Purpose : A ginkgo biloba extract (GBE) has been known as a hypoxic cell radiosensitizer. Its mechanisms of action are increase of the red blood cell deformability, decrease the blood viscosity, and decrease the hypoxic cell fraction in the tumor. The aims of this study were to estimate the effect of GBE on fractionated radiotherapy and to clarify the mechanism of action of the GBE by estimating the blood flow in tumor and normal muscle. Materials and Methods : Fibrosarcoma (FSall) growing in a C3H mouse leg muscle was used as the tumor model. When the tumor size reached 7 mm in diameter, the GBE was given intraperitoneally at 1 and 25 hours prior to irradiation. The tumor growth delay was measured according to the various doses of radiation (3, 6, 9, 12 Gy and 15 Gy) and to the fractionation (single and fractionated irradiation) with and without the GBE injection. The radiation dose to the tumor the response relationships and the enhancement ratio of the GBE were measured. In addition, the blood flow of a normal muscle and a tumor was compared by laser Doppler flowmetry according to the GBE treatment. Results : When the GBE was used with single fraction irradiation with doses ranging from 3 to 12 Gy, GBE increased the tumor growth delay significantly (p<0.05) and the enhancement ratio of the GBE was 1.16. In fractionated irradiation with 3 Gy per day, the relationships between the radiation dose (D) and the tumor growth delay (TGD) were TGD $(days)=0.26{\times}D$ (Gy)+0.13 in the radiation alone group, and the TGD $(days)=0.30{\times}D$ (Gy)+0.13 in the radiation with GBE group. As a result, the enhancement ratio was 1.19 ($95\%$ confidence interval; $1.13\~1.27$). Laser Doppler flowmetry was used to measure the blood flow. The mean blood flow was higher in the muscle (7.78 mL/100 g/min in tumor and the 10.15 mL/100 g/min in muscle, p=0.005) and the low blood flow fraction (less than 2 mL/100 g/min) was higher in the tumor $(0.5\%\;vs.\;5.2\%,\;p=0.005)$. The blood flow was not changed with the GBE in normal muscle, but was increased by $23.5\%$ ( p=0.0004) in the tumor. Conclusion : Based on these results, it can be concluded that the GBE enhanced the radiation effect significantly when used with fractionated radiotherapy as well as with single fraction irradiation. Furthermore, the GBE increased the blood flow of the tumor selectively.
The oxidizing species are generated from the radiolysis of groundwater in the pore of buffer material around the canister used for the disposal of spent fuels. A mathematical model was introduced to calculate the cathodic current density induced by the oxidant around the canister, which determined the corrosion of carbon steel. An analytical solution was derived to get the cathodic current density in the cylindrical coordinate. The cathodic current densities from both the rectangular coordinate and cylindrical coordinate were compared with each other. The source terms and absorbed dose rate for the calculation of the radiolysis were calculated using the ORIGEN2 and MCNP computer code, respectively. The radius of the canister was determined with the new model in order to prevent the local corrosion. The results showed that the new solution made the cathodic current density around 25 % lower than the Marsh model.
The Korean rice of Paldal variety was milled, in March, 1969, into brown rice and 92% polished one and each 1.5kg sample was packed in the kraft paper bags. With Co-60 gamma-irradiation, the samples were treated in the various ranges of 500, 800 and 1,000 Krad, and then they were stored at the room temperature. The changes of the contents of free amino acids in the samples were determined by the amino acid autoanalyzer (Yanagimoto, Japan, LC-type). The results obtained in June and October of the year were as follows. 1) In the disinfecting irradiation of rice by the higher doses of 500, 800 and 1,000 Krad, there wasn't any particular distinction between the control lot and irradiated lot in respect to the free amino acid contents. 2) The contents of free amino acids in rice during storage had the decreasing tendencies, and especially prominent in case of glutamic acid.
X-ray device used in the diagnosis has made possible to have more effective and accurate diagnosis, powered by the development of various devices. Based on this, X-ray device has become the most basic and essential diagnostic equipment in clinical medicine. At present, in the image acquisition field using X-ray, the use of Digital radiography which is useful in the acquisition time reduction and transfer of images and is possible to have the dose reduction has expanded. With the structure using one detector, this DR device has disadvantages in that it needs structural changes unlike existing X-ray and the detector should be moved to the desired position depending on the shooting location. Therefore, in this study, using BLDC(Brushless direct current) motor and PID(Proportional integral differential) control method, the automatic control system of 3-axis which is upward and downward, left and right and rotation of detector where having the most movement in DR was designed and produced and its performance was evaluated.
Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
/
v.7
no.1
/
pp.17-23
/
2009
Dihexyloctanamide(DHOA) was used as an extractant or phase modifier with the diamide extractants in a solvent extraction process for a radioactive liquid waste treatment. The degradation compounds of the DHOA extractant, irradiated with $^{60}Co$ gamma ray, were octanoic acid and dihexylamine which are identified by a Fourier transform infrared(FT-IR) and gas chromatograph/mass spectrometer(GC/MS) analysis, and determined by the GC/MS with selected ion monitoring(SIM) mode. Retention behavior of octanoic acid, tridecane (internal standard) and dihexylamine in total ion chromatogram (TIC) were 8.65 min., 9.79 min., and 10.27 min., respectively. With increasing the absorbed dose of the $\gamma$-ray irradiated DHOA, the concentration of octanoic acid was decreased and that of dihexylamine was increased.
Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.
Cho In-Hee;Kwak Noh-Seok;Kang Phil-Hyun;Nho Young-Chang;Hwang Taek-Sung
Polymer(Korea)
/
v.30
no.3
/
pp.217-223
/
2006
Ion exchange fibers, high functionalized onto hybrid polyolefine fiber's surface, were synthesized by $\gamma-ray$ mutual radiation. Degree of grafting (DG) of copolymer increased with increasing GMA monomer concentration and the maximum rate of DG was 355% at 50 GMA. The graft reaction occurred in polar solvent and DG was 190% maximum value in $1.0\times10^{-3}$ Mohr's salt and 0.1 M sulfuric acid, respectively. The amination for graft copolymers varied depending on amine reagents, and the reactivity for copolymers was highest for methylamine, and that of triethylamine lowest. It was shown that water uptake and ion exchange capacities increased with increase in the rate of amination while surface area decreased rapidly as proceeding for graft reaction and amination.
Radiation grafting of acrylic acid and 4-vinylpyridine at room temperature has been studied by an impregnation method to improve the hygroscopic properties, the antistatic behavior and the dyeability of polyester fabric. Polyester fabric was impregnated with acrylic acid or aqueous emulsion of acrylic acid-4-vinylpyridine by immersion at 25$^{\circ}$or 7$0^{\circ}C$. The impregnated fabric was irradiated under nitrogen gas with ${\gamma}$-rays from Co-60. When acrylic acid grafted polyester fabric was treated with sodium carbonate, calcium acetate and potassium persulfate, tne rate of water absorption was increased and most parts of polyacrylic acid formed were extracted off from the fabric with 0.1% solution of sodium hydroxide at 10$0^{\circ}C$. In the case of the impregnation of a mixture of acrylic acid and 4-vinylpyridine the petcent of grafting has been shown to be proportional to the ratio of 4-VP/AA and radiation dost. Estimating by contact angle measurements of water on the various polymer surfaces, the antistatic behavior was decreased with the increase of grafting percent. The investigation of electron micrograph disclosed the existence of certain type of discontinuities in the acrylic acid grafted polyester fiber which was treated with various salts.
Journal of the Korean Crystal Growth and Crystal Technology
/
v.22
no.1
/
pp.36-41
/
2012
We have been performed on $Co^{60}$${\gamma}$-ray irradiation of South Sea cultured pearls, with the absorbed dose of 0.1~100 kGy at room temperature. In addition, it was investigated electron paramagnetic resonance (EPR) and amino acid analysis (AAA) for detection of Gamma irradiated South Sea cultured pearls. It was observed that the irradiated South Sea cultured pearls revealed additional free radical peak such as $CO_2^-$, at a g-factor of $2.001{\pm}0.002$ in EPR spectra. From the amino acid analysis (AAA), it was shown that some of amino acid in the protein of the nacre destroyed after ${\gamma}$-ray; glutamic acid residue by 11.43 %, alanine by 3.11 %, and histidine by 43.75 %. It was useful to detect the irradiated South Sea cultured pearls by EPR measurement in our study.
This experiment was carried out to obtain basic informations on the development in sterile-male technique of rice stem borer. The species considered is Chile suppressalis Walker. Different developmental stages of the insect namely; larval, pupae and adult were irradiated with $Co^{60}$ gamma ray. The results obtained were as follows: 1) A 1:1 sex ratio in the pupal stage was observed. 2) In the pupal stage sub-lethal dosages$(LD_{50})$ were 26 KR and 26.7 KR for female and male, respectively. 3) The total number of egg masses per female increased with the increasing gamma ray dosages and average number of eggs produced per female decreased in the cross between normal female and irradiated male. 4) The sterile dosage $(SD_{90})$ of the gamma ray irradiation showed 23 KR in the male. 5) The pupal stage is most convenient developmental stage for irradiation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.