• Title/Summary/Keyword: 생식선량

Search Result 63, Processing Time 0.024 seconds

Control of Lycoriella ingenua (Diptera: Sciaridae) in Exports of King Oyster Mushroom, Pleurotus eryngii, using Ionizing Radiation (이온화에너지를 이용한 수출용 큰느타리버섯의 긴수염버섯파리 방제)

  • Hyeonmo Ahn;Sun-Ran Cho;Hyun-Na Koo;Gil-Hah Kim
    • Korean journal of applied entomology
    • /
    • v.62 no.4
    • /
    • pp.333-343
    • /
    • 2023
  • King oyster mushrooms are one of the major fresh agricultural products which their exports are increasing every year in Korea. Lycoriella ingenua, is notorious insect pest in agriculture, especially in mushroom production. Larvae of L. ingenua cause mainly direct crop damage and adults are vectors of several dangerous fungal pathogens. In this study, the effects of electron beam, X-ray, and gamma-ray irradiation on the development and reproduction of L. ingenua were evaluated. In addition, to find the optimal dose to control L. ingenua in a box filled with king oyster mushrooms, an empirical experiment was conducted for each radiation. As a result, the development and reproduction of L. ingenua were inhibited at 50 Gy for all electron beam, X-ray, and gamma-ray irradiation. Additionally, at the top, middle, and bottom of the export box filled with king oyster mushrooms, the development and reproduction of L. ingenua were inhibited by electron beam with 150 Gy, X-ray with 100 Gy, and gamma-ray with 50 Gy. These results can be provided as basic data for establishing an integrated quarantine management system when exporting mushrooms. It will also contribute to the safety of agricultural products and the strengthening of export competitiveness.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray (진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석)

  • Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

Effect of Electron Beam Irradiation on the Development and Reproduction of Phthorimaea operculella (Lepidoptera: Gelechiidae) (전자빔 조사가 감자뿔나방의 발육과 생식에 미치는 영향)

  • Cho, Sun-Ran;Ahn, Hyeonmo;Eom, Taeil;Kyung, Yejin;Lee, Seung-Ju;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.60 no.2
    • /
    • pp.255-262
    • /
    • 2021
  • The potato tuber moth, Phthorimaea operculella (Zeller) has been known as a quarantine pest of potato. This study investigated inhibition doses of electron beam irradiation (EBM) by comparing their effects on the development and reproduction and DNA damage of the insect pest. Eggs (0-12 h old), larvae (3rd and 5th instar), pupae (less than 1 d old after pupation) and adults (less than 1 d old after emergence) were irradiated with increasing doses of EBM. The EBM with 150 Gy could not completely prevent the hatchability of eggs and pupation of the hatched larvae. The hatchability from the irradiated eggs were 19.3%. However, adult emergence from the irradiated eggs were completely inhibited. When 3rd and 5th instar larvae were irradiated at 100 Gy, the adult emergence from the irradiated larvae and the fecundity of the adults were completely inhibited. When pupae and adults were irradiated at 300 Gy and 400 Gy, respectively, the hatchability of the F1 eggs was completely inhibited. The alkaline comet assay on the level of DNA damage by EBM in P. operculella adults indicates that the EBM increased DNA damage level in a dose-dependent manner, and the damage was repaired in a time-dependent manner. These results may recommend EBM of 150 Gy as a phytosanitary treatment for P. operculella. However further confirmative study is required for the practical application of this EBM dose for P. operculella disinfestation.

Failure Pattern of Pineal and Ectopic Pineal Germ Cell Tumor after Gamma Knife Radiosurgery (송과선 및 이소성 송과선 생식세포종의 감마 나이프 수술 후 재발 양상)

  • Cho, Heung-Lae;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.92-100
    • /
    • 2000
  • Purpose :This study was performed to determine the optimal treatment velum of Patients treating with radiation therapy for intracranial germ cell tumor. Materials and Methods : From 1993 to 1998, 19 patients with intracranial germ cell tumors treated by gamma knife radiosurgery were analyzed. The location of tumor was as follows; 9 cases on pineal region, 1 case on suprasellar region, and 9 cases of multiple lesion. 7 patients were pathologically verified; 5 cases of germ cell tumor and 2 cases of non germinomatous germ cell tumor. Tumor volume was ranged from 2.4 cm$^{3}$ to 74 cm$^{3}$. Irradiation dose was 10 Gy to 20 Gy with 50% isodose curve. Follow up period was 10 months to 54 months. Results : Recurrences were observed in 14 cases among 19 (74%) patients. Complete remission and partial remission were achieved in 2 (11%) and 10 (53%) respectively. No response was observed in 7 (36%). 2 cases were recurred within original tumor bed. 6 cases were recurred beyond but contiguous with tumor bed. Ventricular relapses separated from pretreatment tumor bed were 3. Spinal recurrences were 4. Among 8 recurred cases of which tumor volume is smaller than 20 cm$^{3}$, 2 were recurred within original tumor bed, 4 were recurred beyond but contiguous with tumor bed, and 1 spinal recurrence. Meanwhile, 6 cases of which tumor volume larger than 20 cm3, 1 case was recurred beyond but contiguous with tumorbed, 2 ventricular recurrences separated with original tumor bed, and 3 spinal recurrences. 5 cases which did not show any recurrence sign showed characteristics of single lesion, tumor volume smaller than 20 cm$^{3}$ and normal tumor marker. All of 4 cases of spinal recurrences happened in the case having ventricular invasion or lesion. Among 9 cases having multiple lesion, only 3 cases recurred within original tumor bed or around tumor bed, the other 6 cases recurred separated from pretreatment tumor bed. Conclusion : Gamma knife radiosurgery is not recommended for the treatment of intracranial germ cell tumor. It is because of small treatment volume and inadequate radiation dose that are characteristics of gamma knife radiosurgery. Tumor volume, ventricular invasion or ventricular lesion in multiple lesion are important factors to be considered for the wide field radiation therapy Tumor volume smaller than 20 cm$^{3}$, single lesion, no ventricular lesion or invasion, and normal tumor marker are ideal indications for small involved field radiation therapy. Prophylactic spinal irradiation seems to be necessary when there is ventricular lesion, ventricular invasion, and multiple lesions. When the tumor volume is larger than 20 cm$^{3}$, multiple lesions, abnormal tumor marker, and whole ventricular irradiation or partial brain irradiation would be possible and neoadjuvant chemotherapy would be most beneficial in these group.

  • PDF

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

A Study on Perceptions by College Students of Radiology about the Knowledge, Attitudes and Behaviors of Radiation Exposure Management (방사선과 대학생이 방사선피폭관리에 대한 지식, 태도, 행위에 관한 연구)

  • Yeo, Jindong;Ko, Inho;Kim, Hye-Sook
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.79-99
    • /
    • 2015
  • Participants of this study were students of radiology who were attending colleges or universities located in Daegu and Gyeongbuk. This researcher conducted a questionnaire survey of those students from Feb. 3rd to 21st, 2014. The findings of the study can be summarized as follows. 1. Concerning the knowledge of radiation exposure management, the respondents' scores were highest in two items, or 'Materials based on lead or concrete may shield X-rays' and 'The sexual gland is very sensitive to radiation' and lowest in the item which says' 'Occupational radiation exposure dose should not exceed 20mSv a year in average on a 5-year period basis'. 2. The participants' scores for the attitudes of radiation exposure management were higher in two items, or 'Health examination should be made regularly in relation to radiation exposure' and 'Those who work within the area of irradiation should wear protective clothes' and lowest in the item which says 'Radiation exposure dose should be regularly measured for the calibration of the radiation system'. 3. For the behaviors of radiation exposure management, the surveyed students showed highest scores in two items, or 'When irradiating the patient, the radiator should be behind the protective barrier(plate)' and 'It is needed to receive the education of radiation exposure management regularly' While, their score for a behavior described in the item saying 'Before using the radiation system, it is needed to check whether the machine works normally.

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.

Application of Electron Beam Irradiation for Insect Pest Control in Agricultural Products Quarantine [Case study: Myzus persicae and Planococcus citri (Risso)] (농산물 수출입 검역시 병해충 방제를 위한 전자선 조사기술의 응용(사례연구: 귤가루깍지벌레와 복숭아혹진딧물))

  • Lee, Gyeong-Ae;Park, Min-Goo;Cho, Jae-Young
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.2
    • /
    • pp.141-144
    • /
    • 2014
  • The effects of electron beam irradiation on control of Myzus persicae and Planocococcus citri (Risso) were evaluated with the changes of mortality, emergence rate, fecundity, and egg hatchability. As a result of this study, M. persicae and P. citri (Risso) was not directly affected by electron beam irradiation with low doses (30, 60, 90, and 120 Gy) but the irradiation had effects on inhibition of development and reproduction of the pests.

Induction of Two Types of Gynogenetic Diploid of Sweet Fish, Plecoglossus altivelis and Verification by Isozyme Marker (은어 2종류의 자성발생 2배체의 유도와 Isozyme 유전자에 의한 배수성의 확인)

  • 손진기
    • Development and Reproduction
    • /
    • v.4 no.1
    • /
    • pp.79-85
    • /
    • 2000
  • This study was made to optimize the conditions needed to produce two types of gynogenetic diploids in the sweet fish, Plecoglossus altivelis. Firstly, ultraviolet (UV) ray doses between 3,000 erg to 14,000 erg/$\textrm{mm}^2$ were tested to inactivate sperm genetically. Based on the appearance of the haploid syndromes in the embryo, a dose of UV ray 6000~7000 erg was required to inactivate sperm genetically. Then, cold shock treatment at 1~2$^{\circ}C$ for 15~30 min were conducted to retain the 2nd polar body in inseminated egg. The best elapsed time before the start of the cold shock was examined between 5~8 min. The experiments in which began 5 min after insemination at 1~2$^{\circ}C$ during 17.5 min gave 21.2% survival rate and 89.7% normal eyed embryo rate. The gynogenetic diploid produced by suppression of the first cleavage, a considerably high number of heteroploids appeared and high mortality was observed at the metamorphosis stage, so further investigation is needed. The production of gynogenetic diploids were confirmed by GPI isozyme marker. The heterozygous type in Gpi-1 locus was observed in the meiotic-G2N as a result of gene-centromere recombination during meiosis. The heterozygous type was never observed in mitotic-G2N and showed segregation into two homozygous types at Gpi-1 locus.

  • PDF