• Title/Summary/Keyword: 서보제어장치

Search Result 109, Processing Time 0.03 seconds

A Study on improvement of communication error between controllers for K56 ammunition transport vehicle (K56 탄약운반장갑차용 제어기 간 통신 오류 개선에 관한 연구)

  • Park, Joo-Young;Kim, Seong-Hoon;Noh, Sang-Wan;Park, Young-Min;Kim, Kyung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.781-788
    • /
    • 2021
  • This paper is the study of a design to eliminate the communication error that occurs between the main controller and the servo controller of the K56 ammunition-carrying armored vehicle. The K56 assists in the operation of the K-55A1 self-propelled gun by automating the supply and loading of ammunition. The CAN communication board of the ammunition carrier is a key-function product mounted inside the main controller and installed for communication with the servo controller. It was confirmed that an undefined error would occur intermittently in the existing CAN communication board, interrupting the operation of the ammunition supply system during the loading process. In this paper, in order to solve the problem, the cause of the failure is identified through analysis and a functional test of the communication signal between the main controller and the servo controller. The error was resolved by redesigning and improving the Read/Write algorithm. Finally, the proposed cause analysis and design effectiveness were verified through the CAN communication board single item test and a system equipment application test. It is expected that this study will serve as a reference for improving defense capabilities through improving the reliability of CAN communication boards and by improving the reliability of the overall electronic equipment using DPRAM.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

Fault Diagnosis for High Pressure Turbine Valve using Fuzzy Logic (퍼지 논리를 이용한 원자력 발전소 고압터빈 밸브 고장진단)

  • Kim Yeon-Tae;Jeong Byeong-Uk;Baek Gyeong-Dong;Kim Seong-Sin
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.79-82
    • /
    • 2006
  • 본 논문은 원자력 발전소의 주요 제어계통 중에서 터빈 조속기 제어계통에 관련한 성능평가를 목적으로 한다. 터빈 조속기 계통은 고압의 유압계통으로 구성되어 있어 구동설비가 복잡하다. 복잡한 기계설비는 운전 중 많은 오동작에 의한 고장을 일으키고, 유지보수에 어려움이 있다. 이러한 복잡한 기계설비에 있어 운전원에 의한 기계성능 평가는 불리한 점이 많다. 예를 들어 서로 다른 시간에서 일어나는 같은 상황에 대해 다른 판단을 내릴 수 있다는 점이다. 터빈 조속기 계통의 기계설비에 있어서 터빈 밸브 유압공급 및 구동장치는 각 터빈벨브 자체에 부착되어 있어 터빈벨브를 동작시킨다. 터빈벨브들은 구동기 유압 서보실린더(Actuator Hydraulic Servo Cylinder)에 의해 열리고 압축된 스프링에 의해 닫힌다. 이러한 시스템을 진단하기 위해서 본 논문에서는 밸브의 내부 압력의 특징정보를 입력으로 하는 퍼지이론을 적용하여 터빈 밸브 구동설비의 성능을 판단하고자 한다. 퍼지이론에 적용하기위해 터빈 조속기 제어계통의 고압 터빈 조절 벨브와 고압 터빈 정지 밸브의 압력변화 데이터를 이용한다. 퍼지이론의 적용과정에서 퍼지 Rule은 실제 운전원이 압력변화 데이터에 대한 판단기준을 근거로 하여 정하기로 한다. 그리고 퍼지이론에 적용한 결과를 분석하고 실제 터빈 조속기 계통의 전문가가 판단 결과와 비교하였다.

  • PDF

A PID Genetic Controller Design Using Reference Model (기준모델을 이용한 PID 유전 제어기 설계)

  • Park, K.H.;Nam, M.H.;Hwang, Y.W.;Chun, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.894-896
    • /
    • 1999
  • PID 제어는 50년의 역사를 갖기 때문에 현장의 사용자는 이 제어방식에 익숙해져 있으며, 제어장치의 구성이 간단하며 제어기의 최적동조가 가능하므로 많은 분야에서 사용되고 있다[1]. 그러나 PID 제어기에 의해서 얻은 결과에 대하여 만족하기 위해서는 많은 시행착오를 겪어야 한다. 또한 만족하는 결과를 얻었다고 할지라도 외란, 플랜트의 동특성이 바뀌는 경우 시스템을 추종하지 못하기 때문에 파라미터를 재조정하여야 한다. 유전 알고리즘은 자연세계의 진화 현상에 기초한 계산모델로서 John Holland에 의해서 1975년에 개발된 전역적인 최적화 알고리즘이며[1][2], 비선형 고차원, 불연속, 다중모드, 노이즈 함수 등에 대하여 강건함을 보여주고, 복잡한 탐색 공간에서 최적 값을 스스로 발견하는 학습 능력을 갖는다. 이 방법은 재생산, 교배, 돌연변이를 통하여 최적해를 찾은 방법으로 1989년에 D. E. Goldgerg에 의해서 체계적으로 정리된 후 여러 분야에서 응용되고 있다[3][4]. 그러나 유전 알고리즘은 목적함수만을 이용하여 해집단을 탐색하기 때문에 숙련운전자가 원하는 제어 특성 명세인 상승시간, 정착시간, 초과량(oveshoot) 둥을 구체적으로 명시하여 제어에 반영할 수 없다. 또한, 유전 알고리즘은 입력 값이 크게 바뀔 경우 다른 시스템으로 인식하여 새로운 탐색을 수행하는 단점을 가지고 있다. 본 논문은 첫째, 기준모델을 도입하여 플랜트의 성능을 기준모델로 표현하여 플랜트가 요구하는 성능지표를 정량적으로 규정하는 것이 가능하였다. 또한, 이것은 미지 플랜트 동특성을 식별하기 위한 신호로 사용되어, 플랜트의 정보를 얻는데 이용되었다. 즉, 기준모델과 플랜트 출력사이의 추종 오차 정보가 적응기구인 PID 유전제어기의 입력으로 사용되며, 구형파 입력의 경우에도 기준모델과 플랜트의 출력차는 크게 변하지 않는다. 따라서, 유전 알고리즘의 목적함수에 기준 모델을 제안 적용하여 안정적이고, 세밀한 제어를 수행하였다. 둘째, PID의 간단하면서 확실한 제어가 가능하다는 점과 전역적인 최적값을 찾을 수 있는 유전 알고리즘을 적용하여 고속제어를 요하는 직류 서보 모터(DC Servo Motor) 운전 시 실시간 파라미터 동조에 적용하였다.

  • PDF

A Study Stability Analysis of a PWM Controlled Hydraulic Equipment (PWM 제어되는 유압장치의 안정성 해석)

  • ;Wennmacher, G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

$H_{\infty}$ Position Servo Control of Optical Pick-Ups (광 픽업 장치의 $H_{\infty}$ 위치 서보제어)

  • 임승철;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.119-124
    • /
    • 1996
  • Recently, high speed optical disk drives are increasingly demanded to read or write data fastly enough. To this end, both structure and controller designs of their optical pick-ups should be improved concurrently. In this paper, the pick-up during auto-focusing motion is mathematically modelled retaining all its peculiar features. The model turns out a linear time invariant system suitable for a control design method named H$_{\infty}$ which ensures robust stability in the presence of system uncertainties. Numerical simulation are performed to demonstrate the controller robustness with appropriate performance specifications being satisfied..

  • PDF

A Study on Real Simulator of Running Power Train for Construction Vehicle (건설차량 주행용 동력 전달계의 실시간 시뮬레이터에 관한 연구)

  • 이일영;김진원;윤소남;양경욱
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.90-105
    • /
    • 1996
  • A real tine simulator of running power train for a construction vehicle was developed. The simulator mainly consists of following two parts; (1) running power train part and (2) running load generation part. An optimal servo control algorithm was adopted for designing the multi-variable digital control system of the simulator. By experiments investigating response characteristics under step-wise variation or pre-determined scenario of target vehicle velocity and target load torque, it was verified that the simulator could reproduce physical situations at and actual vehicle with excellent similarity.

  • PDF

Design and Manufacture of Road Simulator for Suspension Durability Test (서스펜션 내구시험용 Road Simulator의 설계 및 제작)

  • 최경락;황성호;전승배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.155-160
    • /
    • 2001
  • The road simulator system can simulate the longitudinal, lateral, and vertical movement changed by road conditions and vehicle dynamic characteristics while driving. This system provides the durability evaluation of vehicle suspensions. The system consists of hydraulic actuators, link mechanism, and servo controller. The hydraulic actuators are specially manufactured using low friction seals to endure high speed movement. The link mechanism is designed in order to minimize the dynamic effect during motion and remove the interference between 3axes actuators. The servo controller is composed of sensors, sensor amplifiers - displacement transducers and load cells, and an industrial PC with DSP board which calculates the control algorithm to control hydraulic actuators. The test results are included to evaluate the performance of this simulator comparing vehicle driving test.

  • PDF

Anti-Saturation Algorithm for a Load Sensing Hydraulic Servo System with Multiple Actuators (다중 작동기를 가진 부하감응 유압서보장치의 포화방지 알고리즘)

  • 이춘호;최필환;김철수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.977-981
    • /
    • 1996
  • A load sensing hydraulic system is widely used to military and commercial mobile applications fur its high running efficiency. Although concept and general control schemes are well known, the poor maneuverability of simultaneous multioperation of actuators still remains to be solved. In this paper, a new control algorithm is proposed to prevent the saturation of the system in such operating conditions, in which the total required flowrate of actuators may exceed the pump supply flowrate. The effectiveness of the proposed algorithm is verified through experiments.

  • PDF

Real Time Tilt Servo Control of The Holographic Data Storage System (홀로그래픽 정보 저장 장치에서의 실시간 틸트 서보 제어)

  • Moon, Jae-Hee;Kim, Sang-Hoon;Yang, Jun-Ho;Yang, Hyun-Seok;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • The purpose of this paper is real time tilt servo control of the holographic data storage system. Holographic data storage device is a next generation data storage device with high storage density, high transfer rate and short access time. This device is very sensitive to a disturbance due to the enormous storage density. As to the recording material changed disc type, the media continuously vibrates as the disc rotates. When disc rotates, deviation, eccentricity and unbalance disturbance are occurred. This disturbances cause disc tilt, finally reference beam does not illuminates to correct incidence angle. Therefore real time tilt servo control is essential. In this paper, the algorithm is proposed to make real time tilt detection in angle multiplexing of the holographic data storage system with an additional servo beam and the experiments are performed.

  • PDF