• Title/Summary/Keyword: 생체량 측정

Search Result 432, Processing Time 0.031 seconds

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

A study on the real time fetal heart rate monitoring system by high resolution pitch detection algorithm (고해상 피치 검출 알고리듬을 적용한 실시간 태아 심음 감시시스템에 관한 연구)

  • 이응구;이두수
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.175-182
    • /
    • 1995
  • Despite the simplicity of processing, a conventional autocorrelation function (ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal, the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing and studied the real time FHR monitoring system by high resolution pitch detection algorithm.

  • PDF

Evaluation of Exposure Times for Periphyton Biomass Estimate using Artificial Substrata in Headwater Streams (상류하천에서의 인공저층을 이용한 부착조류의 생체량 측정을 위한 노출기간 평가)

  • Kim, Hyun-Woo;Ha, Kyong;Joo, Gea-Jae
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.112-115
    • /
    • 1998
  • During the spring and fall of 1994 and winter of 1995, the exposure time of periphyton biomass on terval. In the streams with low periphyton biomass (chi. a: 2-4 mg/$m^2$) in natural rocks, biomass of arttificial substrata (unglazed tile: $3.7{\times}9.5{\times}2 cm$) exceeded that of the natural rocks after 28 days, while sites with high biomass (chi. a: 20-60 mg/$m^2$) in natural rocks showed slower biomass accumulation after 40 days. Due to the high licht input and temperature in a Partially shaded mountain stream, development of periphyton biomass in spring occurred faster than that of winter. In general, development of periphyton biomass placed on artificial substrata took 4-5 weeks in spring and at least 6 weeks In winter to reach the natural level.

  • PDF

Analysis of Upper Limb Movement Using Bio-Impedance (임피던스를 이용한 상지 운동 분석)

  • Kim, Soo-Chan;Nam, Ki-Chang;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.461-464
    • /
    • 2001
  • 본 연구에서는 생체 임피던스를 이용하여 3채널 상지(upper arm) 운동 분석 시스템을 제작하였다. 각 채널은 상지의 외전(supination)과 내전(pronation), 팔꿈치(elbow)의 폄과 굽힘, 손목(wrist)의 평과 굽힘에 따른 각 관절의 임피던스 변화를 얻을 수 있도록 설계되었다. 상체 임피던스는 전극의 부착위치에 의존하므로 정밀한 감지를 위해 상지 운동에 대한 임피던스의 변화와 각도계(goniometer)의 각도 변화와의 상관관계를 통하여 상관 관계가 높고, 변화량이 가장 크고 다른 관절의 움직임에 따른 영향이 최소인 곳을 찾아 이를 최적의 전극 위치로 정하였다. 그리고, 선정된 최적의 전극 위치에서 임피던스 변화를 얻어 상지 운동을 분석해 보았다. 최적의 전극 위치에서 손목과 팔꿈치의 각도 변화와 임피던스 변화의 상관 계수는 각각 0.94, -0.97로 아주 높은 상관 관계를 보였다. 또한 이전의 다른 연구에서 임피던스 방법으로 구현해 본적이 없는 팔의 회전(rotation)도 분석이 가능하였다. 이 시스템은 피검자의 동작에 거의 제한을 주지 않고, 가벼우며, 장시간 측정이 용이할 뿐만 아니라 시스템 구성이 영상 분석기에 비해서 단순하다는 장점을 가지고 있다. 본 연구에서 제안하는 방법은 재활과 생체역학, 로봇의 원격 제어, 그리고 가상 현실에서의 동작 구현 등에 활용 할 수 있을 것으로 사료된다.

  • PDF

The efficacy of biofeedback in reducing cybersickness in virtual navigation (생체신호 피드백을 적용한 가상주행 환경에서 사이버 멀미 감소 효과)

  • 김영윤;정찬용;김은남;윤정민;서동오;고희동;김현택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.90-94
    • /
    • 2002
  • 이전연구에서 가상현실에 몰입하는 동안 넓은 시야 (Field of view: 150$^{\circ}$)와 빠른 운행속도 (70 km/sec)가 사이버멀미를 심화시킨다는 결과를 얻었다: 피험자의 90%가 좁은 시야 (50$^{\circ}$)와 느린 운행속도 (30 km/sec)에서 사이버멀미 증상이 적었다. 본 실험에서는 피험자가 생리적인 동요를 경험할 때마다 바이오피드백 방법을 사용해서 사이버멀미 감소 가상환경 (cybersickness alleviating virtual environment, CAVE)을 제시한 후, 그 효과를 관찰하였다. 피부전도도, 말초체온, 말초혈류량, 심박률, 눈 깜박임, 뇌전위의 변수들을 입력으로 하는 인공신경망으로 구성된 실시간 멀미 탐지 시스템과 CAVE-제시 피드백 시스템을 구축하였다. 이 시스템은 생리적 측정치들이 사이버멀미의 출현을 신호할 때마다 피드백 출력으로 좁은 화면과 감소된 운행속도를 일시적으로 제공했다. 36명의 피험자를 대상으로 SSQ (simulator sickness questionnaires)와 자기보고를 이용하여 사이버멀미의 빈도와 심각도를 조사하였다. 모든 피험자는 한달 간격으로 CAVE 조건과 non-CAVE 조건에서 두 번 가상현실을 경험하였다. 사이버멀미의 빈도와 심각도는 non-CAVE 조건보다 CAVE 조건에서 유의미하게 감소하였다. 즉, 전기생리학적 특징들에 기반한 인공신경망에 의해 제공된 좁은 시야와 느린 운행의 가상환경은 사이버멀미 증상들을 의미있게 감소시켰다. 이러한 결과들은 생체신호 피드백 시스템을 이용하여 인간 친화적 가상환경을 구축할 수 있는 가능성을 보인 것이다.

  • PDF

Effect of Reaction Conditions on the Thiamine Decomposition by Bracken (고사리의 Thiamine 분해에 미치는 반응조건(反應條件)의 영향)

  • Yoon, Jae-Young;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.600-605
    • /
    • 1988
  • Antithiamine activity of raw and cooked brackens(Pteridium aquilinum) was evaluated under various reaction conditions by means of the thiochrome fluorescence method. The effects of caffeic acid and cysteine on the thiamine decomposition were also determined by thiochrome fluorescence and Lactobacillus viridescens bioassay methods. A water extract of raw bracken exhibited a high antithiamine activity which was increased with higher pH, temperature, incubation time and concentration of bracken. The influence of reaction conditions was less apparent in cooked bracken than in raw bracken. Caffeic acid stimulated the thiamine decomposition whereas cysteine showed a suppressive effect. The effect of cysteine was lower in the decomposition of thiamine by bracken extract.

  • PDF

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Biomechanics of Elliptical Trainer As an both Heat and Work - Related Experiment of a Fundamental Engineering Education : Energy Expenditure and Metabolic Cost (열과 일이 연관된 공학기초교육 실험으로써 Elliptical Trainers(ET) 생체역학 - 역학적 에너지 소비량 및 대사 소비량)

  • Hwang, Un-Hak
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.1
    • /
    • pp.146-153
    • /
    • 2010
  • The physics theory applied to the elliptical health trainers can be a good example in engineering education. From the point of view of the physics education the measurement of mechanical and thermal energy expenditure in elliptical trainers can be related to the muscle activity, quantity of motion, and metabolic cost. We realized that the low speed training is effective for high basal metabolism due to increasing the muscle activity even if the high speed training is effective for training down. Elliptical Trainer may provide an effective oxygen exhaustion and thus effective training down. However, the metabolic cost does not have much relation to the amount of training under the high speed of trainer.

  • PDF

Body composition by bioelectrical impedance analysis in children below 7 years old (7세 미만의 소아에서 생체전기저항법에 의한 체성분 분석)

  • Jung, Jiyoung;Kim, Han Wool;Kim, Tae Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.341-348
    • /
    • 2010
  • Purpose : Body composition is important to define and manage obesity and undernutrition. Obesity is a significant health problem with medical and psychological consequences for children and adolescents. Body composition analysis (BIA) is a simple, rapid, noninvasive, and reproducible technique. However, comparative analysis of body composition has not been done in young children below 7 years old. The aim of this study is to estimate antropometric data and body composition by BIA, and to investigate the correlation between anthropometric data and fat mass or fat percent in young children. Methods : We measured height, weight, body mass index (BMI), fat mass, and fat percent by BIA in 1,376 children aged 3-6 years of whom 688 were males and 688 were females. Results : Fat mass, fat percent, intracellular fluid, extracellular fluid, protein, and minerals were significantly higher in the obese group. A significant positive correlation exists between fat mass and BMI or weight. A significant positive linear correlation was also noted between fat percent and BMI. Protein, weight, fat mass, and fat percent were significantly different among groups. Conclusion : BIA is an objective, accurate method to estimate body fat in childhood obesity cases. Fat mass and fat percent data acquired by using BIA highly correlated with BMI. However, a large-scale study is needed to diagnose obesity in young children.

Bioavailability and Digestibility of Organic Calcium Sources by Bone Health Index (뼈건강 지표를 이용한 유기태 칼슘 급원의 생체이용성 및 소화율)

  • Han, Jeong-Ho;Kim, Eun-Mi;Cheong, Man-Ki;Chee, Sung-Kew;Chee, Kew-Mahn
    • Journal of Nutrition and Health
    • /
    • v.43 no.1
    • /
    • pp.12-25
    • /
    • 2010
  • This study was carried out to evaluate the bioavailabilities and the digestibilities of oligopeptide chelated (peptide-Ca), anchovy bone (anchovy-Ca) and methionine hydroxyl analogue (MHA-Ca) calcium compared to those of calcium carbonate in rats. In exp1, $CaCO_3$, were added to the basal diet at level of 0, 30 and 60% calcium of the AIN-93G diet. In test groups, peptide-Ca, anchovy-Ca and MHA-Ca, were added to the basal diet to provide calcium at the level of 40% of AIN-93G. In exp1, the bioavailabilities were evaluated from the regression equation of the ratios of theological/ actual calcium intakes of each dietary treatment. In exp2, urine and feces was to evaluate the true- and apparent digestibility and apparent retention. In exp1, Ca-60% group had higher bone mineral density (BMD), bone mineral content (BMC) and bone breaking strength (BBS) than those of the other standard groups. The bone weight and ash content of the peptide-Ca and anchovy-Ca groups were significantly higher than those of the MHA-Ca. Bone calcium content were not significantly different from the test group. The bioavailability of the MHA-Ca group was shown higher BMD (71%), BS (38%) and BBS (27%) compared to another control group. But the regression coefficient for BMD, BS and BBS were lower compare with that of bone ash and BMC. In exp2, the true- and apparent digestibility of test groups were shown to over 90%. Peptide-Ca was not significantly different from other test group, but digestibility and retention were higher compare to other test groups. In conclusion, peptide-Ca, anchovy-Ca and MHA-Ca improved Ca bioavailability in the rats. The compounds were higher Ca digestibility compared with those of $CaCO_3$. It is assumed that difference of digestibility for test groups may be correlated to the bioavailability of test groups in BMD, BMC, BS, BBS and bone ash respectively.