• 제목/요약/키워드: 생물막 공정

검색결과 177건 처리시간 0.031초

하수재이용 공정에서 발생되는 RO농축수 처리를 위한 MBR 공정 적용 (Application of MBR process for the treatment of RO concentrate from wastewater reuse process)

  • 이도헌;장현지;김한승
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.339-349
    • /
    • 2013
  • Biological treatment of RO concentrate from wastewater reuse process is known to be very difficult due to its high concentration of non-degradable organics and salt ions such as chloride, nitrate and phosphate. In this research, the treatment performance of MBR was examined using RO concentrate mixed with raw wastewater as the influent of MBR. Addition of PAC (powdered activated carbon) to MBR was also evaluated in order to enhance the treatment performance and stability. The performance of MBR for treating only RO concentrate decreased gradually although external carbon source was added. The average removal performance of MBR with and without PAC decreased from 99.1 %(98.8 %) to 94.9 %(91.4 %) for COD, 81.3 %(80.3 %) to 42.0 %(41.9 %) for T-N and 57.3(55.0 %) to 30.0 %(21.0 %) for T-P with the increase of RO concentrate mixing rate of 0 % to 20 % in the feed water. Addition of PAC showed positive effect on the performance of MBR for the removal of COD and phosphorus in case that the ratio of RO concentrate to feed water increased.

생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석 (Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor)

  • 박태영;최창규
    • 대한환경공학회지
    • /
    • 제37권3호
    • /
    • pp.152-158
    • /
    • 2015
  • 본 연구는 소수성 막 재질에 대한 막오염도를 평가하고자 수동흡착의 개념을 도입하여 정상운전을 위한 막 모듈 이외에 수동흡착 시험용 막 모듈을 설치하여 유출을 시키지 않은 상태에서 막 표면에 부착되는 미생물에 의한 막오염 정도를 분석함으로써 소수성 막오염 잠재성을 평가하고자 하였으며, 이때 운전조건으로 유기물 유입부하를 변화시켜 평가하였다. 이와 더불어 오염된 멤브레인을 세 가지 세정방법(두가지 물리적 세정과 화학적 세정)을 통해 막 세정 전후의 막오염 회복률을 평가하였다. 막오염 평가인자로는 반응조 내 MLSS 농도와 EPS 농도를 조사하였으며, 여과저항 값을 산정하여 막오염 전과 후, 세정 3단계 전과 후를 비교 평가하였다. 실험 결과로서, COD 농도가 750 mg/L인 가장 높은 부하량 조건에서 반응조 내 EPS 농도와 수동흡착 시험용 멤브레인의 여과저항 값이 가장 높게 나타났다. 또한 여과저항 값이 초기 운전 시작 후 차이를 보였지만 60일 이후의 최종 여과저항은 거의 일정하게 나타났는데, 이는 막 표면에 부착된 미생물량이 임계점에 이르러 수동흡착만으로는 더 이상의 막오염은 진행되지 않은 것으로 판단된다. PAds 상태에서 유기물 유입부하에 따른 오염된 막의 세정 전후의 여과저항 측정 결과에서는 3단계 세정 후 평균 회복률이 각각 Run 1이 78%, Run 2가 72%, Run 2가 69%로 유기물 부하가 높을수록 회복률이 떨어지는 것으로 나타났으며, 반면에 물리적 세정에 의한 복원률이 40일 경부터 Run 2와 Run 3의 물리적 세정에 의한 회복률이 낮아지는 것으로 보아 높은 유기물 부하로 인한 막표면의 케이크 형성으로 막오염이 심화된 것으로 판단된다.

영가철과 활성슬러지를 이용한 독립영양방식의 퍼클로레이트 제거: 회분배양연구 (Autotrophic Perchlorate-Removal Using Zero-Valent Iron and Activated Sludge: Batch Test)

  • 안영희;하명규
    • 생명과학회지
    • /
    • 제21권3호
    • /
    • pp.444-450
    • /
    • 2011
  • 퍼클로레이트($ClO_4^-$)는 지표수 및 토양/지하수에서 검출되는 오염물이다. 독립영양방식의 퍼클로레이트-환원세균(PRB)은 기체 수소(H2)를 전자공여체로 사용하여 $ClO_4^-$를 제거한다. 철이 부식되면 $H_2$를 생성할 수 있음에 착안하여 본 연구에서는 하수처리장에서 쉽게 구할 수 있는 활성슬러지를 식종하여 영가철(ZVI)을 이용한 독립 영양방식의 $ClO_4^-$ 제거 가능성을 조사하였다. 회분반응실험을 통해 활성슬러지미생물이 ZVI가 존재할 때 $ClO_4^-$를 분해할 수 있음을 알 수 있었으며, 또한 이러한 $ClO_4^-$의 생분해는 $ClO_4^-$가 분해됨에 따라 생성되는 $Cl^-$의 몰 농도를 통해 확인 할 수 있었다. 독립영양방식의 $ClO_4^-$ 제거공정에 사용된 철 입자의 표면에 간균형태의 미생물들이 존재한다는 것을 주사전자현미경을 통해 관찰하였다. 그래서 철 입자가 생물막을 형성하기 위한 담체로서도 작용할 수 있다는 것을 알 수 있었다. ZVI가 첨가된 $ClO_4^-$ 분해성 농화배양으로부터 채취한 생물막의 미생물군집조성은 접종균으로 사용된 활성슬러지의 그것과는 다름이 DGGE 분석 결과 나타났다. DGGE band 중에서 생물막의 주요밴드는 Clostridia 강과 가장 관련이 있는 것으로 나타났다.

암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구 (A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane)

  • 강희석;이의종;김형수;장암
    • 상하수도학회지
    • /
    • 제28권2호
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

MBR 공정에서 물리세정 조건에 따른 막 오염 제어 성능 평가와 현장 적용성에 관한 연구 (Evaluating membrane fouling and its field applicability under different physical cleaning conditions in MBRs)

  • 박정훈;김형수;박기태;박정우;박세근;강희석;김지훈
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.605-612
    • /
    • 2016
  • Membrane bioreactors (MBRs) employ a process of biological treatment that is based on a membrane that has the advantages of producing high-quality treated water and possessing a compact footprint. However, despite these advantages, the occurrence of "fouling" during the operation of these reactors causes the difficulty of maintenance. Hence, in this study, three physical cleaning methods, namely, backwashing, air scrubbing, and mechanical cleaning ball was performed to identify optimum operating conditions through laboratory scale experiments, and apply them in a pilot plant. Further, the existing MBR process was compared with these methods, and the field applicability of a combination of these physical cleaning methods was investigated. Consequently, MCB, direct control of cake fouling on the membrane surface was found to be the most effective. Moreover, as a result of operating with combination of the physical cleaning process in a pilot plant, the TMP increasing rate was found to be - 0.00007 MPa/day, which was 185% higher than that obtained using the existing MBR process. Therefore, assuming fouling only by cake filtration, about one year of operation without chemical cleaning is considered to be feasible through the optimization of the physical cleaning methods.

탄소중립을 지향하는 전기화학적 이온 분리(EIONS) 기술 (Electrochemical Ion Separation Technology for Carbon Neutrality)

  • 주화주;안재욱;전성일;윤제용
    • 공업화학
    • /
    • 제34권4호
    • /
    • pp.331-346
    • /
    • 2023
  • 탄소중립 달성을 위해 에너지 효율적이고 전기화된 사회에 직접 이용될 수 있는 친환경 공정이 주목받고 있다. 다량의 에너지를 소모하는 기존의 열 및 압력 기반의 담수화 기술에서도 이는 예외가 아니기에, 최근 차세대 전기화학 기반 담수화 기술들의 성장이 두드러진다. 대표적으로 에너지 저장 장치의 구동 원리를 기반으로 하는 전기화학적 이온 분리(electrochemical ion separation, EIONS) 기술이 있으며, 여기에는 축전식 탈염(CDI) 기술과 배터리 담수화 시스템(BD)가 포함된다. EIONS 기술에는 시스템 성능 향상을 위해 CDI와 BD를 기본으로 한 다양한 응용 시스템들이 개발되어 왔는데, 이러한 결과물들의 의미와 독창성을 배경지식 없이 한눈에 파악하기 매우 어렵다. 따라서 우리는 이 리뷰 논문에서 EIONS 연구에서의 지난 몇 년간의 기술적 진보와 시스템 개별 특성을 각 시스템의 구동원리, 연구 배경, 장단점을 중심으로 명확하고 구체적으로 설명하고자 한다. 아울러, EIONS의 미래 발전과 연구 방향을 설명하며 리뷰 논문을 마무리하겠다. 이 논문을 통해 EIONS 연구를 막 시작하는 연구자들이 EIONS의 연구 동향을 보다 쉽게 파악할 수 있을 것이다.

단백질 추출용 역미셀 실관막장치에 관한 연구 (Reversed Micellar Protein Extraction in a Hollow Fiber Membrane Extractor)

  • 윤현희;박상준유인상
    • KSBB Journal
    • /
    • 제9권3호
    • /
    • pp.332-338
    • /
    • 1994
  • 역미생용액으로 단백칠을 추출하는 공정에셔 수용 액의 이온세기와 pH가 중요한 공정변수가 된다. 본 실험에셔 사용한 역미생용액은 AOT를 Isooctane에 5 50mM의 농도로 용해시켜 사용하였고 단백칠로서 alkaline protease를 model compound로 사용하여 추출설험을 수행한 결과 본 설험의 범위에서 pH가 낮을수록, 이온세기가 낮을수록 효율적인 추출이 이루어졌으며, pH가 3.0 그리고 이온세기가 O.lM KCI 일때 분배계수가 4.0으로 가장 크게 나타났다. 단백질의 용매추출 장치로서 설관막 모률을 제작 하여 alkaline protease를 역미생을 이용하여 용매 추출을 수행하였는 바, 단백질 분리공정에 효과적인 장치로 사용될 수 었음을 보여주였다. 본 실험의 조 건에서 총괄물질전달계수 Ko가 $6.7{\times}10^{-5}cm/s$이었으며 유기용매상의 개별물칠전달저항이 수용액상의 물질전달저항보다 중요하게 나타났다. 실관막 추출 장치의 조업시 설관막 양쪽 상의 압력차를 $0.1kg/cm^2$. 이하로 조절하여 emulsion의 형성을 방지할 수 있었다.

  • PDF

간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성 (Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB))

  • 허목;강진영;김광진
    • 유기물자원화
    • /
    • 제11권2호
    • /
    • pp.125-131
    • /
    • 2003
  • 본 연구는 오수중의 유기물 및 질소 인의 동시제거를 위한 오 폐수 고도처리장치인 간접폭기형 침적생물막여과장치(Indirected Aerated Submerged Biofilter : INSUB)를 개발하기 위하여 실험실적 모형실험을 수행하였다. INSUB에서 오수를 처리함에 있어서, HRT 18시간, 공탑속도 42.5m/hr, 충전율 40%인 경우가 실제로 경제적인 효율을 고려하였을 때, 가장 효율이 좋았다. 각각의 제거효율을 살펴보면, $COD_{cr}$, 90.6%, $COD_{Mn}$ 85.3%, $BOD_5$ 95.0%, T-N 52.3% 그리고 T-P 56.8%로 나타났다. 질소 인의 고효율처리를 위해서는 전탈질공정에 의한 산화질소의 제거를 위해 무산소, 호기조의 조합 등에 의한 system의 일부 다단화가 필요함을 확인할 수 있었다.

  • PDF

이온 보조 반응에 의하여 활성화된 폴리프로필렌 담체를 이용만 합성폐수 처리시 미생물 부착 및 유기물의 제거 (Microbe Adhesion and Organic Removal from Synthetic Wastewater Treatment using Polypropylene Media Modified by Ion-Assisted Reactions)

  • 선용호;한성;고석근
    • KSBB Journal
    • /
    • 제17권3호
    • /
    • pp.235-240
    • /
    • 2002
  • 친수성 표면을 만들기 위하여 산소분위기에서 1 keV의 에너지를 갖는 아르곤 이온빔을 폴리프로필렌 담체의 표면에 조사하였다. 삼차 증류수에 대한 접촉각은 개질 전의 $78^{\circ}$에서 최적의 조건에서 $22^{\circ}$까지 감소하였다. 이온 보조 반응 후의 친수성 증가는 ether, carbonyl, carboxyl 등의 새로 형성된 작용기에 의한 것이며 극성 용매에 대한 안정성이 우수하므로 활성화된 표면이 폐수 내에서도 안정하다. 활성화된 폴리프로필렌 담체를 합성폐수내의 유기물을 제거하기 위한 bio-film공정에 적용하였다. 이온 보조 반응법으로 친수성 표면으로 개질된 PP 담체는 극성 용매내에서 극성작용기가 유지되었으므로 안정된 표면 특성을 이용하여 박테리아 부착의 생물막 공정에 대한 연구를 수행하여 미생물의 부착은 표면의 염기성 극성작용기에 의하여 증진됨을 확인하였다. 합성폐수에 대한 처리 효율은 30%까지 증가 하였으며 장시간에 걸친 COD 농도 감소 효과를 나타내었으므로 이온 보조 반응법에 의하여 처리된 PP고분자를 수질 개선용의 담체로 사용하여 처리효율을 증가시킬 수 있음을 확인하였다.

역삼투 해수담수화 공정 내 바이오필름 형성 미생물의 부착 및 고압내성 특성 (Adhesion Characteristics and the High Pressure Resistance of Biofilm Bacteria in Seawater Reverse Osmosis Desalination Process)

  • 정지연;이진욱;김성연;김인수
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.51-57
    • /
    • 2009
  • 역삼투 해수담수화(SWRO)공정의 큰 문제점 중 하나인 biofouling 현상을 초기에 감지하기 위한 센서 개발의 선행 연구로써, 본 연구는 역삼투막에 바이오필름을 형성하는 문제성 있는 박테리아를 센서의 타겟 박테리아로 제시하는 것에 중점을 두었다. 문헌조사와 실제 해수담수화 공정에서 사용된 해수 원수와 오염된 역삼투막에 존재하는 박테리아를 계통발생학적으로 분석한 결과를 토대로 Bacillus sp., Flavobacterium sp., Mycobacterium sp., P. aeruginosa, P. fluorescens, 그리고 Rhodobacter sp.의 여섯종의 모델 박테리아를 선정하였고, 선정된 모델 박테리아 중, 막 오염 잠재력을 가진 종을 찾아내기 위해 각각 박테리아의 역삼투막 부착 능력, 고압내성, 그리고 소수성을 비교 분석하였다. 그 결과, 역삼투막 부착능력은 Rhodobacter sp.와 Mycobacterium sp.가 뛰어났으며 소수성이거나 역삼투막(접촉각 약 $63^{\circ}$)과 비슷한 접촉각을 가진 박테리아가 역삼투막에 잘 부착하였다. 800 psi의 고압을 적용 한 후, Rhodobacter sp.는 여섯 종류의 모델 박테리아 중 59-73%의 가장 큰 개체수의 감소를 보였고, P. fluorescens는 1-29%로 가장 높은 고압내성을 보였다. 부착, 소수성, 고압내성 특성을 통한 역삼투막에 biofouling을 유발하는 영향력 있는 박테리아 선정 실험 결과, 여섯 종류의 모델 박테리아 중 Mycobacterium sp.가 부착 능력이 뛰어나고 높은 소수성 특성을 가지며, 800 psi의 고압에서도 50% 이상의 cell의 생물학적 활성능력을 가지고 있어, 막 오염을 유발시키는 가장 잠재력 있는 박테리아로 분석되었다.