• Title/Summary/Keyword: 샘플 측정

Search Result 1,135, Processing Time 0.033 seconds

Comparison of Sampling Techniques for Passive Internet Measurement: An Inspection using An Empirical Study (수동적 인터넷 측정을 위한 샘플링 기법 비교: 사례 연구를 통한 검증)

  • Kim, Jung-Hyun;Won, You-Jip;Ahn, Soo-Han
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.34-51
    • /
    • 2008
  • Today, the Internet is a part of our life. For that reason, we regard revealing characteristics of Internet traffic as an important research theme. However, Internet traffic cannot be easily manipulated because it usually occupy huge capacity. This problem is a serious obstacle to analyze Internet traffic. Many researchers use various sampling techniques to reduce capacity of Internet traffic. In this paper, we compare several famous sampling techniques, and propose efficient sampling scheme. We chose some sampling techniques such as Systematic Sampling, Simple Random Sampling and Stratified Sampling with some sampling intensities such as 1/10, 1/100 and 1/1000. Our observation focused on Traffic Volume, Entropy Analysis and Packet Size Analysis. Both the simple random sampling and the count-based systematic sampling is proper to general case. On the other hand, time-based systematic sampling exhibits relatively bad results. The stratified sampling on Transport Layer Protocols, e.g.. TCP, UDP and so on, shows superior results. Our analysis results suggest that efficient sampling techniques satisfactorily maintain variation of traffic stream according to time change. The entropy analysis endures various sampling techniques well and fits detecting anomalous traffic. We found that a traffic volume diminishment caused by bottleneck could induce wrong results on the entropy analysis. We discovered that Packet Size Distribution perfectly tolerate any packet sampling techniques and intensities.

집속체의 선밀도 변동성과 데이터 샘플링

  • Heo, Yu;Kwak, Do-Woong;Kim, Jong-Sung;Kim, Seung-Hoon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.46-46
    • /
    • 2004
  • 디지털 측정장치의 발달에 따라 센서에서 출력되는 아날로그 신호를 디지털 신호로 변환하고, 이를 바탕으로 측정결과를 제시하는 경우가 많다. 그러나 아날로그 신호의 디지털화 과정에서는 정보의 유실이 생길 수밖에 없고, 또한 측정 헤드의 dimension 과 sampling interval 등과 같은 측정조건은 측정결과의 신뢰성에 많은 문제를 야기 시킨다. 본 연구에서는 새로운 측정방법을 바탕으로 시장-분산곡선과 Correlogram 법을 이용하여 그 특성을 해석하고, 데이터 샘플링 시 측정조건과 시료내의 변동성이 측정결과인 평균 굵기 및 굵기의 총분산에 미치는 영향을 찾아 보았다.(중략)

  • PDF

The Effect of Sampling Frequency and Pulse Bandwidth on Estimating Mean Frequencies in an Ultrasonic Doppler System using the Second-Order Sampling (2차 샘플링을 이용한 초음파 도플러 시스템에서 샘플링 주파수 펄스 대역폭이 평균 주파수 측정에 미치는 영향)

  • Ahn, Young-Bok;Park, Song-Bai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.48-55
    • /
    • 1990
  • We analyze the effect of second-order sampling on estimating the mean frequency of the Doppler signal. In order to reduce the sampling frequency of analogue-to-digital converter, it is possible to obtain the Doppler signal by sampling the radio frequency echo signal with the low frequence of $4f_0$/5 or $4f_0$/9 instead of $4f_0$, where $f_0$ is the center frequency of the transmitted signal. The computer simulation and experiments show that if the narrowband signal is transmitted as is usual in the Doppler system, the error of the mean frequency estimates due to the low sampling frequency is negligible.

  • PDF

$Ar/O_2$가스비에 따른 (Ba,Sr)$TiO_3$ 박막의 유전특성에 관한 연구

  • 이태일;박인철;김홍배
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.99-99
    • /
    • 2000
  • 본 논문에서는 RF Magnetron Sputtering 방법으로 Ba0.5Sr0.5TiO3 박막을 Pt/Ti/SiO2/Si 기판위에 증착하였다. Ar과 O2의 가스비는 90:10부터 50:50까지 O2의 함유비율을 10씩 증가시켰으며, 모든 조건에서 증착온도는 실온으로 설정하였다. Ba0.5Sr0.5TiO3 박막의 증착후 각 가스비에 따른 동일한 샘플에 대해 RTA(Rapid Thermal Anneal) 장비를 이용하여 $600^{\circ}C$에서 열처리는 하여 열처리 효과에 대한 특성도 조사하였다. 최종적으로 제작한 BST 커패시터는 Pt/BST/Pt 구조를 갖는 MIM(Metal-Insulator-Metal) 구조의 커패시터였으며 상.하부 전극은 전기적 특성이 우수한 Pt를 사용하였다. 제작된 BST 커패시터를 대해 유전 특성을 조사하기 위해 C-V 측정을 한 결과 산소 함유량이 증가함에 따라 유전율의 증가를 보여주었으며, 제작된 샘플 중 산소 함유량이 30인 샘플은 300이상의 우수한 유전율을 나타내었다. 또한 누설 전류특성에서는 모든 샘플에 대해 1.0V의 인가전압에서 1.0$\times$106A/cm2 이하의 누설 전류 밀도 값을 가져 전기적으로도 안정된 커패시터 구조임을 확인하였다. 또한 막의 증착상태와 미세구조관찰을 위해 SEM 측정을 하였고 구성성분 결정 구조를 알기 위해 XRD 측정도 시행하였다. 결과적으로 본 논문에서 제작된 커패시터 중 Sr/O의 비율이 70:30인 샘플이 가장 우수한 유전특성을 나타내었고, 이 샘플의 유전특성과 누설 전류 특성은 차세대 메모리인 1GigaByte급 DRAM에 적용 가능한 조건들을 만족시켰다.

  • PDF

Micro Vibration Measurement in a Latex Sample Mimicking the Tympanic Membrane Using Micro Vibro Tomography (고막을 모방한 라텍스 샘플의 미세진동 측정을 위한 마이크로 바이브로 토모그라피 시스템 개발)

  • Kwon, Jaehwan;Kim, Pilun;Jeon, Mansik;Kim, Jeehyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2019
  • In this paper, we propose a micro vibro tomography(MVT) method, that can be used to visualize two-dimensional cross-sectional images and micro-vibration tomographic images in real time in a non-contact and non-destructive manner. The proposed method is based on the optical coherence tomography(OCT) technique, with an additionally customized image processing algorithm. The proposed method can detect the micro-motions or vibrations in sample structures by measuring the phase shift variations in the sample structures. In this study, we show the potential capabilities of the proposed MVT system for measuring the micro-vibrations generated when sound waves in a frequency range of 2~5 kHz are applied to an $80-{\mu}m$ thick latex phantom, which mimics the changes in physical structure of the human tympanic membrane while hearing. Additionally, three-dimensional volumetric images of the MVT method were recorded to observe the surface morphological changes in the surface of the phantom sample which mimics the human tympanic membrane while hearing.

Study of Cross Correlation Using DRS(Delayed Reference Sample) for Precision Time Measurement of Input Signal on Multilateration (다변측정감시시스템 신호 입력 시각 정밀 측정을 위한 DRS(Delayed Reference Sample)를 이용한 Cross Correlation 방안 연구)

  • Chang, Jae-Won;Lee, Sang Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.244-250
    • /
    • 2018
  • Multilateration acquires the transponder signal of target from receivers installed on the ground and calculates the position of the target using the difference of the signal acquisition time of each receiver. One of the factors that influence the positioning accuracy of Multilateration using the TDOA calculation method is the error due to the precision measurement of signal input time. When measuring the signal input time at the receiver, the input signal is sampled using the reference clock of the receiver and a reference sample having the same sampling rate is applied to the cross correlation technique. Therefore, the accuracy of the signal input time is proportional to the reference clock. In this paper, the algorithm for precisely measuring the signal input time by performing cross correlation between the input signal of the receiver and DRS(Delayed Reference Sample) is proposed. In order to verify this, we implemented the pulse signal of the transponder that is transmitted from the target using Matlab. Through the simulation, cross correlation between the proposed DRS and the input signal was performed. From this result, the performance of the precise measurement of signal input time was analyzed.

Development and Evaluation Performance of Multi-Stage Aerosol Concentrator (다단 입자농축기의 개발 및 성능평가)

  • 김민철;김대성;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.359-360
    • /
    • 2000
  • 대기 중에 부유하는 입자상 물질의 샘플링은 다양한 방법을 통해 이루어지고 있다. 현재 사용되고 있는 임자 샘플러(sampler)는 대부분 관성력 또는 원심력을 이용하여 입자를 크기별로 분류하고 있다. 하지만 입자의 농도가 아주 낮아 대표적인 샘플링을 하기가 어려운 경우에는 장시간의 샘플링과 대용량의 유량이 필요하다. 저농도로 부유하는 오염물질을 신속하게 측정하기 위해서는 낮은 농도를 고농도로 농축하여 측정기기에 실시간(real-time)으로 보내는 기술이 필요하다. 본 연구에서는 대기 중에 존재하는 에어로졸을 실시간으로 농축하는 기술에 관한 것이다. (중략)

  • PDF

초정밀 스캐닝 스테이지를 위한 고분해능, 대변위의 MEMS 용량형 변위센서

  • Kim, Il-Hwan;Kim, Hyeon-Cheol;Jeon, Guk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.585-586
    • /
    • 2006
  • 본 논문에서는 MEMS 용량형 변위 센서의 제작과 함께, 미세 변위 측정을 위한 테스트 샘플을 제작하였다. 아래의 그림 1, 2는 각각 스테이지에 장착할 MEMS 용량형 변위 센서 및 미세 변위 측정을 위한 테스트 샘플의 개념도를 보여주고 있다. 테스트 샘플의 감지 부분은 스테이지에 장착할 센서와 정확히 일치를 시켰으며, 미세 변위를 주기 위해서 comb-drive actuator 형태의 운동부를 두었다. 운동부에서는 DC 및 AC 전압을 인가함으로써 미세 변위를 얻을 수 있었으며, 사용된 DC 전압은 20V였으며, 1.4kHz의 AC 전압을 크기를 변화시키며 인가하였다.

  • PDF

A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide (평행판 도파관을 이용한 유전율 측정 방법)

  • Cho, Gyo-Yeong;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.199-203
    • /
    • 2012
  • This paper introduces a simple new procedure approach to determine the permittivity of dielectric slabs. The method uses a parallel plate waveguide which supports a TEM mode. The presence of the dielectric slab placed at the bottom of the waveguide makes the speed of the TEM wave slower. The relationship between the change of the speed and the permittivity of the dielectric slab allows the determination of the permittivity. The relationship is analyzed electromagnetically, and the results of measurements are in good agreement with the analysis.

Measuring Vibration by using Line Scan Camera (라인 스캔 카메라를 이용한 진동 측정 기술)

  • Kim, Se-Oh;Jeon, Hyeong-Seop;Son, Ki-Sung;Park, Jong Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.751-752
    • /
    • 2014
  • 센서를 사용한 구조물의 진동측정 시 여러 문제로 인해 사용의 제약을 받아왔다. 이를 극복 하고자 최근 카메라를 이용한 진동 측정 기술이 연구되고 있지만 보통 산업용 카메라의 낮은 샘플링 주파수로 인해 구조물의 진동 측정에 한계를 보였다. 이러한 문제를 해결하기 위하여 본 연구에서는 라인 스캔 카메라의 높은 샘플링 주파수를 이용한 진동 측정 기술을 제안하고 실험을 통하여 성능검증을 수행하였다.

  • PDF