• Title/Summary/Keyword: 선량률 효과

Search Result 90, Processing Time 0.041 seconds

Dose-Rate Effects Generated from Repair and Regeneration (재생과 증식에 기인하는 선량률 효과)

  • Yi Pon Nyong;Cho Kwan Ho;Marks Richard D.;Kim Jae Ho
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.171-183
    • /
    • 1989
  • A general effect for cell proliferation has been incorporated into Roesch's survival equation (Accumulation Model). From this an isoeffect formula for the low dose-rate regimen is obtained. The prediction for total doses equivalent to 60Gy delivered at the constant dose-rate over 7 days agrees well with the dose-time data of Paterson and of Green, when the parameter ratio A/B (${\approx}{\alpha{\mu}}/2{\beta}\;where\;{\mu}$ is the repair rate) is chosen to be 0.7Gy/h. When a constant proliferation rate and known facts of division delay are assumed, an isoeffect relation between low dose-rate treatment and acute dose-rate treatment can be derived. This formula in the regimens where proliferation is negligible predicts exactly the data of Ellis that 8 fractions of 5 Gy/day for 7 days are equivalent to continuously applied 60Gy over 7days, provided the A/B ratio is 0.7 Gy/h and the $\alpha/\beta$ ratio is 4Gy. Overall agreement between the clinical data and the predictions made by the formula at the above parameter values suggests that the biologcal end points used as the tolerance level in the studies by Paterson, Green, and Ellis all agree and they are not entirely the early effects as generally assumed. The absence of dose-rate effects observed in the mouse KHT sarcoma can better be explained in terms of a large value for the A/B ratio. Similarly, the same total dose used independently of the dose-rate to treat head and neck tumors by Pierquin can be justified.

  • PDF

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems (광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2287-2292
    • /
    • 2012
  • In this study, $Co^{60}$ gamma-ray induced loss on Ge-doped single mode (SM) fiber has been measured. Gamma-ray is irradiated for 4 hours at the dose rate of 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur significantly. Furthermore, dose rate effect was observed, that dose rate using the same total dose increased higher, then optical fiber loss increased more. Also annealing effect was observed, that the loss after irradiation, increased higher, then the recovery rate of loss was increased. This results are foreseen to be base data in the future radiation-hardened optical fiber study.

The Dose Characteristics of Designed Ir-192 Micro-source for Brachytherapy (근접조사용 Ir-192 마이크로선원의 디자인과 선량 특성)

  • 최태진;김진희
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.81-89
    • /
    • 2003
  • The dose distributions of designed Ir-192 micro-source were investigated by dose computations which were accomplished by employing shape of encapsule material and thickness of the source for self-absorption. The computation dose derived from air-kerma rate (S$_{k}$ ) and dose rate constant (Λ) includes the anisotropy of dose distribution around the source. We got the dose rate constants in a water medium is 1.154 cGy h$^{-1}$ U$^{-1}$ . The size of the source was 0.5 mm in diameter and 3.5 mm in length and it was encapsuled in 1.1 mm$\Phi$${\times}$5.5 mm of stainless steel sealed with 0.3 mm of filter thickness. The tissue dose of reference point at 1.0 cm radial distance of the source axis was delivered 1.154 Uh$^{-1}$ (1.3167${\times}$10$^{-3}$ cGy/mCi-sec) from the S$_{k}$ 4.108U/mCi of Ir-192 source. The filtration effect contributed to air-kerma strength as exponential filtering effect of 86.2% in total attenuation, but self-absorption was 88.4% from radial dose distributions. In particular, the dose attenuations showed a rapid anisotropic distributions as 56% of reference dose along to $\pm$10 degrees from the tip of source axis and 50% for of that to source-cable direction. We persist in use the large diameter of applicator will avoid the dose anisotropy by the filtered attenuation effects along the axis of Ir-192 micro-source.

  • PDF

The Analysis of Radiation Effects of Single-Mode Optical Fibers Using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 단일모드 광섬유의 방사선 영향 분석)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Kim, Young-woong;Han, Won-Taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.732-735
    • /
    • 2013
  • In this study, we are measured gamma-ray induced loss on single-mode (SM) fibers from a total of four different manufactures. The $Co^{60}$ gamma-ray source was used in this test. The gamma-ray is irradiated for 2 hours at the dose rate of 0.6 kGy/hr, 1.2 kGy/hr, 2.4 kGy/hr. In test results, We clearly confirm the dose rate effect in different fiber types and evaluate the radiation sensitivity by the change of the radiation-induced loss.

  • PDF

A Study on the Radiation Source Effect to the Radiation Shielding Analysis for a Spent-Fuel Cask Design with Burnup-Credit (연소도이득효과를 적용한 사용후핵연료 수송용기의 방사선원별 차폐영향 분석)

  • Kim, Kyung-O;Kim, Soon-Young;Ko, Jae-Hoon;Lee, Gang-Ug;Kim, Tae-Man;Yoon, Jeong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • The radiation shielding analysis for a Burnup-credit (BUC) cask designed under the management of Korea Radioactive Waste Management Corporation (KRMC) was performed to examine the contribution of each radiation source affecting dose rate distribution around the cask. Various radiation sources, which contain neutron and gamma-ray sources placed in active fuel region and the activation source, and imaginary nuclear fuel were all considered in the MCNP calculation model to realistically simulate the actual situations. It was found that the maximum external and surface dose rates of the spent fuel cask were satisfied with the domestic standards both in normal and accident conditions. In normal condition, the radiation dose rate distribution around the cask was mainly influenced by activation source ($^{60}Co$ radioisotope); in another case, the neutron emitted in active fuel region contributed about 90% to external dose rate at 1m distance from side surface of the cask. Besides, the contribution level of activation source was dramatically increased to the dose rates in top and bottom regions of the cask. From this study, it was recognized that the detailed investigation on the radiation sources should be performed conservatively and accurately in the process of radiation shielding analysis for a BUC cask.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF

High versus Low Dose-Rate Intracavitary Irradiation for Adenocarcinoma of the Uterine Cervix (자궁경부 선암 환자에서 고선량률 강내치료와 저선량률 강내치료의 비교)

  • Kim Woo Chul;Kim Gwi Eon;Chung Eun Ji;Suh Chang Ok;Hong Soon Won;Cho Young Kap;Loh JK
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.32-39
    • /
    • 2000
  • Purpose :The incidence of adenocarcinoma of the uterine cervix is low. Traditionally, Low Dose Rate (LDR) brachytherapy has been used as a standard modality in the treatment for patients with carcinoma of the uterine cervix. The purpose of this report is to evaluate the effects of the High dose rate (HDR) brachytherapy in the patients with adenocarcinoma of the uterine cervix compared with the LDR. : From January 1971 to December 1992, 106 patients of adenocarcinoma of uterine cervix were treated with radiation therapy in the Department of Radiation Oncology, Yonsei University with curative intent. LDR brachytherapy was carried out on 35 patients and 71 patients were treated with HDR brachytherapy. In LDR Group, 8 patients were in stage I, 18 in stage II and 9 in stage III. External radiation therapy was delivered with 10 MV X-ray, daily 2 Gy fractionation, total dose 40$\~$46Gy (median 48 Gy). And LDR Radium intracavitary irradiation was peformed with Henschke applicator, 22$\~$59 Gy to point A (median 43 Gy). In HDR Group, there were 16 patients in stage 1, 38 in stage II and 17 in stage III. The total dose of external radiation was 40$\~$61 Gy(median 45 Gy), daily 1.8$\~$2.0 Gy. HDR Co-60 intracavitary irradiation was peformed with RALS (Remote Afterloading System), 30 $\~$ 57 Gy(median 39 Gy) to point A, 3 times a week, 3 Gy per fraction. Conclusion : The 5-year overall survival rate in LDR Group was 72.9$\%$, 61.9$\%$, 45.0$\%$ in stage I, II, III, respectively and corresponding figures for HDR were 87.1$\%$, 58.3$\%$, 41.2$\%$, respectively (p>0.05). There was no statistical difference in terms of the 5-year overall survival rate between HDR Group and LDR Group in adenocarcinoma of the uterine cervix. There was 11$\%$ of late complication rates in LDR Group and 27$\%$ in HDR Group. There were no prognostic factors compared HDR with LDR group. The incidence of the late complication rate in HDR Group stage II, III was higher than that in LDR Group(16.7$\%$ vs. 31.6$\%$ in stage II, 11.1$\%$ vs. 35.3$\%$ In stage III, p>0.05). Although the incidence of radiation induced late complication rate was higher in HDR Group stage II and III patients than that in the LDR Group, statistical significance was not detected and within acceptable level. Conclusion : There was no difference in terms of 5-year survival rate and failure pattern in the patients with adenocarcinoma of the uterine cervix treated with HDR and LDR brachytherapy. Even late complication rates were higher in the HDR group It was an acceptable range. This retrospective study suggests that HDR brachytherapy seems to replace the LDR brachytherapy in the adenocarcinoma of the uterine cervix. However, further studies will be required to refine the dose rate effects.

  • PDF

Dose Computation Modeling for Frustum Typed Ir-192 of Ralstron Source (Ralstron 선원대체형 Ir-192 원추선원의 선량 전산화 모델링)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.19-29
    • /
    • 2001
  • In dose modeling, the shape of actual source and sealed capsule are important parameter to determine the physical dose computation. The author investigated the effect of filter of source self-absorption and sealed capsule to designed the high dose rate Ir-192 source for Ralstron(Japan) unit. The size of source designed to 1.5 mm $\Phi$ x 1.5mm length of actual source sealed with stainless steel which is 3.0mm $\Phi$ x 12.0mm length connected to driving cable. The dose attenuation was derived 66.3 % from 2655 segmented source at reference point of 10mm lateral distance of source. The output dose rate factor in tissue for designed source showed 0.0013511 cGy/mCi-sec in reference point at 1cm lateral distance of source center. The dose distribution at inferior of source showed the 52% of that of source tip region, however, the filtering effect was small as 4% at 45degrees of source axis. The dose attenuation within 20 degrees of source axis at near source-cable connector showed large filtering effect as 40% over, but the small effect was revealed isotropic dose distribution at large angle.

  • PDF

Radiation-Induced Grafting of Acrylic Acid onto Polypropylene Fabric in the Presence of Metallic Salt (폴리프로필렌 부직포에 아크릴산의 방사선 그라프트 반응에서 금속염의 효과)

  • Nho, Young Chang;Park, Jong Shin;Jin, Joon-Ha
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.946-953
    • /
    • 1996
  • The effect of absorbed dose, dose rate, cationic salts and solvent on the grafting yield was evaluated when acrylic acid was grafted onto polypropylene fabric by simultaneous irradiation process. Low dose rate when irradiated with the same absorbed dose led to a high grafting yield. On the other hand, the grafting yield increased with dose rate in case the total irradiation times is equal, and the initial rate of grafting was found to be proportional to be 0.74 power of dose rate. $FeSO_4{\cdot}7H_2O$ was found to be the most effective additive for high grafting yield, while inhibiting homopolymer formation. It was impossible to induce radiation grafting without the addition of the certain amount of salt, but the grafting yield decreased with increasing metallic salt.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF