• Title/Summary/Keyword: 생체금속

Search Result 179, Processing Time 0.032 seconds

A Study of Biocompatibility of Acupuncture's Metal Materials - Focused on Biological Character (2) - (침 금속재료에 대한 생체적합성 연구 - 생물학적 특성을 중심으로(2) -)

  • Jung In-Tae;Kang Jung-Won;Baek Yong-Hyeon;Lee Sang-Hoon;Lee Jae-Dong;Choi Do-Young
    • The Journal of Korean Medicine
    • /
    • v.26 no.2 s.62
    • /
    • pp.166-175
    • /
    • 2005
  • Objecitve: To present criteria for acupuncture standardization, which will improve the quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture needles. Methods: Acupuncture needles distributed in Korea were studied. Acute poisonous tests and pyrogenicity materials tests were executed to study the biocompatibility of acupuncture needles. Results & Conclusions: All 3 brands of acupuncture needles commonly distributed in Korea were found suitable for medical use, through acute poisonous tests and pyrogenicity materials tests. However, the medical instrument standards of the Korea Food and Drug Administration for acupuncture lack criteria concerning acute poisonous tests and pyrogenicity materials tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

Studies on the Characteristics of Biological Samples under the Exposure of Trace Metals (Report 1) (미량금속 폭로에 있어 생체시료의 특성(제1보))

  • 김대선;김동술;이원창
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.79-88
    • /
    • 1991
  • These studies were carried out to find out some characteristic responses of biological samples under the exposure of trace metals. In animal experiment, six rats per week were killed for 6 weeks under Cd exposures and the concentrations of Cd, Cu and Zn in their organs and blood were determined by flame atomic absorption spectrophotometry.The results were summarized as follows: In animal experiments, the concentrations of Cd in the liver and kidney of Cd exposure groups were increased, however, the values of hematocrit and hemoglobin in blood were decreased remarkably. The body weight of the Cd exposure groups showed lower trend than that of control group. The concentrations of Cd in heart, lung and testes were increased slowly during the first 2 weeks. The concentrations of Cd in their organs decreased while the rapid increase of the concentration of Cd in the liver and kidney was observed. While rapid increase of the concentra~ion of Cd in the liver and kidney was observed, the concentrations of Cd in the organs were decreased afterward and increased again while the low increase of the concentration of Cd in the liver and kidney was observed. The concentrations Cu and Zn were increased remarkably in all the organs for first 2 and 3 weeks. In the exposure groups of Cd+Cu and Cd+Zn, the liver and kidney didn't show lower concentration of Cd than that of Cd group.

  • PDF

Comparative Biocompatibility of Metal Implants in Connective Tissue of Abdominal Wall of the Mouse (마우스의 복벽에서 결합조직에 대한 금속 이식체의 생체적합성 비교)

  • 김국렬;이민호;김병일;민병운;김명훈;최은상;조현욱
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study is to compare the biocompatibility of commercial purity Ti, Ti-6AI-4V and Ti-6AI-7Nb alloy specimens with and without surface treatment in mouse abdominal connective tissue in vivo. Each metal was implanted into specific abdominal subdermal tissue site of female mouse. After 4 weeks, the implants were removed and abdominal tissues were fixed, dehydrated and embedded in glycol methacrylate resin. And the tissues were histologically prepared for microscopical evaluation. It was characterized by the presence of connective tissue with fibrous capsule surrounding the implant. The fibrous tissue surrounding the implant was studied to determine the biocompatibility of implanted metals. The average thickness of the fibrous capsule formed around the implant was much thinner for the hydrogen peroxide added hydrochloric acid solution-treated specimen than for the others. The results of this evaluation indicate that modification of the surface properties of titanium and titanium alloy implants changes the biological properties in the abdominal connective tissue. In conclusion, these observations suggest that the proper surface treatment performed in the study is effective for the improvement of biocompatibility.

Current Status and Prospect of Nanopowder Technology (나노분말 기술의 현황 및 전망)

  • Park Jong-Ku
    • Proceedings of the Korea Environmental Mutagen Society Conference
    • /
    • 2005.05a
    • /
    • pp.27-39
    • /
    • 2005
  • 나노기술은 21세기 초반 첨단산업을 이끌어갈 핵심기술 중의 하나로 여러 나라들이 국가적인 차원에서 전략적으로 개발하고 있다 나노기술은 초정밀 가공기술, 원자 혹은 분자 단위의 조립(조합)기술, 소재공정기술 등의 기술 분야를 포함하며 나노스케일 영역에서 나노소재를 이용(제조 및 가공)하여 새로운 응용분야를 창출해 내거나 기존 산업을 더욱 고도화하는데 기여하는 기술이다. 나노소재는 금속, 세라믹, 고분자, 생체물질 등의 특정 물질 영역에 국한되지 않고 다양한 형태, 다양한 물성을 갖고 있으며 나노기술 구현에 있어서 직접적인 대상 혹은 중간매체에 해당한다. 따라서 나노소재 기술은 대단히 광범위한 영역을 포함하는 나노기술의 바탕을 이루는 기반기술 또는 원천기술이라고 할 수 있다. 여러 형태의 나노소재 중에서 가장 저차원(0차원)의 물질에 해당하는 나노분말은 기술적으로 가장 실용화에 근접해 있으며 이미 많은 상용화 사례들이 나타나고 있다. 나노분말 기술은 기술 성숙도 측면에서뿐만 아니라 확장성(유용성), 신규성(혁신성) 측면에서 대단한 가능성을 갖고 있기 때문에 향후 대단히 빠른 속도로 시장이 확대될 전망이다. 본 발표에서는 나노분말 기술의 개발 현황 및 전망에 대하여 언급하고자 한다.

  • PDF

A Study for Biocompatibility of Acupuncture′s Metal Materials, - Focused on Biological Character - (침 금속재료에 대한 생체적합성 연구 -생물학적 특성을 중심으로-)

  • Baek Yong-Hyeon;Chung In-Tae;Lee Sang-Hoon;Lee Jae-Dong;Choi Do-Young
    • The Journal of Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.180-190
    • /
    • 2004
  • Objectives : To present criteria for acupuncture standardization, which will improve quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture materials. Methods : Acupuncture needles distributed in Korea were studied. Intracutaneous reaction tests and sterility tests were executed to study the biocompatibility of acupuncture. Results & Conclusions : All 4 kinds of acupuncture needles distributed in Korea were found suitable for medical use, through intracutaneous reaction tests and sterility tests. However, the medical instrument standards of the Korea Food and Drug Administration lack criteria concerning intracutaneous reaction tests and sterility tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

Current Status and Prospect of Nanopowder Technology (나노분말 기술의 현황 및 전망)

  • Park, Jong-Ku
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2005.05a
    • /
    • pp.27-39
    • /
    • 2005
  • 나노기술은 21세기 초반 첨단산업을 이끌어갈 핵심기술 중의 하나로 여러 나라들이 국가적인차원에서 전략적으로 개발하고 있다. 나노기술은 초정밀 가공기술, 원자 혹은 분자 단위의 조립(조합)기술, 소재공정기술 등의 기술 분야를 포함하며 나노스케일 영역에서 나노소재를 이용(제조 및 가공)하여 새로운 응용분야를 창출해내 거나 기존 산업을 더욱 고도화하는데 기여하는 기술이다. 나노소재는 금속, 세라믹, 고분자, 생체물질 등의 특정 물질 영역에 국한되지 않고 다양한 형태, 다양한 물성을 갖고 있으며 나노기술 구현에 있어서 직접적인 대상 혹은 중간매체에 해당한다. 따라서 나노소재기술은 대단히 광범위한 영역을 포함하는 나노기술의 바탕을 이루는 기반기술 또는 원천기술이라고 할 수 있다. 여러 형태의 나노소재 중에서 가장 저차원(0차원)의 물질에 해당하는 나노분말은 기술적으로 가장 실용화에 근접해 있으며 이미 많은 상용화 사례들이 나타나고 있다. 나노분말 기술은 기술 성숙도 측면에서 뿐만 아니라 확장성(유용성), 신규성(혁신성) 측면에서 대단한 가능성을 갖고 있기 때문에 향후 대단히 빠른 속도로 시장이 확대될 전망이다. 본 발표에서는 나노분말 기술의 개발 현황 및 전망에 대하여 언급하고자 한다.

  • PDF

Growth of nanotubular oxide layers on Ti alloys with different alloying elements (Ti합금 표면에 생성되는 나노튜브 성장에 미치는 합금원소의 영향)

  • Kim, Min-Su;Gwon, A-Ram;Kim, Yeon-Ju;Kim, Yong-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.69.2-69.2
    • /
    • 2018
  • 전기화학적 양극산화법에 의해 형성하는 TiO2 나노튜브층은 넓은 비표면적과 규칙적인 구조를 가지고 있어 광촉매, 태양 전지, 생체재료 분야 등 다양한 분야에서의 응용이 되고 있으며, 국내 외 많은 연구가 보고 되고 있다. 특히, 나노튜브 층의 성장 거동에 미치는 인자로는 용액의 pH, 점도 등의 전해질의 물성, 인가전압, 시간 등이 있으며, 그에 대해 많은 연구가 이루어졌고 보고되고 있다. 최근 들어, 앞서 설명한 인자 이외에 양극산화에 사용되는 기판의 특성(미세구조, 결정구조, 결함, 첨가 원소 등)이 나노튜브층 성장거동에 영향을 미친다고 보고되었다. 따라서 본 연구에서는 전이금속으로 이루어진 Ti합금을 이용하여 첨가되는 합금원소가 산화막 성장 거동과 형태에 미치는 영향에 대해 조사 하였다. 본 연구에서는 Ti-Ni, Ti-Fe, Ti-Co 3종류 합금을 고진공 아크용해법으로 제조 하였으며, $1000^{\circ}C$에서 24시간 균질화 열처리를 하였다. 모든 합금은 최종 두께 2mm가지 냉간압연 하였으며, 양극산화는 동일한 조건에서 하였다. 생성된 나노튜브층의 표면 및 단면은 FE-SEM을 통해 관찰 하였다.

  • PDF

Thin Micro-Porous Scaffold Layer on Metallic Substrate (금속기질에 앓은 마이크로 다공질 스케폴드 코팅에 관한 연구)

  • Sin, D.C.;Miao, X.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.41-47
    • /
    • 2010
  • 티타늄과 티타늄 합금은 재료적 특이성 때문에 심장 혈관 임플란트에서 일반적으로 사용되어 왔다. 일찍이 적용된 예로는 인공심장판막, 심박조율기의 보호케이스, 혈액 순환 장치 등이 있다. 하지만 물질유도혈전증(Material-induced thrombosis)은 혈전폐색에 의해 기인한 기능 손실로 심장혈관 임플란트 장치의 주된 합병증으로 존재하고 있으며, 심장혈관 임플란트의 혈전유전자는 심장혈관장치의 발달에 주된 난관 중 하나로 남아있다. 그리고 텍스처 혈액 접합 물질(Textured blood-contacting material)은 1960년대 초반 이후부터 혈액순환 보조 장치의 임상실험에 사용되고 있다. 접합 물질에 내장된 텍스처 섬유조직 표면은 형성, 성장, 안정적 부착, 생물학적 내벽(neointimal layer) 등 유도 혈액(entrapping blood) 성분에 의해 형성된다. 공동(cavity) 형상의 용해 가능한 미립자를 사용하는 SCPL법(Solvent casting/particulate leaching method)은 티타늄 기질 이전에 형성된 폴리우레탄 위에 텍스처(texture)를 생성하기 위해 사용되었다. 또한 콜라겐의 부동화(不動化)에 의한 공동(cavity)은 혈액 접합면에 잔존하기 위한 내피세포를 고정할 수 있는 효과가 있다. cpTi로 층화된 PU 기소공성(microporous)은 구조적 특성과 혈전증 감소를 위한 생물학적 내벽 사용의 잠재성을 평가하기 위한 세포 공동체 실험을 통해서 평가되었다.

Zr-7Cu Alloy Design According to Sn Content for Bio-Metallic Materials (금속 생체재료를 위한 Sn 함량에 따른 Zr-7Cu 합금설계)

  • Kim, Min-Suk;Kim, Chung-Seok
    • Korean Journal of Materials Research
    • /
    • v.31 no.12
    • /
    • pp.690-696
    • /
    • 2021
  • The purpose of this study is to develop a zirconium-based alloy with low modulus and magnetic susceptibility to prevent the stress-shielding effect and the generation of artifacts. Zr-7Cu-xSn (x = 1, 5, 10, 15 mass%) alloys are prepared by an arc melting process. Microstructure characterization is performed by microscopy and X-ray diffraction. Mechanical properties are evaluated using micro Vickers hardness and compression test. The magnetic susceptibility is evaluated using a SQUID-VSM. The average magnetic susceptibility value of the Zr-7Cu-xSn alloy is 1.176 × 10-8 cm3g-1. Corrosion tests of zirconium-based alloys are conducted through polarization test. The average Icorr value of the Zr-7Cu-xSn alloy is 0.1912 ㎂/cm2. The elastic modulus value of 14 ~ 18 GPa of the zirconium-based alloy is very similar to the elastic modulus value of 15 ~ 30 GPa of the human bone. Consequently, the Sn added zirconium alloy, Zr-7Cu-xSn, is very interesting and attractive as a biomaterial that reduces the stress-shielding effect caused by differences of elastic modulus between human bone and metallic implants. In addition, this material has the potential to be used in metallic dental implants to effectively eliminate artifacts in MRI images due to low magnetic susceptibility.

Effect of Bleaching on Restorative Materials and Restorations-Review (치아미백제가 수복재와 수복물에 미치는 영향에 관한 고찰)

  • Shim, Youn-Soo;Choi, Jae-Yoon
    • Journal of dental hygiene science
    • /
    • v.6 no.3
    • /
    • pp.153-158
    • /
    • 2006
  • Bleaching of vital and nonvital teeth is becoming a more commonly used treatment in the dental office and at home. To improve appearance and remove discoloration, the teeth of specific patients are treated with a variety of bleaching agents. The typical bleaching agents contains carbamide or hydrogen peroxide as the active component. The purpose of the review article was to summarize and discuss the available information concerning the effect of peroxide releasing bleaching agent on dental restorative materials and restorations. Information from all original scientific full papers or reviews listed in PubMed or ISI Web Science were included in the review. Bleaching may exert a negative influence on restorations and restorative materials. Advice is provided based on the current literature to minimize the impact of bleaching treatment on restorative materials and restorations.

  • PDF