• 제목/요약/키워드: 생체 임피던스

검색결과 122건 처리시간 0.021초

Measurement of Cardiac Function using Impedance Cardiography (임피던스 심장기록법을 이용한 심장기능의 측정)

  • 김덕원;김정열
    • Journal of Biomedical Engineering Research
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 1988
  • In this paper, principles of impedance tenchinque and relationship between stroke volume and impedance change were theoretically explained. An impedance cardiograph was designed and constructed. Its reproducibility was verified by experiment. Until now, the peak point of dZ/dt waveform, first derivative of impedance change(${\Delta}$Z) , has been detected by software technique requiring considerable time to process. However in this paper its peak point was found using hardware for saving processing time. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution (more than 30%). Hence impedance cardiography was found to be better techique for monitoring stroke volume and myocardial contractility for pre and post operation, and pharmacological studies.

  • PDF

Delection of Distinctive Points in Impedance Cardiogram during Exercise by Cross-Correlation Method (운동중의 임피던스 신호에서 상호상관 관계를 이용한 특성점의 검출)

  • Oh, In-Sik;Song, Chul-Gyu;Kim, Deok-Won;Cha, Il-Whan
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.93-95
    • /
    • 1991
  • As the ensemble averaged dZ/dt signal during exercise is smoothed, it is difficult to find the distinctive marks. The cross correlation function was made use of estmating these marks. LVET was calculated based on the calculated parameters of the characteristic points. For the accuracy validation, LVET calculated by hand, by the ensemble average and the cross correl at ion were compared.

  • PDF

Minimization of Motion Artifact During Exercise in Impedance Cardiography (임피던스 심장기록법에서 운동으로 인한 Motion Artifact의 최소화)

  • Kim, Jung-Chan;Kim, Jeong-Yeol;Kim, Deok-Won;Youn, Dae-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.71-73
    • /
    • 1989
  • The origins of the motion artifact resulting from exercise in impedance cardiography wore explained and the ensemble average technique was applied to reduce the motion artifact enabling the measurement of cardiac output during exercise. Algorithm for ensemble average was developed and applied to the actual impedance signals. It was found that the minimum number of sampling was 20, and sampling frequency was 500Hz. Using the ensemble average technique it was possible to measure cardiac output continuously during the treadmill exercise. Therefore it is hoped that this study may contribute in the area of exercise physiology and sport medicine.

  • PDF

Development of Rheoencephalograph(I) (임피던스 방법을 이용한 뇌혈류량 측정기기의 개발( I ))

  • 김덕원;김정래
    • Journal of Biomedical Engineering Research
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 1989
  • In this study, Rheoencephalography( REG ) was designed and constructed. Using the cons- tructed instrument cerebral blood flow(CBF) of left and right brain, CBF change by posture, and reproducibility were studied. Followings are important results. Relative CBF could be measured noninvasively and continuously. Since reproducibility of the constructed REG was found to be quite high (4%), the accuracy of the instrument itself was proved. REG can be easily applied for testing the effect of drugs for the patients with cerebral vessel diseases since it is quite sensitive to the relative changes of CBF. Various cerebral diseases can be diagnosed by analyzing the REG waveforms. The area of restricted cerebral blood vessels can be located by arranging the electrode configuration. Comparative studies with the standard techinques of measuring CBF are needed to verify the accuracy of REG. Further studies on optimal electrode configuration and various artifacts are also necessary.

  • PDF

Measurements of Cardiac and Respiratory Signals using Impedance Method (임피던스 방법에 의한 심장 및 호흡 신호의 측정)

  • Kim, Hyung-Joong;Shim, Jae-Ok;Jang, Jae-Myeong
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.183-186
    • /
    • 1993
  • We have developed a bioimpedance measurement system for impedance cardiography and pneumography. The system injects 50kHz, $200mA_{p-p}$ curreng into the thorax and measures the voltage changes using body surface electrodes. We used the four-electrode method for tile measurement of cardiac singnals and two-electrode method for respiratory signals. We developed a Microsoft Windows program for the acquisition, display, storage, and processing of impedance signals.

  • PDF

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • 제31권2호
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Design and Performance Analysis of Current Source for 3.0T MREIT System (3.0T MREIT 시스템을 위한 정전류원의 설계 및 성능검증)

  • 김규식;오동인;백상민;오석훈;우응제;이수열;이정한
    • Journal of Biomedical Engineering Research
    • /
    • 제25권3호
    • /
    • pp.165-169
    • /
    • 2004
  • In Magnetic Resonance Electrical Impedance Tomography (MREIT), we inject current through electrodes placed on the surface of a subject and measure the induced magnetic flux density distribution using an MRI scanner. This requires a constant current source whose output pulses are synchronized with MR pulse sequences. In this paper, we present a design and performance analysis of a current source used in a 3.0T MREIT system. The developed current source was tested using a saline phantom. We found that its performance is satisfactory for the current MREIT system. We suggest future improvements for better SNR(signal-to-noise ratio).

Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator (발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서)

  • Ku, Ki-Young;Hong, Yunseog;Lee, Hee-Jo;Yun, Gi-Ho;Yook, Jong-Gwan;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제27권3호
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a vital sign sensor based on impedance variation of resonator is proposed to detect the respiration and heartbeat signals within near-field range as a function of the separation distance between resonator and subject. The sensor consists of an oscillator with a built-in planar type patch resonator, a diplexer for only pass the second harmonic frequency, amplifier, SAW filter, and RF detector. The cardiac activity of a subject such as respiration and heartbeat causes the variation of the oscillation frequency corresponding impedance variation of the resonator within near-field range. The combination of the second harmonic oscillation frequency deviation and the superior skirt frequency of the SAW filter enables the proposed sensor to extend twice detection range. The experimental results reveal that the proposed sensor placed 40 mm away from a subject can reliably detect respiration and heartbeat signals.

The Novel Method of Segmental Bio-Impedance Measurement Based on Multi-Frequency for a Prediction of risk Factors Life-Style Disease of Obesity (비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법)

  • Kim, Eung-Seok;Noh, Yeon-Sik;Seo, Kwang-Seok;Park, Sung-Bin;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • 제31권5호
    • /
    • pp.375-384
    • /
    • 2010
  • The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

A Study on the Validation of Somatotype Drawing as a Instrument of Measuring Obesity Level by Body Component Analysis (생체전기임피던스법을 이용한 체성분 분석에 의한 신체외형도(Somatotype Drawing)의 타당성 연구 - 비만평가도구로서의 타당도 평가 -)

  • Lee Seoung Eun;Jung Young Mi;Chung Kil Soo
    • Journal of Korean Public Health Nursing
    • /
    • 제18권2호
    • /
    • pp.299-311
    • /
    • 2004
  • Purpose: Somatotype drawing developed by Sorensen et al.(1983) has been evaluated as a simple instrument of obesity level without real somatic measuring as height and weight. This study was designed to validate somatotype drawings for obesity assessment by bioelectrical impedance body component analysis. Method: At first questionnaire of somatotype drawing was done. Subjects were measured body component by bioelectrical impedance analysis as weight, BMI(body mass index), WHR(waist-hip ratio), body water, protein mass, mineral mass, body fat mass, skeletal muscle mass, soft lean mass, fat free mass and percent body fat. We evaluated correlations between these data and somatotype drawings and tried to grouping of somatotype drawings with the means of major body component value. Result: The data were collected from 205 college women whose height and weight were $161.2\pm4.8,\;55\pm8.3$. Spearman's correlation coefficients of somatotype drawing were 0.74 with BMI, 0.68 with weight 0.69 with body fat mass, 0.65 with WHR. 0.64 with percent body fat after adiusted age. The grade of somatotype drawings were grouped as 1-2, 3-4, 5-6. 7-9 by BMI, body fat mass, weight, 1, 2-4, 5-6, 7-9 by WHR and 1-2, 3-4, 5-9 by percent body fat(ANOVA and Duncan's method). Conclusion: So quick instrument using somatotype drawings were useful tools for evaluation of obesity level and is applicable to screen degree of body fat in self-administered questionnaire survey.

  • PDF