• Title/Summary/Keyword: 상태유지

Search Result 5,222, Processing Time 0.039 seconds

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Water Quality in a Drainage System Discharging Groundwater from Sangdae-ri Water Curtain Cultivation Area near Musimcheon Stream, Cheongju, Korea (무심천 인근 상대리 수막재배지에서 지하수 사용 후 배출되는 최종 배수로 물의 수질 특성)

  • Moon, Sang-Ho;Kim, Yongcheol;Hwang, Jeong
    • Economic and Environmental Geology
    • /
    • v.48 no.5
    • /
    • pp.409-420
    • /
    • 2015
  • The Sangdae-ri riverside around Musimcheon stream, flowing through Gadeok-myon of Cheongju City, is one of the representative strawberry fields employing water curtain cultivation (WCC) in Korea. In this area, annual groundwater use for WCC has been calculated by a few methods. On the assumption that all the water flowing through the final ditch may be mostly composed of groundwater, the discharge rate in it can be used as a good proxy for assessing the groundwater use. However, in the study area, the final ditch was set up in an unpaved state near and parallel to Musimcheon stream. Under such circumstances, the drainwater is likely to be influenced by infiltration and/or inflow of nearby stream. Hence, we examined whether or not stream water has influenced water flowing out through the final ditch in respect of ion concentrations or field parameters such as T, pH and electrical conductivity (EC) values. The period of measuring field parameters and sample collection was from February 2012 through February 2015. The drainwater in the final ditch did not show the average quality of groundwater, but similar quality of stream water in respect of pH, EC, ion contents and water type. From this, it is suggested that measuring the flow rate of the final ditch should not be directly used for assessing groundwater use in the study area. In addition, because of its sensitivity to ambient temperature, water temperature proved not to be appropriate for estimating the interaction between ditch and stream. For accuracy, additional methods will be needed to calculate mixing ratios between stream and ground water within drainage system.

Influence of Water Foxtail on Growth of Rice and Weed in No-Tillage Transplanted Rice (벼 무경운재배시 둑새풀 우점 정도가 벼 생육 및 잡초 발생에 미치는 영향)

  • 강양순;곽태순;송문태
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.5
    • /
    • pp.619-624
    • /
    • 1996
  • An experiment was carried out to find out the effects of water foxtail on weed control and rice yield as well as on the reduction of nitrogen application in no tillage transplanted paddy field. Paddy field was dominated by water foxtail whose soil covering degree was adjusted from 8 to 6 by treatment of paraquat (70 l /10a of solution diluted by 1, 000 times). Thirty five-day old seedling was mechanically transplanted and reduced nitrogen, 80% of conventional application was applied at the paddy field. The higher failure in seedling stand was observed at higher degree of soil covering by water foxtail. The failure of seedling stand with covering degree of 8(no paraquat) was 37.4%, while that of covering degree of 6(paraquat-treated) was 12.3%. However, the seedling stand failure was completely recovered at covering degree of six at two weeks after transplanting. The mechanical transplanting made water foxtail in the paddy field fall on the ground whose panicle part was recovered from falling sometimes after transplanting and whole plant died with slow scenesence untill the late of June. But the water foxtail affected by paraquat produced the new panicle from uppernode of stem with dead leaves at early of June and it become die slowly untill the early of July. Though several rice field weeds were observed in the order of Echinochloa crusgallis, Cyperus serotinus, Lemma paucicostata during the active tillering stage of rice, the value of weed control due to the dominance of water foxtail was 77~78%. The death and subsequent decay of water foxtail during the active tillering stage of rice induced the soil reduction which again defect the growth of rice root. The more vigerous rice growth was observed in the plot dominated with water foxtails, than control plot. The yields of rice in the water foxtail (degree 6) plot was 629kg per l0a as brown rice, the same as that of control plot. In conclusion, the no-tillage transplanting with control of covering degree of water foxtail (to degree 6) was effective in reduction of input cost such as herbicide and nitrogen fertilizer, as well as weed control without reduction of rice yield.

  • PDF

Change of Nutrients and Behaviour of Total Coliforms in the Natural Treatment of Wastewater by Subsurface Flow Wetland System (인공습지를 이용한 자연정화 오수처리시설에서 영양물질의 변화와 대장균군의 행동)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.249-254
    • /
    • 1997
  • The constructed wetland system which is applicable to rural wastewater treatment was examined by pilot plant experiment. Removal rates of nutrients including nitrogen and phosphorus and total coliform were evaluated. The $NH_4\;^+$ concentration of the influent was in the range of 91.57 to 275.88mg/l and the effluent concentration was about 40% lower than the influent. The decreasing of the $NH_4\;^+$ concentration might be due to volatilization, plant uptake, adsorption onto soil particles, and mainly nitrification. However, generally concentrations of $NO_2\;^-$ and $NO_3\;^-$ were increased in the effluents compared to the influent concentrations, which implies that nitrogen components in the system were nitrified. Overall, the average removal rate of the nitrogen was about 5% which seems inadequate as a wastewater treatment system, and this system needs improvement on nitrogen removal mechamism. The removal rate of the phosphorus was quite high and effluent concentration was very low. Reason for high removal rate of the phosphorus might be mainly strong adsorption characteristic onto soil particles. The average removal rate of the total coliforms was about 83%, and main removal mechanisms are thought to be adsorption onto soil and inability to compete against the established soil microflora. From the results of the study, the constructed wetland system needs to be improved in nitrogen removal mechanism for field application.

  • PDF

Surface Exchange of Energy and Carbon Dioxide between the Atmosphere and a Farmland in Haenam, Korea (한국 해남 농경지와 대기간의 에너지와 이산화탄소의 지표 교환)

  • Hee Choon Lee;Jinkyu Hong;Chun-Ho Cho;Byoung-Cheol Choi;Sung-Nam Oh;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.61-69
    • /
    • 2003
  • Surface energy and $CO_2$ fluxes have been measured over a farmland in Haenam, Korea since July 2002. Eddy covariance technique, which is the only direct flux measurement method, was employed to quantitatively understand the interaction between the farmland ecosystem and the atmospheric boundary layer. Maintenance of eddy covariance system was the main concern during the early stage of measurement to minimize gaps and uncertainties in the dataset. Half-hourly averaged $CO_2$ concentration showed distinct diurnal and seasonal variations, which were closely related to changes in net ecosystem exchange (NEE) of $CO_2$. Daytime maximum $CO_2$ uptake was about -1.0 mg $CO_2$ m$^{-2}$ s$^{-1}$ in August whereas nighttime $CO_2$ release was up to 0.3 mg $CO_2$ m$^{-2}$ s$^{-1}$ during the summer. Both daytime $CO_2$ uptake and nighttime release decreased gradually with season. During the winter season, NEE was from near zero to 0.05 mg $CO_2$ m$^{-2}$ s$^{-1}$ . FK site was a moderate sink of atmospheric $CO_2$ until September with daily NEE of 22 g $CO_2$ m$^{-2}$ d$^{-1}$ . In October, it became a weak source of $CO_2$ with an emission rate of 2 g $CO_2$ m$^{-2}$ d$^{-1}$ . Long-term flux measurements will continue at FK site to further investigate inter-annual variability in NEE. to better understand these exchange mechanism and in-depth analysis, process-level field experiments and intensive short-term intercomparisons are also expected to be followed.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES (Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향)

  • Yang, Kyung-Ran;Jung, Oh-Chul;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.131-143
    • /
    • 1994
  • For maintenance of exposed implant in healthy state, it is necessary to treat the surface of implant fixture and provide the surface adjustable to surrounding tissues. Variable techniques have been introduced such as citric acid and air-abrasive system to treat the failed implant. Although when the rough surface of HA coated implant was exposed to oral environment, the surface treatment method with citric acid or air-abrasive system is effective for removal of bacterial endotoxin, it is unsuccessful to prevent plaque deposition due to difficulty in removal of rough surface of HA coated implant. Thus, in this study the method that removes bacterial endotoxin and makes smooch surface without alteration of surface characteristics was studied. HA coated disc manufactured by IMZ Co. Was treated with high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher. And then its surface state was examined with profilometer and SEM to evaluate the surface smoothness, and its surface component was analyzed with EDX to evaluate wheter the surface characteristics were altered or not. As a result, following results were obtained. When the surface roughness of each implant disc was measured by profilometer, the group I showed a $R_{max}\;2.11{\mu}m$ and the group II, III, IV, V showed a $R_{max2}\;4.17{\mu}m$, $7.28{\mu}m$, $8.61{\mu}m$ and $39.44{\mu}m$ respectively. That is, surface smoothness was highest in the group I and it has been gradually decreased in the group II, III, IV and V. Under the SEM examination, the group I showed relatively smooth surface and the group II showed slightly rougher surface than the group I due to partially remaining HA particles while most HA particle was removed. The group III and IV showed rough topography due to HA particles that was not grinded, and HA coated surface in group V showed very irregular surface with deep groove and prominence. In cross-sectional view, the group I showed uniform surface, and the group III, IV showed rough surface due to remaining HA particles but the thickness of HA coating was remarkably reduced. The group II has similar pattern in group I, and the group V showed about $40{\mu}m$ thickness although it was not constant. By analysis of surface component with EDX, the group II in which the grinding was effective showed a small quantity of calcium and phosphorous and the group III, IV, in which the grinding was incomplete showed calcium and phosphorus peak. In all experimental group, no other than titanium, aluminum, calcium, phosphorus was observed.

  • PDF

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

A Clinical Study of Hearing Disturbance and Middle Ear Pathology in Chronic Otitis Media (만성중이염의 교실내 병변과 청력에 관한 임상적 연구)

  • 박동석;전재기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.4.4-5
    • /
    • 1979
  • The degree of hearing impairment of chronic otitis media will indicate the nature and severity of middle ear pathology especially condition of ossicular chain, size of ear drum perforation and location of granulation tissue in the middle ear cavity. The subjects were 189 ears of tympanoplasty for chronic otitis media and divided into four groups as follows: Normal ossicular chain with only ear drum perforation (group I), normal ossicular chain with granulation tissue only around the ossicles regardless of any other region (group II), ossicular ankylosis or fixation of handle of malleus to promontory with or without granulation tissue around the ossicle (group III) and ossicular interruption by partial or complete destruction(groupf IV). The results were concluded as follows: 1) The average hearing threshold of chronic otitis media was 44.6 dB and hearing threshold was closely related to the condition of ossicular chain. Hearing threshold became greater in order of normal ossicular chain, ankylosis and interruption. 2) The average hearing threshold of ossicular interrupted group was 49.1 dB and it was greater in the cases of total destruction than that of partial destruction. 3) The hearing loss in the cases of normal ossicular chain with only tympanic membrane perforation was within 45 dB and this level was presumed to represent normal ossicular function. The degree of hearing loss was in proportion to the size of ear drum perforation and when over 45 dB, other middle ear pathology was suggested. 4) In the cases of small ear drum perforation with normal ossicular function, the hearing threshold was within 30 dB. 5) In the type of audiogram, flat type was 30.2% and ascending type 35.4%. Descending type was more frequent in the cases of normal ossicular mobility with granulation tissue around the ossicle and flat type was observed frequently in the cases of ossicular ankylosis. 6) Carhart's notch was seen in 14 cases (7.4%) and observed mainly in ossicular ankylosis. 7) There was no relation between hearing threshold and histopathological type of granulation tissue in chronic otitis media. However the degree of hearing impairment was related to the location of granulation tissue in the middle ear cavity. 8) Authors recognized the granulation tissue compensated the function of interrupted ossicular chain.

  • PDF

A Study on the Actual Conditions of Denture Prosthodontics used by the Elderly Aged 65 or Older in Seoul (시술장소에 따른 65세 이상 노인의 의치보철 실태 조사연구)

  • Jung, Jung-Ock
    • Journal of dental hygiene science
    • /
    • v.7 no.3
    • /
    • pp.113-119
    • /
    • 2007
  • This study attempts to find factors contributing to the use pattern of prosthetics by investigating the current condition of prosthetics for the aged of over 65 years old by place of practice. Among those of over 65 years old who live in Gangnam-gu, Seocho-gu, Seongbuk-gu, and Gwanak-gu of Seoul and use the apartment senior's center, those having prosthetics were selected as subjects of this study, and this study was conducted in forms of interview and record. Findings of this study are summarized as follows: First, in regard of the state of prosthetics and relevant symptoms in the mouth according to the place of prosthetics practice, there was significant difference in the questions except the medical benefit of prosthetics between unlicensed facilities and dental clinics and hospitals. Second, regarding difference in satisfaction according to the place of prosthetics practice, dental clinics and hospitals showed a higher level of aesthetic satisfaction than unlicensed facilities. For difference in satisfaction at pronunciation, chewing, pain, a sense of foreign body, and holding power, dental clinics and hospitals showed a higher level than unlicensed facilities, Third, after factor analysis on the perception factors of unlicensed treatment and dental treatment, unlicensed facilities showed the highest level of reliability, and then convenience, word of mouth, and modernity in order. Dental clinics and hospitals also showed the highest level of reliability, however, and then convenience, modernity, and word of mouth in order. Fourth, as a consequence of analyzing the factors to influence the use pattern of prosthetics, regarding residential pattern, there were higher possibilities to use dental clinics and hospitals when the subjects lived together with their children and in Gangnam, and the more were the number of pyeong for the residence, pocket money, medical expense, and property in their name, compared to unlicensed facilities. In conclusion, economic factors appear to be the most important factors in selecting facilities for denture prosthodontics. Therefore, it is important to ensure the denture prosthodontics for the elderly are reimbursable so that they can enjoy a healthier life.

  • PDF