• Title/Summary/Keyword: 상태 감시

Search Result 1,088, Processing Time 0.027 seconds

COMS Electrical Power Subsystem Preliminary Design (통신해양기상위성 전력계 예비설계)

  • Gu, Ja-Chun;Kim, Ui-Chan
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.95-100
    • /
    • 2006
  • The COMS(Communication, Ocean and Meteorological Satellite) EPS(Electrical Power Subsystem) is derived from an enhanced Eurostar 3000 version. Eurostar 3000 EpS is fully autonomous operation in nominal conditions or in the event of a failure and provides a high level of reconfigure capability. This paper introduces the COMS EPS preliminary design result. COMS EPS consists of a battery, a solar arrat wing, a PSR(Power Supply Regulator), a PRU(Pyrotechnic Unit), a SDAM(Solar Array Drive Mechanism) and relay and fuse brackets. COMS EPS can offer a bus power capability of 3 kW. The solar array is made of a deployable wing with two panels. One type fo solar cells is selected ad GaAs/Ge triple junction cells. Li-ion battery is base lined with ten series cell module of five cells in parallel. PSR associated to battery and solar array wing generates a power bus fully regulated at 50 V. Power bus os centralized protection and distribution by relay and fuse brackets. PRU provides power for firing actuarors devices. The solar array wing is rotated by the SADM under control of the attitude orbit control subsystem. The control and monitoring of the EPS, especially of the battery, is performed by the PSR in combination with the on-board software.

  • PDF

The Development Trend of a VTOL MAV with a Ducted Propellant (덕티드 추진체를 사용한 수직 이·착륙 초소형 무인 항공기 개발 동향)

  • Kim, JinWan
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.68-73
    • /
    • 2020
  • This purpose of this paper was to review the development trend of the VTOL MAVs with a ducted propellant that can fly like the VTOL at intermediate and high speeds, hovering, landing, and lifting off vertically over urban areas, warships, bridges, and mountainous terrains. The MAV differs in flight characteristics from helicopters and fixed wings in many respects. In addition to enhancing thrust, the duct protects personnel from accidental contact with the spinning rotor. The purpose of the U.S. Army FCS and DARPA's OAV program is spurring development of a the VTOL ducted MAV. Today's MAVs are equipped with video/infrared cameras to hover-and-stare at enemies hidden behind forests and hills for approximately one hour surveillance and reconnaissance. Class-I is a VTOL ducted MAV developed in size and weight that individual soldiers can store in their backpacks. Class-II is the development of an organic VTOL ducted fan MAV with twice the operating time and a wider range of flight than Class-I. MAVs will need to develop to perch-and-stare technology for lengthy operation on the current hover-and-stare. The near future OAV's concept is to expand its mission capability and efficiency with a joint operation that automatically lifts-off, lands, refuels, and recharges on the vehicle's landing pad while the manned-unmanned ground vehicle is in operation. A ducted MAV needs the development of highly accurate relative position technology using low cost and small GPS for automatic lift-off and landing on the landing pad. There is also a need to develop a common command and control architecture that enables the cooperative operation of organisms between a VTOL ducted MAV and a manned-unmanned ground vehicle.

Agricultural drought monitoring using the satellite-based vegetation index (위성기반의 식생지수를 활용한 농업적 가뭄감시)

  • Baek, Seul-Gi;Jang, Ho-Won;Kim, Jong-Suk;Lee, Joo-Heon
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.4
    • /
    • pp.305-314
    • /
    • 2016
  • In this study, a quantitative assessment was carried out in order to identify the agricultural drought in time and space using the Terra MODIS remote sensing data for the agricultural drought. The Normalized Difference Vegetation Index (NDVI) and Enhanced Vegetation Index (EVI) were selected by MOD13A3 image which shows the changes in vegetation conditions. The land cover classification was made to show only vegetation excluding water and urbanized areas in order to collect the land information efficiently by Type1 of MCD12Q1 images. NDVI and EVI index calculated using land cover classification indicates the strong seasonal tendency. Therefore, standardized Vegetation Stress Index Anomaly (VSIA) of EVI were used to estimated the medium-scale regions in Korea during the extreme drought year 2001. In addition, the agricultural drought damages were investigated in the country's past, and it was calculated based on the Standardized Precipitation Index (SPI) using the data of the ground stations. The VSIA were compared with SPI based on historical drought in Korea and application for drought assessment was made by temporal and spatial correlation analysis to diagnose the properties of agricultural droughts in Korea.

바실러스에 의한 중금속 제거 및 EPS 추출물질 비교에 관한 연구

  • Son, Han-Hyeong;Kim, Pan-Su;Lee, Sang-Ho
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.05a
    • /
    • pp.423-427
    • /
    • 2006
  • 1) 바실러스는 불리한 환경조건에서 포자를 형성하며 포자는 균체가 죽어도 살아 남고, 외부 환경이 좋아지면 다시 발아하여 영양형 균체를 형성하게 된다. 본 연구에서 바실러스를 우점화와 포자의 활성화를 위해 열처리(80$^{\circ}C$, 10min)를 한다 울산분뇨처리장 슬러지 Cake를 배양하여 포자화 전 후 상태의 미생물의 EPS 추출결과 RCF법을 적용하였을 때 Carbohydrate물질이 다른 추출법에 비해 가장 많이 추출되었고, Steaming extraction법을 적용하였을 때 Protein이 가장 많이 추출되는 것으로 나타났으며, 포자화 전 보다 포자화 후의 EPS 양이 더 많이 추출될 것이라는 가설을 가지고 실험한 결과 포자화 전보다 포자화 후의 EPS 양이 더 많이 추출되었다. 울산분뇨처리장의 슬러지 Cake를 배양하여 포자화 전 후의 Cu의 제거정도를 비교한 결과 포자화 후의 EPS물질이 포자화 전의 EPS물질보다 Cu를 더 많이 제거하는 것으로 나타났으며 EPS 물질이 중금속 제거능력이 탁월하다고 할 수 있겠다. 2) 용인분뇨처리장과 천안하수처리장의 MLSS의 중금속 제거능력을 알아보기 위해 미생물량을 고려했을 경우와 미생물량을 고려하지 않은 경우로 나누어서 실험을 하였는데 울산분뇨처리장의 슬러지 Cake를 가지고 실험한 결과와 마찬가지로 Bacillus의 EPS물질이 중금속 제거에 탁월하다는 것을 알 수 있다. 3) Baillus를 사용하는 김천 식품폐수 처리장과 활성슬러지를 사용하는 천안하수처리장과의 EPS 함량을 비교한 결과 김천 식품폐수 처리장의 EPS 물질중 Protein과 Carbohydrate가 천안하수처리장의 활성슬러지보다 더 많은 것으로 나타났다.TEX>, DIN/DIP비 표층수 $23.91\pm3.42$, 저층수 $23.43\pm3.38$이었으며, 전반적으로 해역별 수질기준 I등급 내지는 II등급을 유지하고 있었고, 공간적으로는 외해측으로 갈수록 외해수와 혼합 확산되어 양호한 수질을 나타내었다. 장기적인 변동특성은 세그룹으로 구분되어진다.기 실험결과 용출용매로 증류수와 해수를 이용했을 때, 제강 슬래그에서 용출되는 납, 구리, 카드뮴, 수은의 용출 경향의 차이를 확인할 수 있었고 이에 따라서, 납, 구리, 카드뮴의 용출 유해성은 낮기 때문에 해양구조물로의 제강슬래그 유효이용은 적합할 것으로 판단되었다.im80%$로 계산되었다. 열형광선량계로 측정된 방사선량은 각각 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm 거리) cGy로 측정되었으며, 환자의 복부 표면에서의 서베이메터를 이용한 측정량은 10.9 mR/h였다. 차폐구조물의 사용 시 전체 치료 동안에 태아선량은 약 1 cGy 정도로 평가되었다. 결론 : AAPM Report No.50의 자료에 따르면, 임산부의 방사선 치료 시 태아의 방사선 피폭선량은 5 cGy 이하일 경우에 방사선 피폭에 따른 태아의 위험이 거의 없는 것으로 제시되고 있다. 본원에서 차폐 구조물을 설치하였을 경우에 측정된 태아선량은 약 1 cGy로 측정되었고, 고안된 차폐구조물은 태아에 도달하는 방사선량을 감소시키기에 적합한 설계임이 입증되었다. 아니라 일반종합병원에서도 CTX-M형 ESBL 생성 E. coli와 K. pneumoniae가 존재하며 확산 중임을 시사한다. 앞으로 CTX-M형 ESBL의 만연과 변종 CTX-M형 ESBL의 출연을 감시하기 위한 정기적인 연구와 조사가 필

  • PDF

Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station (발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2017
  • The only method used in the power stations in order to deliver generated electric power is 6 kV XLPE (or CV) single core cables. Among many kinds of accidents happening in the power stations, the outbreak of fire due to the deterioration of live cables causes enormous socioeconomic losses. From the installation of the cables, the management and diagnose should be thoroughly made. Even though it differs depending on the installations and usage conditions, the cross-sectional area of cables is in shortage. The excessive allowable temperature caused from the current causes the deterioration of cables. In order to prevent an unexpected breakdown of live cables, we have invented a device to monitor and diagnose the status of cables. We have installed our device in the Korea Western Power Co., Ltd.. In this paper, we present our research results in situ that we have obtained by measuring the temperature of sheath, changing with the surrounding circumstances, especially ambient temperatures. We also show our study results of characteristics for temperature of sheath surface and load current at the ambient temperatures of $40^{\circ}C-10^{\circ}C$.

Prevalence of Feline Panleukopenia Virus in Stray and Household Cats in Seoul, Korea (한국의 서울에 사는 길 고양이와 집 고양이에서 고양이 범백혈구감소증 바이러스의 유병률)

  • Kim, Seung-Gon;Lee, Kyo-Im;Kim, Ha-Jung;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.333-338
    • /
    • 2013
  • We investigated the prevalence of feline panleukopenia virus (FPV) in stray and household cats in different regions of Seoul, Republic of Korea. Blood samples were collected from a total of 200 cats (100 stray cats and 100 household cats) and examined by polymerase chain reaction (PCR). The overall prevalence of FPV was 2%. Among test-positive cats, 3% (3/100) were stray cats and 1% (1/100) was a household cat. The incidence of FPV was higher in juvenile cats (< 1 year, 1.5%) than in adult cats (> 1-year-old, 0.5%). The FPV-positive rates of healthy infected cats and sick cats were 1.9% (3/156) and 2.2% (1/44), respectively. We found the positive rate of vaccinated and unvaccinated cats to be 1.3% (1/77) and 2.4% (3/123), respectively. Unlike antibody tests, FPV antigen tests detected current infections in stray and household cats. Therefore, these tests can help in disease diagnosis and treatment. To our knowledge, our study is the first to survey the prevalence of FPV in different cat populations across Seoul. We found a high prevalence of FPV infection in stray and juvenile cats. Therefore, proper vaccination and surveillance are important to prevent FPV outbreaks.

Analysis of Packet Transmission Delay in the DC Power-Line Fault Management System using IEEE 802.15.4 (IEEE 802.15.4를 적용한 직류배전선로 장애관리시스템에서 패킷전송 지연시간 분석)

  • Song, Han-Chun;Hwang, Sung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.259-264
    • /
    • 2014
  • IEEE 802.15.4 has been emerging as the popular choice for various monitoring and control applications. In this paper, a fault management system for DC power-lines has been designed using IEEE 802.15.4, in order to monitor DC power-lines in real time, and to rapidly detect faults and shut off the line where such faults occur. Numbers were allocated for each node and unslotted CSMA-CA method of IEEE 802.15.4 was used, the performance of which was analyzed by a simulation. For such purpose, a total of 60 bits of the control data consisting of 16 bits of the current, 16 bits of the amplitude, 28 bits of the terminal state data were sent out, and the packet transfer rate and the transmission delay time of the fault management system for DC power-lines were measured and analyzed. When the traffic load was 330 packets per second or lower, the average delay time was shown to be shorter than 0.02 seconds, and when the traffic load was 260 packets per second or lower, the packet transfer rate was shown to be 99.99% or higher. Therefore, it was confirmed that the stringent condition of US Department of Energy (DOE) could be satisfied if the traffic load was 260 packets per second or lower, The results of this study can be utilized as basic data for the establishment of the fault management system for DC power-lines using IEEE 802.15.4.

DENTAL TREATMENT FOR A PATIENT WITH WILLIAMS SYNDROME UNDER GENERAL ANESTHESIA: CASE REPORT (윌리엄스 증후군(Williams syndrome) 환자의 전신마취 하 치과치료 : 증례보고)

  • Seo, Meekyung;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.14 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • Williams syndrome (WS) is a rare congenital disorder which is caused by microdeletion of approximately 1.6 MBP from the long arm of chromosome 7 at 7q11.23. It is characterized by cardiovascular anomalies, elfin face and mental retardation. The most typical oral signs in patient with WS are hypodontia, reduced mesio-distal dimensions both in the primary and permanent teeth, macroglossia, excessive interdental spacing, enamel hypoplasia and enamel hypomineralization. The majority of children with WS have mild to moderate mental retardation, generalized anxiety disorder, hyperactivity disorder and sensitivity to sounds. The purpose of this presentation is to describe dental treatment for a child with WS. A 9-year-old boy diagnosed with WS had caries on his first permanent molars. Because of the poor cooperation, these teeth were filled temporarily with glass ionomer, and treatment under general anesthesia was planned. Under general anesthesia, caries treatment of first permanent molar and extraction of primary molar was successfully performed and there was no postoperative complications related to general anesthesia. Open bite, hypodontia, excessive dental space, enamel hypoplasia, enamel hypomineralization were observed which were characteristic in WS.

Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System (U-헬스케어 시스템을 위한 개선된 PMAF 기반의 PPG 신호의 동잡음 제거)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Jun, Jae-Chul;Lee, Gun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.28-34
    • /
    • 2008
  • The real-time biomedical signal monitoring is a very important factor to realize the ubiquitous healthcare environment. Most of these devices for monitoring the biomedical information get the PPG signal from the user, and these signals are utilized for monitoring their health. It is inconvenient to get the PPG because the user should wear the finger probe with his finger for measuring the PPG signal. Also it is difficult to get the PPG correctly, because of the motion artifacts from the movement of the user. In this paper, we develop the watch type biomedical signal monitoring system without the finger probe, and propose the new algorithm for reducing the motion artifacts from the PPG signal. We designed the system which gets the PPG from the sensor on the wrist band strip. As compared with the finger probe type, this system we proposed is more affected by the motion artifacts. So to filter this motion artifacts, we propose the new method; the improved PMAF(Periodic Moving Average Filter) method.

A Study on Compressive Strength Estimation of Underwater Concrete Structures According to Water Depths (수중 콘크리트 구조물의 수심별 강도 추정에 관한 연구)

  • Lee, Jisung;Han, Sanghun;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.341-348
    • /
    • 2016
  • Harbor facilities require long-term durability and safety, and also maintain the performance requirement until the durability life. However, existing harbor facilities are becoming superannuated with durable years and durability is declined by erosion of the sea and damage from sea. In addition, harbor facilities will be in demand for the expansion of harbor and offshore structures with rising economic power by enhancement of domestic industry and increase of import and export. Therefore, in this study, two kinds of nondestructive test (NDT) techniques (schmidt rebound hammer and ultrasonic sensor) are verified for the effective maintenance of underwater concrete structures including harbor facilities. Sea field applicability of Schmidt hammer and ultrasonic sensor was verified by comparing field test result with sea field test result and also deduced the compressive strength estimation equation by depth of the water. On the basis of the sea field test result, compressive strength estimation equation which was deduced by multiple regression analysis indicated highest accuracy compared to other equations, especially it will be more likely to be used in underwater because of the depth of water correction. In the future, if schmidt hammer and ultrasonic sensor which were invented as waterproofing are used with ROV (Remotely Operated Vehicle), it will be possible to make a diagnosis of high reliability for underwater concrete structures and set up a ubiquitous concept of NDT system.