• Title/Summary/Keyword: 선량계산

Search Result 721, Processing Time 0.034 seconds

A Study on the Skin Dose Measurement of Glass Dosimeter Use During Rectal Cancer 3field Technic and Cervical Cancer 4field Technic Radiation Therapy (직장암 3문조사와 자궁경부암 4문조사 방사선 치료 시 유리선량계를 이용한 피부선량 측정에 관한 연구)

  • Shin, Seong-Soo;Choi, Won-Sik;Park, Cheol-Soo;Lee, Sun-Yeb;Cho, Jae-Hwan;Seo, Jeong-Min;Shim, Jae-Koo;Kim, Chan-Hyeong;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • Recently a variety of high technologies for radiation therapy (IMRT, SRS,. 3D-RT, etc.) has been developed. For the cervical and rectal cancer, 3field or 4field radiotherapy have been applied to the patients. In the case of two-dimensional treatment, one of the most typical side-effects is skin burn due to the radiation irradiation. In general the skin dose is evaluated by only a single measurement during the whole treatment period. In this study, however, skin dose was measured in each radiation treatment and the total skin dose was accumulated in a glass dosimeter through all the cases. After simulating the skin dose from treatment planning system, the results were compared with the actual skin doses. The results showed a good agreement between two data sets. Even though there are certain amount of errors caused by the patient movement along the treatment, the difference between actual dose and simulated dose was within the accepted range of error.

Rapid Optimization of Multiple Isocenters Using Computer Search for Linear Accelerator-based Stereotactic Radiosurgery (Multiple isocenter를 이용한 뇌정위적 방사선 수술시 컴퓨터 자동 추적 방법에 의한 고속의 선량 최적화)

  • Suh Tae-suk;Park Charn Il;Ha Sung Whan;Yoon Sei Chul;Kim Moon Chan;Bahk Yong Whee;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.109-115
    • /
    • 1994
  • The purpose of this paper is to develop an efficient method for the quick determination of multiple isocenters plans to provide optimal dose distribution in sterotactic radiosurgery. A Spherical dose model was developed through the use of fit to the exact dose data calculated in a 18cm diameter of spherical head phantom. It computes dose quickly for each spherical part and is useful to estimate dose distribution for multiple isocenters. An automatic computer search algorithm was developed using the relationship between the isocenter move and the change of dose shape, and adapted with a spherical dose model to determine isocenter separation and cellimator sizes quickly and automatically. A spheric81 dose model shows a comparable isodose distribution with exact dose data and permits rapid calculations of 3-D isodoses. the computer search can provide reasonable isocenter settings more quickly than trial and error types of plans, while producing steep dose gradient around target boundary. A spherical dose model can be used for the quick determination of the multiple isocenter plans with 3 computer automatic search. Our guideline is useful to determine the initial multiple isocenter plans.

  • PDF

Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

Monte Carlo Calculation of Thermal Neutron Flux Distribution for (n, v) Reaction in Calandria (몬테칼로 코드를 이용한 중수로 Calandria에서의 $(n,\;{\gamma})$ 반응유발 열중성자속분포 계산)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Kyo-Youn
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.13-22
    • /
    • 1994
  • The MCNP 4.2 code was used to calculate the thermal neutron flux distributions for $(n,\;{\gamma})$reaction in mainshell, annular plate, and subshell of the calandria of a CANDU 6 plant during operation. The thermal neutron flux distributions in calandria mainshell, annular plate, and subshell were in the range of $10^{11}{\sim}10^{13}\;neutrons/cm^2-sec$ which is somewhat higher than the previous estimates calculated by DOT 4.2 code. As an application to shielding analysis, photon dose rates outside the side and bottom shields were calculated. The resulting dose rates at the reactor accessible areas were below design target, $6 {\mu}Sv/h$. The methodology used in this study to evaluate the thermal neutron flux distribution for $(n,\;{\gamma})reaction$ can be applied to radiation shielding analysis of CANDU 6 type plants.

  • PDF

Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF

Calculation of Internal Exposure Dose in Korean Man Resulting from Single and Chronic Intake of Tritium (트리튬($^{3}H$)의 단일(單一) 및 만성섭취(晩性攝取)에 대한 한국인(韓國人)의 내부피복(內部被曝) 선량(線量) 계산(計算))

  • Kim, Jang-Lyul;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.8-14
    • /
    • 1983
  • The doses to Korean adult by a single and chronic intake of tritiated water are determined using a three compartment model, which describes the retention of tritium radionuclide in body water and in bound organic form in the body. The results show that the total dose of a single intake, using retention half-time for the three-compartment of 9, 30, and 450 days, is 17.64 mrads ($176.4{\mu}Gy$) per 1mCi/kg ($3.7{\times}10^7Bq/kg$) intake, 97% of which is due to tritium in body water and 3% to bound tritium in tissue. In the chronic intake of 1mCi/day($3.7{\times}10^7Bq/day$) tritiated water, the total dose is 85.5 mrad/day(0.855mGy/day). Furthermore, in this study (MPC) a and (MPC)w values of tritium for Korean man are calculated by using the modified formula originated from ICRP Publication-2. From the results, we found that the (MPC) a, w values of ICRP underestimated approximately 50%, the (MPC)a, w values of Korean man must be elevated as high as approximately 50% than that of ICRP.

  • PDF

Transmission Dose Estimation Algorithm for in vivo Dosimertry (투과선량을 이용한 생체내 (in vivo) 선량측정을 위한 알고리즘)

  • Yun, Hyong-Geun;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Kim, Si-Yong;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.147-154
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 co Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed lot estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Determination of the exposure conversion coefficient for 3" X 3" NaI spectrum (3" X 3" NaI 스펙트럼의 조사선량 변환계수 결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.73-78
    • /
    • 2001
  • In order to find the exposure conversion coefficients for 3"X3" NaI spectrum, we measured the exposure rates with the pressurized ion chamber at 29 different areas in the range of $4{\sim}23{\mu}R\;h^{-1}$, and also measured the gamma spectra with 3"X3" and 4"X4" NaI detectors, simultaneously. The exposure conversion coefficient of the total energy method was determined using the linear relation between the measured exposure rate and the gamma spectrum energy. In order to find the exposure conversion coefficients of the energy band method, we applied the exposure conversion coefficients recommended by NCRP to the 4"X4" NaI spectra, and calculated the exposure rates due to $^{40}K,\;^{238}U$, and $^{232}Th$ series respectively. Using the linearly proportional relation between the obtained $^{232}Th$ series exposure rate and peak area of 2614 keV that represents the $^{232}Th$ series, we obtained the exposure conversion coefficients for $^{232}Th$ series. We also determined the conversion coefficients for $^{238}U$ series and $^{40}K$ using a similar method.

  • PDF

The Feasibility Study on the Direct Use of the MC-derived Physical Quantities to Determine the Model Parameters of RTPS with -Model-Based Photon Dose Calculation Algorithm (모델기반 광자선량 계산방식을 사용하는 전산화치료계획장치의 모델변수 결정에 있어 몬테카를로 모사법에 의해 유도된 방사선 물리량의 직접 적용 가능성에 대한 연구)

  • 강세권;박희철;배훈식;조병철
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2004
  • The commissioning of a model-based treatment planning system requires many parameters to fit the measured depth doses and transverse profiles. For the commissioning of the Pinnacle$^3$ system, through the Monte Carlo (MC) simulation, the necessary parameters, including the photon spectrum, contaminant electrons, off-axis softening and fluency of photons, were observed. Through the simulation the parameters contained valuable information, but the calculated results of the Pinnacle$^3$ using the MC-derived parameters showed discrepancies with those measured for the off-axis softening and the fluency of photons. Even though the MC calculation produces reasonable values for the commissioning, the thorough physical basis of the Pinnacle$^3$'s commissioning process is needed in order to directly use the MC derived parameters.

  • PDF