1999 at Pusan National University Hospital. Most of patients were treated by laryngopharyngectomy and neck dissection followed by conventional fractionated postoperative radiotherapy on surgical bed and cervical nodal areas. Results: The five-year overall survival rate and cause-specific survival rate were 42.2 percent and 51.6 percent, respectively. Univariate analysis of various clinical and pathologic factors confirmed the overall stage, TN-stage, secondary primary cancers, surgical positive margin, nodal extracapsular extension, total radiation doses as significant prognostic factors of hypopharyngeal carcinomas. But in multivariate analysis, TN-stage, surgical positive margin and extracapsular extesion were only statistically significant. Conclusion: In resectable cases of hypopharyngeal carcinoma, combined surgery and postoperative radio-therapy obtained good treatement results, even though sacrificing the function of larynx and pharynx. But in advanced and unresectable cases, with respect to survivals and qualify of life issues, we were able to confirm some limitations of combined therapy. So we recommend that comparative studies of recent various chemo-radiotherapy methods and advanced radiotherapy techniques with these data should be needed.

Role of Postoperative Radiotherapy for Patients with Pathological Stage III Non-Small-Cell Lung Cancer after Curative Resection (근치적 절제술 후 병기3의 비소세포성 폐암에서 수술 후 방사선 치료의 역할)

  • Kim, Mi-Young;Wu, Hong-Gyun;Kim, Hak-Jae;Heo, Dae-Seog;Kim, Young-Whan;Kim, Dong-Wan;Lee, Se-Hoon;Kim, Joo-Hyun;Kim, Young-Tae;Kang, Chang-Hyun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.44-52
    • /
    • 2011
  • Purpose: To evaluate the outcomes and prognostic factors of postoperative radiotherapy (PORT) for patients with pathological stage III non-small-cell lung cancer (NSCLC) at a single institution. Materials and Methods: From 2000 to 2007, 88 patients diagnosed as having pathologic stage III NSCLC after curative resection were treated with PORT. There were 80 patients with pathologic stage IIIA and eight patients with pathologic stage IIIB in the AJCC 6th staging system. The majority of patients (n=83) had pathologic N2 disease, and 56 patients had single station mediastinal LN metastasis. PORT was administered using conventional technique (n=76) or three-dimensional conformal technique (n=12). The median radiation dose was 54 Gy (range, 30.6 to 63 Gy). Thirty-six patients received chemotherapy. Radiation pneumonitis was graded by the Radiation Therapy Oncology Group system, and other treatment-related toxicities were assessed by CTCAE v 3.0. Results: Median survival was 54 months (range, 26 to 77 months). The 5-year overall survival (OS) and disease free survival (DFS) rates were 45% and 38%, respectively. The number of metastatic lymph nodes was associated with overall survival (hazard ratio, 1.037; p-value=0.040). The 5-year locoregional recurrence free survival (LRFS) and distant metastasis free survival (DMFS) rates were 88% and 48%, respectively. Multiple stations of mediastinal lymph node metastasis was associated with decreased DFS and DMFS rates (p-value=0.0014 and 0.0044, respectively). Fifty-one relapses occurred at the following sites: 10 loco-regional, 41 distant metastasis. Grade 2 radiation pneumonitis was seen in three patients, and symptoms were well tolerated with anti-tussive medication. Grade 2 radiation esophagitis was seen in 11 patients. There were no grade 3 or more severe complications associated with PORT. Conclusion: Our retrospective data show that PORT for pathological stage III NSCLC is a safe and feasible treatment and could improve loco-regional control. The number of metastatic lymph nodes and stations of mediastinal lymph node metastasis were analyzed as prognostic factors. Furthermore, efforts are needed to reduce distant metastasis, which is a major failure pattern of advanced stage NSCLC.

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Study of the Difference in Residual Amounts according to the Method of Securing Intravenous Injections and the Dose of Physiological Saline during 18F-FDG Administration (18F-FDG 투여 시 정맥주사 확보 방법 및 생리식염수 용량에 따른 잔류량의 차이에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • This study compares the difference between the remaining amount in syringes according to injection method and the dose of physiological saline when the radiopharmaceutical 18F-FDG isotope is injected into patients who visited the hospital for PET examination. After performing a CT or MRI using a contrast medium when 18F-FDG was injected into 40 patients who came to the hospital for PET examination without removing the 3-way, the radioactivity remaining in the syringe and the 3-way was measured and the dose of radioactivity confirmed. At this time, 20 patients were divided into different dose groups of physiological saline. Another injection method was used to compare the remaining amount of the syringe and the difference in the remaining amount according to the amount of physiological saline when the injection was performed with an extension. After an injection of 18F-FDG, the actual administered dose was confirmed by measuring the radioactivity remaining in the syringe and the 3-way or extension with a calibrator. As a result of measuring the radioactivity of the syringe before administering the radiopharmaceutical and the radioactivity of the syringe and the 3-way or extension after administration, the 3-way injection method in 10 cc's of physiological saline had the lowest residual amount. The remaining amount increased in the order of the extension to 10 cc's of saline and the 3-way to 5 cc's of saline. Likewise, the 5 cc's saline solution and the extension injection method demonstrated the highest residual amounts. The residual difference with the lowest level of remaining injection method was found to be 0.053 mCi. It was found that in a PET examination, by considering the radioactivity remaining in the 3-way and extension and by adjusting the dose of physiological saline, if the intended dose to be administered to the actual patient is determined, it is possible to administer the radiopharmaceutical to the patient more accurately.