• Title/Summary/Keyword: 석면 농도

Search Result 42, Processing Time 0.037 seconds

The Effect of Pleural Thickening on the Impairment of Pulmonary Function in Asbestos Exposed Workers (석면취급 근로자에서 늑막비후가 폐기능에 미치는 영향)

  • Kim, Jee-Won;Ahn, Hyeong-Sook;Kim, Kyung-Ah;Lim, Young;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.923-933
    • /
    • 1995
  • Background: Pleural abnormality is the the most common respiratory change caused by asbestos dust inhalation and also develop other asbestos related disease after cessation of asbestos exposure. So we conducted epidemiologic study to investigate if the pleural abnormality is associated with pulmonary function change and what factors are influenced on pulmonary function impairment. Methods: Two hundred and twenty two asbestos workers from 9 industries using asbestos in Korea were selected to measure the concentration of sectional asbestos fiber. Ouestionnaire, chest X-ray, PFT were also performed. All the data were analyzed by student t-test and chi-square test using SAS. Regressional analysis was performed to evaluate important factors, for example smoking, exposure concentration, period and the existence of pleural thickening, affecting to the change of pulmonary function. Results: 1) All nine industries except two, airborn asbestos fiber concentration was less than an average permissible concentration. PFT was performed on 222 workers and the percentage of male was 88.3%, their mean age was $41{\pm}9$ years old, and the duration of asbestos exposure was $10.6{\pm}7.8$ yrs. 2) The chest X-ray showed normal(89.19%), pulmonary Tb(inactive)(2.7%), pleral thickening (7.66%), suspected reticulonodular shadow(0.9%). 3) The mean values of height, smoking status, concentration of asbestos fiberwere not different between the subjects with pleural thickening and others, but age, cumulative pack-years, the duration of asbestos exposure were higher in subjects with pleural thickening. 4) All the PFT indices were lower in the subjects with pleural thickening than in the subjects without pleural thickening. 5) Simple regression analysis showed there was a significant correlation between $FEF_{75}$ which is sensitive in small airway obstruction and cumulative smoking pack-years, the duration of asbestos exposure and the concentration of asbestos fiber. 6) Multiple regression analysis showed all the pulmonary function indices were decreased as the increase of cumulative smoking pack-years and especially in the indices those are sensitive in small airway obstruction. Pleural thickening was associated with reduction in FVC, $FEV_1$, PEFR and $FEF_{25}$. Conclusion: The more concentration of asbestos fiber and the more duration of asbestos exposure, the greater reduction in $FEF_{50}$, $FEF_{75}$. Therefore PFT was important in the evaluation of early detection for small airway obstruction. Furthermore pleural thickening without asbesto-related parenchymal lung disease is associated with reduction in pulmonary function.

  • PDF

Asbestos Determination of Some Domestic Building-Materials Using X-ray diffraction (국내 건축자재에 함유된 석면의 함량에 대한 X-선회절분석 연구)

  • Hwang, Jin-Yeon;Lee, Hyo-Min;Oh, Ji-Ho;Park, Gi-Nam
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.119-131
    • /
    • 2011
  • The asbestos contents in some representative building materials were analyzed using JIS (Japanese Industrial Standard) X-ray diffraction (XRD) method. The changes in mineral composition during analysis process and problems in JIS method were also examined. XRD analysis of some representative domestic building materials used for roof, wall, ceiling, and floor indicates that slate have the highest asbestos content having 6.87~6.93% of chrysotile. Other building materials analyzed in this study also have 1.35~3.98% of chrysotile contents. The XRD analysis results of asbestos contents in some domestic building materials are presented in this study. This method is very effective for the asbestos content evaluation of building materials according to newly modified asbestos content regulation (Law of Industrial Safety and Health, 2007-26) that limits asbestos content less than 0.1% by Ministry of Employment and Labor. Small amount of tremolite as well as chrysotile were also observed in some samples. With consideration of crystal shape, contents and geological occurrence, it is considered that tremolite is an associated mineral of chrysotile and is not intentionally added. Complemental analyses with optical microscope and SEM/EDS are also necessary because XRD method cannot distinguish asbestiform from non-asbestiform. The XRD method applied in this study is very effective in the asbestos content analysis of building materials, specially building materials showing high asbestos concentration in residues due to the high loss rate with ashing and acid dissolution procedure.

A study on the survey and reduction of indoor asbestos concentration (실내의 석면농도 실태 조사 및 저감에 관한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Jihoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.325-337
    • /
    • 2014
  • The research on the actual condition of indoor asbestos concentration in Korea has not been thoroughly accomplished up to now. In this research the ratio of asbestos-containing buildings and indoor asbestos concentration was studied. This investigation was conducted in 2012 and 2013 and buildings were categorized based on region, building type by use, existing space(ground or basement), and construction year, respectively. Also the indoor asbestos concentration change was monitored to evaluation the efficiencies of two types of asbestos-concentration abatement devices. As a result, the ratio of asbestos-containing buildings in Seoul was largely decreased. The ratio of asbestos-containing buildings was higher in hospitals and schools regionally and in ground buildings than in basement. The average indoor asbestos concentrations were 0.0011, 0.0008 piece/cc in 2012 and 2013 investigation, respectively. Those values were much lower than standards(0.01 piece/cc), therefore the threat of indoor asbestos concentration might be negligible. In asbestos-concentration abatement experiments, the circulation velocity of ventilator were changed 2-6.7 m/sec. With 6.7 m/sec of velocity of ventilator, the concentration of indoor asbestos was fluctuated and maximum value was 2.4 piece/cc. With 4.5 and 2 m/sec of velocities of ventilator, the maximum concentration of indoor asbestos was fluctuated and maximum value was 0.9 piece/cc. This indicated that the concentration of indoor asbestos was decreased partly due to the free drop of asbestos. From these results, the proper velocity of ventilator seems to be between 4.7 and 6.5m/sec under this circumstance and further research is required. These research results may be used to guideline of asbestos management policy.

A study on development of CRM chrysotile in soil (토양 중 백석면 표준물질 개발에 관한 연구)

  • Choi, Yun-Ho;Kwon, Ye-Bin;Lee, Jin-Wook;Kim, Nam-Jun;Jeong, Min-Jong;Hwang, Beom-Goo;Lee, Jae-Hyung;Sun, Yle-Shik;Kim, Bak-Gil
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • Interested in NOA (Naturally Occurring Asbestos), Korea as well as the USA has been making geologic maps of asbestos distributed mines and surrounding areas, restoring mines, evaluating hazard, and so on. The result can be used to improve the reliability of analysts and analysis institutions by judging the amount of asbestos and set up PLM(Polarizing Light Microscope) information by analyzing in soil. The certification value of 2 kinds of CRM(Certified Reference Material) was performed by counting total 400 points with EPA 600-R-93-116 method using by PLM. The following is the result of homogeneity and stability of 2 kinds of manufactured CRM analyzed by ANOVA (Analysis of variance) and Regression Analysis. Based on the analyzation, the results are satisfied with homogeneity and long-term stability. The analyzed certification value of CRM includes the range of minimum and maximum value of point counting result for chrysotile; low concentration-1% (range, 0.25~3.00), high concentration-4% (range, 2.25~5.50).

A Study on Worker Exposure Level and Variation to Asbestos in some Asbestos Industries (일부 석면취급사업장의 석면폭로 농도 및 작업환경관리 기준에 관한 연구)

  • Oh, Se Min;Shin, Yong Chul;Park, Doo Yong;Park, Dong Uk;Chung, Kyou Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.100-109
    • /
    • 1993
  • This study was performed to evaluate the asbestos exposure levels and variations in textile, brake lining manufacturing and slate manufacturing industries. For this study, fifteen plants of brake lining manufacturing industry, 7 plants of textile industry, and 2 plants of slate manufacturing industry were selected and surveyed. Geometric means (GMs) of airborne asbestos concentrations in textile, brake lining manufacturing, and slate manufacturing industries were 1.42 f/cc(0.07-6.1O f/cc), 0.19 f/cc(<0.01-2.67 f/cc) and 0.08 f/cc(0.02-0.67 f/cc), respectively. In textile industry overall GMs of airborne asbestos concentrations in plants with less than 50 workers and in plants with more than 50 workers were 1.60 f/cc and 0.3 f/cc, respectively. Therefore, the size of plant showed some difference in the airborne asbestos concentrations. Three out of 7(42.9%) exceed the Korean standard, 2 f/cc, and every plant exceed the USA standard, 0.2 f/cc of the OSHA-Permissible Exposure Level(OSHA-PEL). Especially, one plant showed the highest average concentration of 2.87 f/cc. In brake lining manufacturing industry, the plants with less than 50 workers showed 0.22 f/cc. The plants with more than 50 workers showed 0.18 f/cc. All plants showed the exposure level below the Korean standard. Five of 15 (33.3%) were above the OSHA-PEL. One plant showed the highest average concentraton of 0.84 f/cc. In slate manufacturing industry, the average exposure level was 0.08 f/cc, and all of the plants were below the Korean standard and the OSHA-PEL.

  • PDF