• Title/Summary/Keyword: 생체모사

Search Result 113, Processing Time 0.023 seconds

Bio-inspired Cell Deformability Monitoring Chips Based on Strain Dependent Digital Lysis Rates (미소유로의 길이에 따른 통과세포의 파괴율을 바탕으로 한 생체모사 세포 변형성 검사칩에 관한 연구)

  • Youn, Se-Chan;Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.844-849
    • /
    • 2008
  • We present a novel cell deformability monitoring chip based on the digitally measured cell lysis rate which is dependent on the areal strain of the cell membrane. This method offers simple cell deformability monitoring by automated high-throughput testing system. We suggest the filter design considering the areal strain imposed on the cell membrane passing through the filter array having gradually increased orifice length. In the experiment using erythrocytes, we characterized the cell deformability in terms of average fracture areal strain which was $0.24{\pm}0.014\;and\;0.21{\pm}0.002$ for normal and chemically treated erythrocytes, respectively. We also verified that the areal strain of 0.15 effectively discriminates the deformability difference of normal and chemically treated erythrocytes, which can be applied to the clinical situation. We compared the lysis rates and their difference for the samples from different donors and found that the present chips can be commonly used without any calibration process. The experimental results demonstrate the simple structure and high performance of the present cell deformability monitoring chips, applicable to simple and cost-effective cell aging process monitoring.

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF

Fuzzy control of a Fed-Batch Fermentation with Substrate Inhibition Kinetics (기질저해가 있는 유가식 발효공정의 퍼지제어)

  • 최정우;오승목;이광순;이원홍
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.3
    • /
    • pp.3-18
    • /
    • 1993
  • 본 논문에서는 박테리아에서 생성되는 생체 계면활성제인 emulsan의 생산을 위한 유가식 배양에서 에칸을 농도의 제어에 퍼지기법을 적용하였다. 기절저해가 있는 유가식 배양에서 emulsan의 생산을 향상시키기 위해 최대 비성장속도를 갖는 최적 기질농도가 유지되도록 기질인 에탄올의 공급 속도가 조절되어 졌다. 생물반응기에서 Acunetobacter calcoaceticus RAG-1 박테리아를 회분식과 유가식으로 배양 실험하여 최적 에탄올 농도를 구하고, kinetic 모델을 제시하였다. 배양실험의 결과와 지식을 바탕으로 퍼지 규칙을 구성하였다. 퍼지 제어기에서 제어 입력변수는 기질농도의 최적치와 운전치의 오차와 오차의 변화로서 구성되고, 제어 출력변수는 기질 공급 속도의 변화량으로 구성되었다. 멤버쉽 함수를 입력변수의 퍼지 집합화 과정을 통하여 구하였고, 최소-최대법과 무게 중심법을 이용하여 출력 제어값을 구하였다. 유가식 배양의 전산모사와 실험 결과에서 퍼지제어 기법은 최적 기질 농도를 정확히 제어하였으며, emulsan 생산은 향상되었다.

  • PDF

Milli-Scale Hexapedal Robot using 4-bar Linkages (4절 링크를 활용한 소형 6족 보행 로봇)

  • Cha, Eun-Yeop;Jung, Gwang-Pil
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.912-916
    • /
    • 2018
  • Crawling robots are advantageous in overcoming obstacles. These robots have characteristics such as light weight and outstanding mobility. In case of large robots, they have difficulties passing narrow gaps or entering the cave. In this paper, we propose a milli-scale hexapedal robot using 4-bar linkages. Two conditions are necessary to enable efficient walking. In short, the trajectory of the foot must be elliptical, and the lowest point of the foot should be the same. These conditions are satisfied with a novel leg design. The robot has a pair of three legs and the legs are coupled to operate simultaneously. Each set of the legs are installed to robot's both sides and the legs satisfy the equal lowest foot point and elliptical trajectory. As a result, this hexapedal robot can crawl with 0.56m/s speed.

Design and Optimization Study of Active Trasfemoral Prosthesis leg (대퇴 절단 환자를 위한 능동대퇴의지구조 설계 및 최적화 연구)

  • Lee, K.H.;Chung, J.H.;Lee, C.-H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.41-46
    • /
    • 2013
  • IIn this paper, active trasfemoral prosthesis leg is designed for the handicapped who lost their legs upon knee. It is important to design proper knee joint to mimic walking motion of hyman. 1 degree-of-freedom active trasfemoral prosthesis leg is designed with knee joint. Operating angle and torque have been calculated using kinematics of three linkages in prosthesis leg. Finite element analysis of major components is performed to evaluate the safety under operating condition and to reduce weights. Minimum volumes of components are obtained by optimization as satisfying safety requirements. The results show that about 35% of weight of components is reduced.

  • PDF

The PIV measurements on the respiratory gas flow in human airway (호흡기 내 주기적 공기유동에 대한 PIV 계측)

  • Kim, Sung-Kyun;Chung, Seong-Kyu
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.93-98
    • /
    • 2005
  • The mean and RMS velocity field of the respiratory gas flow in tile human airway was studied experimentally by particle image velocimetry(PIV). Some researchers investigated the airflow for the mouth breathing case both experimentally and numerically. But it is very rare to investigate the airflow of nose breathing in a whole airway due to its geometric complexity. We established the procedure to create a transparent rectangular box containing a model of the human airway for PIV measurement by combination of the RP and the curing of clear silicone. We extend this to make a whole airway including nasal cavities, larynx, trachea, and 2 generations of bronchi. The CBC algorithm with window offset (64*64 to 32*32) is used for vector searching in PIV analysis. The phase averaged mean and RMS velocity distributions in Sagittal and coronal planes are obtained for 7 phases in a respiratory period. Some physiologic conjectures are obtained. The main stream went through the backside of larynx and trachea in inspiration and the frontal side in expiration. There exist vortical motions in inspiration, but no prominent one in expiration.

  • PDF

Characterization of Frequency Separation in Polymer Membranes Mimicking a Human Auditory System (생체 청각기구를 모사한 폴리머 박막의 주파수 분리 특성 평가)

  • Song, Won-Joon;Bae, Sung-Jae;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.516-521
    • /
    • 2011
  • The basilar membrane, an important functional part of the cochlea, is responsible for spectral separation of vibration signals transmitted from the stapes. In current study, scaled-up polymer membranes designed by mimicking the human basilar membrane were used for investigation of the frequency-separation characteristic. Displacement field formed on each polymer membrane was acquired by Laser Doppler scanning vibrometer and post-processed frequency-wise. The locations of the maximum displacement along the centerline were identified and collected for individual frequency range to produce the frequency-position map of individual polymer membrane. The influences of the membrane thickness and material properties on the variation of the frequency separability were discussed.

The experimental research on periodic airflow in human nasal cavity (비강내 주기유동장의 실험적 해석에 관한 연구)

  • Kim, Sung-Kyun;Son, Yeong-Rak;Sin, Seok-Jae
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1687-1692
    • /
    • 2004
  • Airflow in the nasal cavity of a normal Korean adult is investigated experimentally by tomographic PIV measurement. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiology and pathology aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. All of these researches on nasal airflow are under the condition of constant flow-rate. In this study, nasal cavity flow with the physiological period is investigated by tomographic PIV, for the first time. A pumping system that can produce the periodic flow is created. Thanks to a new method for the model casting by a combination of the rapid prototyping and curing of clear silicone, a transparent rectangular box containing the complex nasal cavity can be made for PIV. The CBC PIV algorithm is used for analysis. Phase-averaged mean and RMS velocity distributions are obtained for inspirational and expiration nasal airflows. The comparison with the constant flow case is appreciated. There exist many flow patterns depending on each phase.

  • PDF

Evaluation of Skin Texture and Wrinkle Using Optical Coherence Tomography (Pilot Study) (피부결 및 주름 평가에 있어 광학단층영상술(Optical Coherence Tomography, OCT) 활용 연구(Pilot Study))

  • Kim, Seunghun;Ahn, Yujin;Sanzhar, Askaruly;Kim, Pilun;Jung, Woonggyu;Lee, Haekwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.3
    • /
    • pp.247-254
    • /
    • 2017
  • Optical Coherence Tomography (OCT) is a non-invasive imaging method that utilizes the optical scattering and interference for visualizing the surface as well as cross-sectional structures of tissue. OCT has been used for diagnosing diseases in early stage in various medical fields, but an application in cosmetics is still at early stage. In this study, OCT was adopted to evaluate skin texture and wrinkle. Results showed similar patterns of evaluation with PRIMOS in the assessment using replica. In addition, OCT produced smaller errors at different angles compared to the PRIMOS in the assessment using 3-dimensional models of wrinkles. The resolution of the image was also high enough to differentiate the images of before and after the application of makeup products. Possible use of OCT in the evaluation of fine wrinkle assessment was studied in this research. Further development of methods is necessary to provide more evidences of the effectiveness.

Fabrication and Medical Applications of Lotus-leaf-like Structured Superhydrophobic Surfaces (연잎 모사 구조로의 초소수성 표면 처리와 의료분야의 적용에 관한 연구)

  • Lim, Jin Ik;Kim, Seung Il;Jung, Youngmee;Kim, Soo Hyun
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.411-419
    • /
    • 2013
  • Various biomaterials have been widely used for biomedical applications, including bio-organs, medical devices, and clinical devices like vessel, blood pumps, artificial kidneys and hearts, even in contact with blood. The issue of blood compatibility has been studied intensively to prevent negative effects such as thrombosis due to the implanted devices. The use of lotus-leaf-like structured surfaces has been extended to an increasing number of applications such as contamination prevention and anticorrosion applications. Various methods such as template, sol-gel transition, layer-by-layer, and other methods, developed for the fabrication of lotus-leaf-like surfaces have been reported for major industrial applications. Recently, the non-wettable character of these surfaces has been shown to be useful for biomedical applications ranging from blood-vessel replacement to antibacterial surface treatment. In this review, we provide a summary of current and future research efforts and opportunities in the development and medical applications of lotus-leaf-like structure surfaces.