• Title/Summary/Keyword: 선계산

Search Result 2,316, Processing Time 0.039 seconds

Geo-surface Environmental Changes and Reclaimed Amount Prediction Using Remote Sensing and Geographic Information System in the Siwha Area (원격탐사와 지리정보시스템을 이용한 시화지구 일대의 지표환경변화와 토공량 예측연구)

  • Yang, So-Yeon;Song, Moo-Young;Hwang, Jeong
    • The Journal of Engineering Geology
    • /
    • v.9 no.2
    • /
    • pp.161-176
    • /
    • 1999
  • The objectives of this study are to analyze the changes of geo-surface topography in the Siwha embankment and the Ahsan city area by the image processing of Landsat Thematic Mapper data, and to estimate the reclaimed amount of the exposed tidal flat in the Siwha area using the GIS. False color composite, Tasseled cap, NVDI(normalized difference vegetation index), and supervised classification techniques were used to analyze the distribution of sediments and the aspect of topographical variations caused by artificial human actions. The total amount of the exposed tidal flat was estimated on the basis of the database snch as aerial photography, hydrographic chart, geological map, and scheme drawing in the Siwha area. The possible excavation regions for a seawall were predicted analyzing the supervised classification image of Landsat TM data. Tasseled cap images were used to observe the distribution of sediments. The difference of the NDVI images between spring and summer seasons indicates that deciduous and coniferous forests were distributed over the whole areas. The total fill-volume of the exposed Siwha tidal flat and the fill-volume of the construction planning seawall were calculated as $581,485,354\textrm{m}^3{\;}and{\;}3,387,360\textrm{m}^3$, respectively, from the digital terrain analysis. Daebu Island, Sunkam Island, and the part of Songsan-myeon were chosen as the cut area to make the seawall, and their cut-volumes were estimated as $5,229,576\textrm{m}^3,{\;}79,227,072\textrm{m}^3,{\;}and{\;}47,026,008\textrm{m}^3$, respectively. Therefore, the cut-volume of Daebu Island alone among three areas was sufficient to make the seawall.

  • PDF

QUANTITATIVE COMPARISON OF PERMEABILITY IN THE ADHESIVE INTERFACE OF FOUR ADHESIVE SYSTEMS (열순환 후 상아질 접착 계면의 수분 투과성 변화에 대한 정량적 분석)

  • Chang, Ju-Hea;Yi, Kee-Wook;Kim, Hae-Young;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • The purpose of this study was to perform quantitative comparisons of water permeable zones in both the adhesive and the hybrid layer before and after thermo cycling in order to assess the integrity of the bonding interface. Twenty eight flat dentin surfaces were bonded with a light-cured composite resin using one of four commercial adhesives [OptiBond FL (OP), AdheSE (AD), Clearfil SE Bond (CL). and Xeno III (XE)]. These were sectioned into halves and subsequently cut to yield 2-mm thick specimens; one specimen for control and the other subjected to thermocycling for 10,000 cycles. After specimens were immersed in ammoniacal silver nitrate for 24 h and exposed to a photo developing solution for 8 h, the bonded interface was analyzed by scanning electron microscopy (SEM) and wavelength dispersive spectrometry (WDS) at five locations per specimen. Immediately after bonding. the adhesive layer of OP showed the lowest silver uptake, followed by CL, AD. and XE in ascending order (p < 0.0001); the hybrid layer of CL had the lowest silver content among the groups (p = 0.0039). After thermocycling, none of the adhesives manifested a significant increase of silver in either the adhesive or the hybrid layer. SEM demonstrated the characteristic silver penetrated patterns within the interface. It was observed that integrity of bonding was well maintained in OP and CL throughout the thermocycling process. Adhesive-tooth interfaces are vulnerable to hydrolytic degradation and its permeability varies in different adhesive systems, which may be clinically related to the restoration longevity.

The Comparison of Efficacy of Glutathione S-transeferase Placental Form Positive and Iron-Resistant Lesions in the Detection of Hepatocarcinogens (간발암성 물질 검색에 있어서 Glutathione S-transeferase Placental Form 양성 병소와 철 저항 병소의 유효성 비교 연구)

  • 강경선;김형진;이영순
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • Fischer 344 rats aged six weeks were diYided into four groups and group 1, 2, and 3 of rats were given an intraperitoneal injection of diethylnitrosamine at 200 mg/kg body weight and group 4 was given saline alone. Two weeks after beginning of the experiment, group 1 and 2 of rats were begun to feed on diets containing 0.02% 2-acetylaminofluorene as a promoter for four weeks. Three weeks after beginning of the experiment, all groups were performed partial hepatectomy. During the last two weeks, group 1 and 3 of rats were received subcutaneously 3 consecutive weekly doses of iron dextran at 0.125 ml/100 g body weight. Subcutaneous injection of iron dextran resulted in hepatic siderosis in group 1 and 3 of rats. Pre neoplastic nodules were identified histopathologically by two markers, resistance to exogenous iron accumulation and glutathione S-transeferase placental form (GST-P) activity, while early carcinogen induced foci were hardly resistant to iron accumulation and though a few lesions were identified, it could hardly be distincted from normal hepatocytes of surroundings. However, GST-P positive nodules as well as foci were clearly distincted from normal hepatic cells of surroundings. In the quantitative analysis of carcinogen-induced nodules and foci, more lesions were detected by immunohistochemical method for GST-P than by prussian blue staining for resistant to iron accumulation. It is concluded that immunohistochemical marker for GST-P is more sensitive and reliable than iron-resistance marker, and that iron-resistance is not useful marker for early detection of carcinogen-induced hepatic lesions.

  • PDF

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Comparison of Size Criteria in Mediastinal Lymph Node Involvement of Adenocarcinoma of Lungs (폐 선암의 종격동 림프절 전이에 있어서 림프절 크기 기준의 비교)

  • Gu, Ki-Seon;Kuk, Hiang;Koh, Hyeck-Jae;Yang, Sei-Hun;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.542-547
    • /
    • 1999
  • Background: Decision in mediastinal lymph node involvement of lung cancer by CT scan is very important and valuable for the treatment planning and prognosis prediction. In general, long diameter of mediastinal lymph node more than 15mm is used as criterion of lung cancer involvement. Adenocarci-noma has a tendency of early distant metastasis and micrometastasis, so adenocarcinoma may involve lymph node earlier and cannot be detected before lymph nodes are enlarged enough. The authors tried to determine the difference between two size criteria(15mm, 10mm) in adenocarcinoma for the detection of cancer involvement. Methods: Numbers of sample are 60 cases(male 46, female 14, median age: 61.5 years). According to pathology, squamous cancer 41, large cell cancer 2, adenocarcinoma 17. According to TNM stage, I 23, III 24, IIIA 13. Results : Mean long diameter of lymph node involvement is 16.0($\pm8.0$) mm in non-adenocarcinoma group, and that of adenocarcinoma group is 12.0($\pm3.2$) mm(p<0.05). If long diameter of lymph node larger than 15mm as involvement criterion is applied, sensitivity, specificity, positive predictive index, negative predictive index, accuracy of nonadenocarcinoma group are 54%, 100%, 100%, 83%, 86%, and those of adenocarcinoma group are 43%, 90%, 75%, 69%, 71%. If long diameter of lymph node larger than 10mm as involvement criterion is applied, sensitivity, specificity, positive predictive index. negative predictive index. accuracy of nonadenocarcinoma group are 65%, 77%, 61%, 92%, 79%, and those of adenocarcinoma group are 100%, 80%, 78%, 100%, 88%. Conclusion: Long diameter of lymph node larger than 10mm is more valuable criterion as lymph node involvement in adenocarcinoma of lungs.

  • PDF

Effect of Package Size and Pasteurization Temperature on the Quality of Sous Vide Processed Spinach (Sous Vide 가공 시금치의 품질에 미치는 포장단위 및 살균온도의 영향)

  • 장재덕;김기태;이동선
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.195-200
    • /
    • 2004
  • Microbial lethal value and nutrient retention of sous vide processed spinach were evaluated with mathematical model prediction and experimental trial for different package sizes and pasteurization temperatures. The package size covers 500 g, 1 kg and 2 kg, while the pasteurization temperature includes 80, 90 and 97$^{\circ}C$. The basic process scheme consists of filling blanched spinach into barrier plastic film pouch, sealing under vacuum, pasteurization in hot water with over pressure and final cooling to 3$^{\circ}C$. Pasteurization condition was designed based on attainment of 6 decimal inactivation of Listeria monocytogenes at geometric center of the pouch package by heating cycle, which was determined by general method. Heat penetration property of the package and thermal destruction kinetics were combined to estimate the retention of ascorbic acid and chlorophyll. Smaller packages with shorter pasteurization time gave better nutrient retention, physical and chemical qualities. Larger package size was estimated and confirmed experimentally to give higher pasteurization value at center, lower ascorbic acid and chlorophyll contents caused by longer heat process time. Lower pasteurization temperature with longer process time was predicted to give lower pasteurization value at center and lower ascorbic acid, while chlorophyll content was affected little by the temperature. Experimental trial showed better retention of ascorbic acid and chlorophyll for smaller package and higher pasteurization temperature with shorter heating time. The beneficial effect of smaller package and higher pasteurization temperature was also observed in texture, color retention and drip production.

Three Crystal Structures of Dehydrated Partially $Co^{2+}-Exchanged$ Zeolite A Treated with Potassium Vapor (부분적으로 코발트 이온으로 치환한 제올라이트 A를 진공 탈수한 후 칼륨 증기로 반응시킨 3개의 결정구조)

  • Jeong Mi Suk;Jang Se Bok
    • Korean Journal of Crystallography
    • /
    • v.15 no.2
    • /
    • pp.59-68
    • /
    • 2004
  • Three crystal structures of dehydrated partially $Co^{2+}-exchanged$ zeolite A treated with 0.6 Torr of K at $300^{\circ}C$ (for 12 hrs, 6 hrs, and 2 hrs) vapor have been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at 21(1)$^{\circ}C(a=12.181(1)\;{\AA},\;a=12.184(1)\;{\AA},\;and\;a=12.215(1)\;{\AA})\;respectively)$. Their structures were refined to the final error indices, R(weight) of 0.090 with 10 reflections, 0.091 with 82 reflections, and 0.090 with 80 reflections, respectively, for which $1>\sigma(I)$. In each structure, all four $Co^{2+}$ and four $Na^+$ ions to be reduced by K atoms. The cobalt and sodium atoms produced are no longer found in the zeolite. K species are found at five different crystallographic sites: three $K^+$ ions lie at the planes of 8-rings, filling that position, ca. 11.5 K^+$ ions lie on threefold axes, ca. 4.0 in the large cavity and ca. 4.0 in the sodalite cavity, and ca. 0.5 $K^+$ ion is found near a 4-ring. ca. three $K^0$ atoms are found deep into the large cavity on threefold axes. In these structures, crystallographic results show that cationic tetrahedral $K_4$ (and/or triangular $K_3$) clusters have formed in the sodalites of zeolite A. The $K_4$ and/or $K_3$ clusters coordinate trigonally to three oxygens of a six-oxygen ring. The partially reduced ions of these clusters interact primarily with oxygen atoms of the zeolite structure rather than with each other. ca. 14.5K species are found per unit cell, more than the twelve $K^+$ ions needed to balance the anionic charge of zeolite framework, indicating that sorption of $K^0$ has occurred. The three $K^0$ atoms in the large cavity are closely associated with three out of four $K^+$ ions in the large cavity to form $K_7^{4+}$ clusters. The $K_7^{4+}$ cluster not interacts primarily with framework oxygens.

Analysis of Lymphocyte Subsets in Peripheral Blood after Radiotherapy (악성 종양 환자에서 방사선 치료 전, 후의 림프구 아형 분석)

  • Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyun-Sik;Hur, Won-Joo;Kim, Jung-Man
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.229-236
    • /
    • 1996
  • Purpose : To evaluate the changes of differential counts and lymphocyte subsets in cancer patients' leukocyte before and after radiotherapy. Materials and Methods : From Dec. 1994 to Mar 1995, the changes of leukocyte and its subsets in 16 patients who received radiotherapy in the Dept. of Radiation Oncology of Dong-A University Hospital were investigated. Radiation was delivered from 2700 cGy to 6660 cGy with median dose of 5400 cGy. The results of pre- and Post-radiotherapy were analyzed by paired T-test. The results of patients Who received < 50 Gy and $\geq$ 50 Gy were analyzed by Wilcoxon test. Results : Before and after radiotherapy, there was not any significant differences in the counts of leukocyte, granulocyte and monocyte. A remarkable decrease was noted in lymphocyte counts after radiotherapy(p=0.015). T cells, B cells and natural killer cells were also decreased in number after radiotherapy but it was not significant statistically. 1 helper cells and T suppressor cells were also decreased in number(p>0.05). The ratio of T helper/suppressor cell was decreased from 1.52 to 1, 11 and it was significant statistically(p=0.016). The portion of T suppressor cell among all T cells was increased after radiotherapy (p=0.0195). No significant difference was observed in the analysis of leukocyte and its subsets between patients who received < 50 Gy and $\geq$ 50 Gy, Conclusion : Radiotherapy caused remarkable decrease in lymphocyte count and its subsets. Among all lymphocyte subsets, T helper cell might be the most vulnerable to radiation, considering decreased ratio of T helper/suppressor cell count after radiotherapy.

  • PDF

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.