• Title/Summary/Keyword: 생체역학적 설계

Search Result 31, Processing Time 0.024 seconds

Design of the Interspinous Process Fixator Using Biomechanical Analysis for the Treament of Degenerative Lumbar Spinal Stenosis (퇴행성 요추부 척추관 협착증 치료를 위한 극돌기간 고정기구의 설계 및 생체역학적 분석)

  • Heo S.;Son K.;Lee S.J.;Moon B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1963-1966
    • /
    • 2005
  • Degenerative lumbar spinal stenosis(DLSS) is a disease inducing low back pain, leg pain, convulsion, numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degenerative of neighbor region after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design of the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified fixators using the finite element analysis(FEA). Displacement, stiffness and Von-Mises stress were found to have similar values to those obtained from the mechanical test and the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator.

  • PDF

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.

Biomechanical Effect of Forearm Flexor Muscles depending on Handle Sizes (수공구 손잡이 형태에 따른 생체역학적 영향도 분석)

  • Park, Shi-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.41-48
    • /
    • 2012
  • 수공구 사용시 과도한 힘은 작업성 근골격계 질환을 일으킬 수 있는 주요 원인중 하나이다. 이와 관련하여, 수공구 파지시 인체 내부에 부과되는 근력과 외적으로 작용된 힘 간의 비율을 이해하는 것이 중요하며, 이는 근육에 부과되는 과도한 힘을 최소화 시키고, 작업에 필요한 힘의 효율성을 극대화 시키는데 필수적이라 할 수 있다. 이러한 비율과 관련하여 많은 연구가 되어 왔으나, 대부분 수리적 인체역학적 모델과 같은 간접적 추정 방법에 의거하고 있는 실정이다. 이러한 인체역학적 모델을 검증하고 개선하기 위하여 해부용 팔 (cadaver)을 활용한 직접적인 근력과 악력 측정이 필수적이다. 본 연구에서는 이러한 해부용 팔을 이용하여 상지 굴근(hand flexor)을 자동으로 제어하고 근력과 함께 악력을 측정할 수 있는 Hand Motion Simulator를 개발하고, 이를 통하여 다양한 사이즈의 손잡이 파지시 요구되는 근력과 외적으로 적용된 악력을 비교함으로써 수공구 손잡이 사이즈에 따른 근력의 효율성에 대하여 측정을 해 보았다. 또한, 적용된 굴근 (FDP & FDS) 간의 힘 비율에 따른 파지법의 차이를 조사해 보았다. 내부에 주어진 근력은 외부로 작용된 악력보다 5.3배 높은 부하가 작용하였으며 이러한 수공구 손잡이 파지시 힘의 효율성 역시 FDP 와 FDS 간의 비율이 3:2 였을 때, 그리고 손잡이 크기가 작을수록 높은 결과를 보였다. 반대로 손잡이의 크기가 커질수록 힘의 효율성은 저하되었다. 또한, 손가락 관절 각도의 경우 FDP와 FDS간의 비율에 따라 상이한 자세를 나타내었다. FDP 굴근의 비율이 높을 경우 손가락 끝마디 관절 (DIP) 의 굴곡을 보였으며, FDS 굴근 비율이 높을 경우 손가락 두 번째 관절(PIP)의 굴곡을 보였다. 본 연구를 통한 결과는 추후 상지작업자에 대한 근골격계 질환 예방 기준안 마련 및 수공구 설계를 위한 기초자료로 활용이 가능할 것으로 보인다.

Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring (사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발)

  • Jang, Sunmin;Cho, Sumin;Joung, Yoonsu;Kim, Jaehyoung;Kim, Hyeonsu;Jang, Dayeon;Ra, Yoonsang;Lee, Donghan;La, Moonwoo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.249-254
    • /
    • 2022
  • With the rapid advance of the semiconductor and Information and communication technologies, remote environment monitoring technology, which can detect and analyze surrounding environmental conditions with various types of sensors and wireless communication technologies, is also drawing attention. However, since the conventional remote environmental monitoring systems require external power supplies, it causes time and space limitations on comfortable usage. In this study, we proposed the concept of the self-powered remote environmental monitoring system by supplying the power with the levitation-electromagnetic generator (L-EMG), which is rationally designed to effectively harvest biomechanical energy in consideration of the mechanical characteristics of biomechanical energy. In this regard, the proposed L-EMG is designed to effectively respond to the external vibration with the movable center magnet considering the mechanical characteristics of the biomechanical energy, such as relatively low-frequency and high amplitude of vibration. Hence the L-EMG based on the fragile force equilibrium can generate high-quality electrical energy to supply power. Additionally, the environmental detective sensor and wireless transmission module are composed of the micro control unit (MCU) to minimize the required power for electronic device operation by applying the sleep mode, resulting in the extension of operation time. Finally, in order to maximize user convenience, a mobile phone application was built to enable easy monitoring of the surrounding environment. Thus, the proposed concept not only verifies the possibility of establishing the self-powered remote environmental monitoring system using biomechanical energy but further suggests a design guideline.

Prosthetic rehabilitation by obturator considering the biomechanics in partially edentulous patient after maxillectomy (상악골 절제술을 받은 부분 무치악 환자에서 생역학을 고려해 제작한 구개 폐색장치를 이용한 보철 수복 증례)

  • Lee, Kang-Shin;Park, Ju-Mi;Ahn, Seung-Geun;Seo, Jae-Min;Park, Yeon-Hee;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.281-293
    • /
    • 2021
  • Patients who went through maxillectomy can have severely impaired swallowing, mastication, and pronunciation functions because of palatal defects. Leakage occurs through the nasal cavity while eating, chewing becomes difficult due to the loss of teeth and alveolar ridges, and oral and nasal passages are not separated, leading to hyper-nasal sound, and significantly reducing the quality of life. To prosthetically reconstruct the defect, the weight of the obturator should be reduced as much as possible to minimize dropout because of gravity, and the bulb of the obturator should be properly extended into the defect to get additional retention and stability. In this case of a partially edentulous patient who underwent additional maxillary resection because of tumor recurrence, a metal framework was designed by applying the basic design principles of removable partial dentures. An obturator with improved retention, stability, and support was fabricated through functional impressions. The patient was satisfied with the improved facial expression, mastication, swallowing, and pronunciation, and showed stable occlusion and oral hygiene management during the follow-up period.

Research about the Effect that Taekwondo Shoes have on the Performance and Friction during the Turing and Turning Back Kick (태권도 돌려차기와 몸돌려 후려차기시 태권도화 착용에 따른 기계적 마찰력과 태권도 수행력 연구)

  • Park, Seung-Bum;Lee, Jung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.117-127
    • /
    • 2008
  • The purpose of this study was to investigate the relationship between research of mechanical friction and Taekwondo kick performance. For this a Taekwondo kick performance test, A.F.T.S.(Automated Footwear Testing System) and survey about fitting was used. There was a statistically significant difference between all the Taekwondo shoe types. While performing the roundhouse kick there were statistically significant differences in the peak free moment(p=.01) and peak plantar pressure between type A and B. Comfort testing revealed that there were statistically significant difference between type A and B in the five comfort variables tested but not between type B and Type C. There was statistically significant differences between each of the Taekwondo shoes but there was no relationship between the performance and the results of the survey.

한국 작업자의 요통예방을 위한 작업하중 설계지침

  • 이관석;박희석;서치원
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.97-105
    • /
    • 1995
  • 본 연구의 목적은 드는 작업에 있어서 한국 작업자의 적정하중을 구하여 중량물 안전기준을 정하는 것이다. 본 연구에서는 주어진 작업조건하에서 피실험자가 들어올릴 수 있는 적정하중을 결정하기 위 한 기준으로서 피실험자 자신에 의해서 인지되는 스트레스 정도를 이용하는 심리육체적 방법(Psychophysical method), 주어진 작업조건하에서 요추에 가해지는 압력을 이용하는 생체역학적 방법(Biomechanical method), 주어진 작업조건하에서 피실험자의 에너지 소모량을 이용하는 생리학적 접근법등이 이용되었다. 피실험자는 학생(n=3) 두개의 군으로 나뉘어진다. 실험에 들어가기 전에 피실험자에 대한 인체측정과 근력측정을 수행 하였다. 실험은 수직면에서 드는 빈도(1,2, 와 4회/분)와 드는 높이(0-8cm 와 47-102cm)를 조합한 6가지의 작업을 무작위로 선택하여 심리육체적 방법으로 각 작업에 대한 적정하중을 구하였다. 연구결과로서 피실험 자의 신체자료와 근력의 비교로부터 신체조건은 학생이 우수하였으나, 근력은 작업자가 우수하였다. 본 연구 에서 채택된 들기의 빈도가 변함에 따라 최대허용 하중은 변하였다. 작업자군에 대하여는 빈도가 증가할수록 최대허용 하중은 감소하였으며, 학생군에 대하여는 분당 1회와 분당 4회간의 유의한 차이가 있었다. 들기의 시작-종점의 변화에따른 최대허용 하중은 통계적으로 유의하지 않았다. 위의 두 결과는 들기의 빈도가 들기의 시작-종점보다 민감한 변수임을 가리키며 이는 미국 NIOSH의 결과와 일치한다. 심리육체적 방법을 사용하여 우리나라의 젊고 건강한 남성의 대부분(99%)을 고려하여 산출된 최대허용 하중은 미국 NIOSH 안전기준과 큰 차 이가 없음을 발견하였다. 또한 이 최대허용 하중은 인체역학적방법과 생리학적 방법을 사용하여 검토한 결과, 무리가 없는 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.

  • PDF

Design and manufacture of carrying along style HRV operational bioinstrumentation system that apply AVR MCU(II) (AVR MCU를 적용한 휴대형 HRV 생체 계측시스템의 설계 및 제작(II))

  • Kim, Whi-Young;Park, Doo-Yul
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.4
    • /
    • pp.295-302
    • /
    • 2007
  • Because Mobile computing uses radio transfer communications division carrying along information terminal, internet link computer and information technology of human body effectively, when, where, who, can offer role that is center enemy of available modern technology moving and reconsider new technology to physiological sounding, and reconstruct creatively. Specially, can offer possibility that can intervene in process that motive living body change before military register symptoms are developed of disease on silver society. But, much parameters data processing, standard anger of data of that is vague. same time collection of data can lift difficulty etc.. Therefore, this research excludes time limitation constituent inflecting Mobile computing, and result that analysis experiments because is proper and Mobile nerve mechanical code Tuesday that do with bioelectricity signal method select and embody system by access that become correct analysis, is becomes model of living body signal Mobile analysis device, and person could apply Mobile living body measuring device m-HSS (mobile-Hardware-software system) that measuring is possible by scientific access.

  • PDF

Numerical Analysis of the Blood Flow in the Korean Artificial Heart Using Two Dimensional Model (2차원 모델을 이용한 한국형 인공심장 내 혈액 유동에 대한 수치적 해석)

  • 박명수;심은보;고형종;사종엽;박찬영;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.301-307
    • /
    • 2003
  • In this study, we Presented computational results on the blood flow in the sac of the Korean artificial heart. Two dimensional unsteady flow was assumed and we utilized a finite element commercial code ADINA to simulate the blood flow. Rigid body-solid contact were considered between the actuator and the blood sac and fluid-structure interaction between the blood and the sac. The three geometric models proposed in the design process were simulated to assess the hemodynamic characteristics of the models According to the computational results, a strong flow to the outlet and a stagnated flow region near the inlet were observed during systole. The sac was filled with blood and recirculating flow was generated near the outlet during diastole. Shear stress during systole had its extreme values near the outlet edge whereas the magnitude of shear stress values were relative)v high near the inlet edge and the contacting surface with the actuator.

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.