• Title/Summary/Keyword: 생체적합도

Search Result 827, Processing Time 0.022 seconds

Multi-cell Segmentation of Glioblastoma Combining Marker-based Watershed and Elliptic Fitting Method in Fluorescence Microscope Image (마커 제어 워터셰드와 타원 적합기법을 결합한 다중 교모세포종 분할)

  • Lee, Jiyoung;Jeong, Daeun;Lee, Hyunwoo;Yang, Sejung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.159-166
    • /
    • 2021
  • In order to analyze cell images, accurate segmentation of each cell is indispensable. However, the reality is that accurate cell image segmentation is not easy due to various noises, dense cells, and inconsistent shape of cells. Therefore, in this paper, we propose an algorithm that combines marker-based watershed segmentation and ellipse fitting method for glioblastoma cell segmentation. In the proposed algorithm, in order to solve the over-segmentation problem of the existing watershed method, the marker-based watershed technique is primarily performed through "seeding using local minima". In addition, as a second process, the concave point search using ellipse fitting for final segmentation based on the connection line between the concave points has been performed. To evaluate the performance of the proposed algorithm, we compared three algorithms with other algorithms along with the calculation of segmentation accuracy, and we applied the algorithm to other cell image data to check the generalization and propose a solution.

Automatic Book Turning Tool for The Disabled (장애우를 위한 자동 책 넘김 도구)

  • Park, Cha-Hun;Kim, Min-Uk;Kim, Seon-Ho;Lee, Sang-Mi;Lee, Seung-Min;Jin, Seo-Hyeon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.291-292
    • /
    • 2022
  • 현 사회는 효율성과 편리함을 목적으로 수고를 덜어주는 기계 및 장치, 시스템들을 연구하고 개발하고 있다. 이를 목적으로, 개발되는 시스템에 가장 적합한 대상이 누구인지 파악하는 것도 중요한 요소 중 하나이다. 따라서, 본 프로젝트는 대부분의 사람들에게는 쉬운 행동이지만 신체적 한계로 어려움을 겪는 분들을 대상으로 초점을 맞췄다. 특정한 입력을 인식하여 그 입력에 따라 자동으로 책장을 한 페이지씩 넘겨주는 출력 시스템을 제안한다. 호흡, 손가락 기울기, 버튼 등의 센서에서 감지된 움직임을 통해 최소한의 동작으로 아두이노 기반의 자동화 프로그램 이행을 목표로 하고 있다. 생체 동작 신호 수집을 위한 비접촉 및 웨어러블 센서로 구성되며 수신받은 데이터를 기반으로 각각의 모터에 전송하여 담당하는 작동을 한다. 자동화 및 모션 감지 기술 프로토타입을 제시한다.

  • PDF

Yield Loss Assessment and Economic Thresholds of Squash Powdery Mildew Caused by Sphaerotheca fuliginea (호박 흰가루병의 피해 해석 및 경제적 방제수준 설정)

  • Moon, Youn-Gi;Choi, Jun-Keun;Kang, An-Seok
    • Research in Plant Disease
    • /
    • v.16 no.3
    • /
    • pp.285-289
    • /
    • 2010
  • The experiments were carried out in fields for two years from 2008 to assess yield losses of squash due to powdery mildew caused by Sphaerotheca fuliginea and to determine its economic thresholds. Powdery mildew disease was first observed in late June, about 50 days after field-transplanting, progressed rapidly during late July to early August, and began to reduce from late August. Powdery mildew severity was negatively correlated with squash yields. A positive correlation was observed between fruit weight and % marketable fruits. A simple linear regression model was obtained as Y=-10.399 X + 6607.5 with $R^2$ = 0.9700 when squash yields (Y) was predicted using powdery mildew severity as an independent variable(X). Spray threshold for maximizing squash yields without economic considerations was estimated as 6.5% in terms of leaf lesion area with powdery mildew. Economic threshold and economic spray threshold able to compensate the costs of fungicide sprays were determined as 21.6% and 17.3% in leaf lesion area, respectively.

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF

Corrosion Characteristics of Titanium Alloys for Medical Implant (생체용 Ti 합금의 부식특성)

  • Han, Jun-Hyun;Lee, Kyu Hwan;Shin, Myung Chul
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.192-197
    • /
    • 1996
  • The purpose of this study is to develop new V-free Ti alloys which have good mechanical properties and corrosion resistance. Although pure Ti has an excellent biocompatibility and corrosion resistance in body, it is inferior to Ti alloys in mechanical properties, and Ti-6Al-4V which has good mechanical properties was known to be cytotoxic due to the alloying element V. New Ti based alloys which do not contain the toxic metallic components were developed by the alloy design technique. Their corrosion and mechanical characteristics were compared with pure Ti and Ti-6Al-4V in this study. The results showed that Ti-20Zr-3Nb-3Ta-0.2Pd-1In and Ti-5AI-4Zr-2.5Mo exhibit good mechanical oroperties and an excellent corrosion resistance in 0.9% NaCl solution.

  • PDF

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

Bone Changes in Femoral Bone of Mice Using Calcein Labeling (Mice에서 Calcein 표지를 이용한 골 변화 관찰)

  • Shim, Moon-Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.114-117
    • /
    • 2016
  • In vivo labeling of bone with fluorochromes is a widely used method for assessment of bone formation and remodeling processes. In particular, calcein is used as a marker for identification of bone growth, which is indicated by a green color. Calcein green is a calcium chelator that adheres to regions of mineralizing bone thereby allowing localization of new bone. Bone formation and remodeling in vivo can be assessed by calcium-binding calcein labeling. In this study, changes in the femoral bone of a normal mouse model at both 4 and 8 weeks were evaluated using calcein labeling. Intense deposition of calcium in the bone was observed after application for 8 weeks. A mouse model is suitable for application in in vivo experiments using genetically modified mice, such as knock-out mice, however data regarding femoral cross sectional bone in young mice are limited. The current study confirmed calcein as a useful marker for identification of bone growth, which was indicated by a green color on photomicrographs. This methodological process may provide basic information for interpreting bone formation and regeneration to pharmacologic or genetic manipulation in mice.

로터스 금속의 제조 기술 및 응용

  • Hyeon, Seung-Gyun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.57.1-57.1
    • /
    • 2012
  • 금속을 용해 응고시킬 때 생성되는 소위, 주조 결함이나 소결금속 내의 기공은 재료의 성능이나 강도를 현저하게 낮추는 결함으로서 예전부터 기피되어 왔다. 또한, 재료공정에 있어서도 여하의 기공이나 기포가 없는 치밀한 고강도 및 고기능성 재료를 개발하는 것에 최대한의 주의와 관심을 기울여 왔다. 반면에 자연계의 천연물이나 인공물을 둘러보면 그 대부분이 다공질임을 쉽게 눈치챌 수 있다. 예를 들어 목재, 지엽 등의 생물을 시작해서 콘크리트 등의 인공물, 우리 체내의 뼈도 전형적인 다공질구조로 구성되어 있다. 이러한 구조로부터 재료의 재질제어 이외에 구조제어라는 새로운 어프로치를 고려할 수 있고, 최근 들어, 금속재료에 있어서도 이러한 다공질 구조에 관한 연구가 활성화되어 충격흡수재, 생체재료, 베어링재료 등의 다양한 응용이 전개되고 있다. 원주상의 방향성 기공을 갖는 로터스 금속의 제조 원리는 용융금속의 높은 가스용해도와 고체금속의 낮은 가스고용도의 차이를 이용하여 응고할 때 고용되지 않는 가스원자가 기포를 형성시키는 것이다. 수소용해도는 모든 금속에 있어서 온도상승에 따라 증가하지만 융점에 있어서 용해도의 불연속적 증가를 나타내며 응고할 때 고액계면에서 다량의 가스를 방출하고 기공 생성을 야기한다. 특히, 고 액상에 있어서 수소용해도 차가 큰 마그네슘, 니켈, 철, 동 등은 기포를 생성하기 쉽다. 또한 기공의 배열구조를 제어하기 위해 일방향응고법를 이용하여 기공에 방향성을 부여한다. 외관상 기공구조가 연근뿌리를 닮은 것으로 부터 로터스 금속이라는 명칭이 널리 알려져 있다. 이와 같은 제조방법에 의해 로터스 금속은 기공 방향, 기공크기, 기공률을 자유롭게 제어할 수 있고 우수한 기계적 성질이 기존의 발포금속, 소결금속과 전혀 다른 특성을 가지고 있다. 이러한 기공구조는 용해온도, 응고속도, 분위기 가스압, 불활성가스와의 혼합체적비 등의 제어를 통해서 조절할 수 있다. 이와 같이 제조한 방향성 다공질금속은 BT (인플란트, 생체적합성, 저탄성, 경량), ST (초음속기엔진부품, 경량), IT (고성능수냉모듈), ET(고온촉매, 필터)의 분야로의 응용을 기대한다.

  • PDF

자기조립박막 증착법을 이용한 영구적인 친수성 표면의 플루이딕스칩 제작에 관한 연구

  • Kim, Dong-Jin;Lee, Mun-Gwon;Lee, Jeong-Hwan;Im, Hyeon-U;Park, Jin-Gu;Sin, Sang-Taek;Kim, Jeong-Ho;Jo, Byeong-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.49.2-49.2
    • /
    • 2009
  • 최근, 플루이딕스칩 제작에 있어서 가격이 저렴하며 구조물 형성이 쉽다는 장점으로 인하여 유리 기판을 플라스틱 기판으로 대체하려는 연구가 많이 진행하고 있다. 하지만 플라스틱 기판은 유리 기판에 비하여 많은 장점을 갖고 있음에도 불구하고, 기판 표면이 소수성이기 때문에 유체의 흐름을 저하시키는 문제점이 있다. 기존의 플라스틱 기판을 친수성으로 개질하는 방법으로는 화학적처리, 자외선 조사, 산소플라즈마 처리 등의 방법이 있었으나, 화학적처리 방법은 공정의 민감성과 폐기물로 인한 양산적용의 한계가 있고, 자외선 조사법 및 산소 플라즈마 처리는 친수성이 영구적이지 않다는 결정적인 문제점이 있다. 이는 플라스틱 플루이딕스칩의 신뢰도를 크게 저해하여 상용화에 큰 문제점으로 작용한다. 이러한 문제점을 극복하기 위한 새로운 방법의 친수성 표면처리가 요구되어 지고 있다. 본 연구에서는, 기존 플라스틱 기판의 친수성 표면처리 방법들의 문제점들을 개선하고자 플라스틱 기판의 변형을 야기하지 않는 저온 PE-CVD 방식을 이용하여 균질한 두께의 $SiO_2$박막을 형성 하였으며, 형성된 박막을 liquid self-assembled monolayer(L-SAM)방식을 이용하여 아민 표면으로 개질하였다. 이를 통해, 플라스틱 채널 상에서 유체의 원활한 흐름, 형성된 아민 표면에 단백질 및 DNA와 같은 생체 물질 고정화의 용이성 및 영구적 표면개질의 특성을 얻을 수 있었다. 이뿐만 아니라, 플라스틱 기판 외에도 재료에 관계없이 모든 물질의 표면을 생체 안정성이 뛰어난 친수성 표면으로 개질 할 수 있으며, 알데히드 및 카르복시산 등의 다양한 작용기로 변형이 쉽다는 장점이 있다. 개질된 친수성 표면의 평가를 위하여 시간에 따른 접 촉각 및 형광 스캐너(Fluorescence Scanner)를 이용하여 영구적인 친수성 특성 및 생체물질 적합성을 파악하였다. 또한, L-SAM 조건에 따른 아민의 형성정도를 측정하기 위하여 XPS(X-ray Photoelectron Spectroscopy) 분석을 실시 하였다. 최적화된 표면처리를 실제 플라스틱 플루이딕스칩에 적용하여, 유체의 흐름을 관찰 하였다.

  • PDF

Intra-Body Communication System for Bio Sensors (생체센서를 위한 인체통신시스템)

  • Jung, Jae-Wook;Kang, Jung-Mo;Kim, Myung-Sik;Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1749-1754
    • /
    • 2007
  • In this paper, we propose a new Intra-body communication system for bio-sensor which is one of applications in PAN(Personal Area Network) using body channel. The communication systems for bio-sensor network usually transmits a lot of data acquired in sensor to the receiver in wrist or waist. So we deign the intra-body modem with high data rate, low power, and small size which are achieved by baseband communication techniques. It is noted that the baseband transmission does not requires any analog IF and RF frontends, and can be operated in lower frequency than bandpass transmission. The proposed modem operates at 10MHz band according to the characteristics of intra-body channel, and shows the capability of 5Mbps data rate at distance of 20cm, with $BER=10^{-5}$. In addition, we implement the modem within $2{\times}2cm$ area.