• Title/Summary/Keyword: 상용카메라

Search Result 98, Processing Time 0.029 seconds

Development of DirectX-based Stereoscopic Image Authoring Tool for Immersive e-Book Production (몰입형 e-Book 제작을 위한 DirectX기반 입체 영상 저작도구 개발)

  • Lee, Keunhyung;Park, Jinwoo;Kim, Jinmo
    • Journal of Digital Contents Society
    • /
    • v.17 no.1
    • /
    • pp.23-31
    • /
    • 2016
  • This study aims to develop a stereoscopic image authoring tool to effectively produce e-Book content that enhances user's sense of immersion in 3D environments. The proposed authoring tool consists of three core systems; 3D object editing, stereoscopic image, and image media production systems. First, the object editing system arranges and produces diverse objects that constitute virtual 3D spaces to fit the purpose of the content. In this case, commercial graphic authoring tools are utilized to design efficient data structures that can include produced external models. In addition, the material and textures of objects are made to be revisable and editable into the form wanted by the user. Thereafter, a stereoscopic image system will be implemented to produce the generated virtual scenes into stereoscopic images. This study uses the Anaglyph method so that the user can implement and use stereoscopic image scenes more easily. This method include functions to change the color of stereo cameras and control depth scaling. Finally, an image media production system will be implemented that will enable producing the produced stereoscopic images into single images or videos so that they can be effectively utilized in e-Book content.

A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature (용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구)

  • Kim, Yong-il;Park, Byung Gi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.165-172
    • /
    • 2018
  • As an approach for estimation of the droplet size in the molten salt-liquid metal extraction process, a droplet formation experiment at room temperature was conducted to evaluate the applicability of the Scheele-Meister model with water-mercury system as a surrogate that is similar to the molten salt-liquid metal system. In the experiment, droplets were formed through the nozzle and the droplet size was measured using a digital camera and image analysis software. As nozzles, commercially available needles with inner diameters (ID) of 0.018 cm and 0.025 cm and self-fabricated nozzles with 3-holes (ID: 0.0135 cm), 4-holes (ID: 0.0135 cm), and 2-holes (ID: 0.0148 cm) were used. The mercury penetration lengths in the nozzles were 1.3 cm for the needles and 0.5 cm for the self-fabricated nozzles. The droplets formed from each nozzle maintained stable spherical shape up to 20 cm below the nozzle. The droplet size measurements were within a 10% error range when compared to the Scheele-Meister model estimates. The experimental results show that the Scheele-Meister model for droplet size estimation can be applied to nozzles that stably form droplets in a water-mercury system.

A Indoor Management System using Raspberry Pi (라즈베리 파이를 이용한 실내관리 시스템)

  • Jeong, Soo;Lee, Jong Jin;Jung, Won Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • In the era of the Internet of Things, where all physical objects are connected to the Internet, we suggest a remote control system using a Raspberry Pi single-board computer with ZigBee, which can turn an indoor light-emitting diode (LED) and a multiple-tap on and off, and with a smart phone can control the brightness of the LED as well as an electronic door lock. By connecting an infrared (IR) transmitter module to the Raspberry Pi, we can control home appliances, such as an air conditioner, and we can also monitor indoor images, indoor temperatures, and illumination by using a smart phone app. We developed a method of finding out IR transmission codes required for remote-controllable appliances with an AVR micro-controller. We suggest a method to remotely open and shut an office door by novating the door lock. The brightness level of an LED (between 0 and 10) can be controlled through a PWM signal generated by an ATmega88 microcontroller. A mutiple-tap is controlled using an ATmega32, a photo-coupler, and a TRIAC. The signals for measured temperature and illumination are converted from analog to digital by using the ATtiny44A microcontroller transmitting to a Raspberry Pi through SPI communication. Then, we connect a camera to the CSI head of the Raspberry Pi. We can turn on the smart multiple-tap for a certain period of time, or we can schedule the multi-tap to turn on at a specific time. To reduce standby power, people usually pull out a power code from multiple-taps or turn off a switch. Our method helps people do the same thing with a smart phone, if they are away from home.

Building Large-scale CityGML Feature for Digital 3D Infrastructure (디지털 3D 인프라 구축을 위한 대규모 CityGML 객체 생성 방법)

  • Jang, Hanme;Kim, HyunJun;Kang, HyeYoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.187-201
    • /
    • 2021
  • Recently, the demand for a 3D urban spatial information infrastructure for storing, operating, and analyzing a large number of digital data produced in cities is increasing. CityGML is a 3D spatial information data standard of OGC (Open Geospatial Consortium), which has strengths in the exchange and attribute expression of city data. Cases of constructing 3D urban spatial data in CityGML format has emerged on several cities such as Singapore and New York. However, the current ecosystem for the creation and editing of CityGML data is limited in constructing CityGML data on a large scale because of lack of completeness compared to commercial programs used to construct 3D data such as sketchup or 3d max. Therefore, in this study, a method of constructing CityGML data is proposed using commercial 3D mesh data and 2D polygons that are rapidly and automatically produced through aerial LiDAR (Light Detection and Ranging) or RGB (Red Green Blue) cameras. During the data construction process, the original 3D mesh data was geometrically transformed so that each object could be expressed in various CityGML LoD (Levels of Detail), and attribute information extracted from the 2D spatial information data was used as a supplement to increase the utilization as spatial information. The 3D city features produced in this study are CityGML building, bridge, cityFurniture, road, and tunnel. Data conversion for each feature and property construction method were presented, and visualization and validation were conducted.

New Synthesis of Sestamibi and Comparison of Stability of Its Formulation (Sestamibi의 신규합성과 제제화에 따른 안정성 비교)

  • Son, Mi-Won;Lim, Joong-In;Chang, Young-Soo;Jung, Mi-Young;Jeong, Lak-Shin;Kim, Soon-Hoe;Kim, Won-Bae;Jeong, Jae-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.5
    • /
    • pp.334-341
    • /
    • 2001
  • Purpose: Ascorbic acid us known to act as an antioxidant. Therefore, it can be used in increasing the efficiency of radiochemical labeling of Technetium-99m setamibi by inhibition of oxidation of $Sn^{2+}$ at low concentration. We intended to estimate the efficiency of radiochemical labeling and the stability of the newly formed formulation when ascorbic acid was added to a commercial kit. Materials and Methods: Synthesis of sestamibi was performed according to Dong-A's patent procedure (No.10-2001-0012877). First, we undertook a study to evaluate the efficiency of radiochemical labeling of sestamibi containing ascorbic acid. The stability of the vials was assessed using either $7.5{\mu}g\;or\;75{\mu}g$ of ascorbic acid, added to commercial vials under the accelerated condition(Temp : $40^{\circ}C{\pm}2^{\circ}C$, Relative humidity : $75{\pm}5%$). Results: Sestamibi was synthesized in overall 35-40% yield over 5 steps from a commercially available methallyl chloride as a starling material. When ascorbic acid was added, the efficiency of radiochemical labeling was maintained compared to the vial with no ascorbic acid. The accelerated test showed that the addition of ascorbic acid inhibited the oxidation of $Sn^{2+}$ ion by antioxidation mechanism. Also, the efficiency of radiochemical labeling of this vial after 9 months was nearly the same as the starting point. Therefore, the storage period of the kit is likely to be extended. Taken together, it suggests that the addition of ascorbic acid as a stabilizer is desirable. Conclusion: To increase the stability of a sestamibi cold kit, it is desirable to add ascorbic acid as a stabilizer to the commercial formulation.

  • PDF

A Study on effective directive technique of 3D animation in Virtual Reality -Focus on Interactive short using 3D Animation making of Unreal Engine- (가상현실에서 효과적인 3차원 영상 연출을 위한 연구 -언리얼 엔진의 영상 제작을 이용한 인터렉티브 쇼트 중심으로-)

  • Lee, Jun-soo
    • Cartoon and Animation Studies
    • /
    • s.47
    • /
    • pp.1-29
    • /
    • 2017
  • 360-degree virtual reality has been a technology that has been available for a long time and has been actively promoted worldwide in recent years due to development of devices such as HMD (Head Mounted Display) and development of hardware for controlling and executing images of virtual reality. The production of the 360 degree VR requires a different mode of production than the traditional video production, and the matters to be considered for the user have begun to appear. Since the virtual reality image is aimed at a platform that requires enthusiasm, presence and interaction, it is necessary to have a suitable cinematography. In VR, users can freely enjoy the world created by the director and have the advantage of being able to concentrate on his interests during playing the image. However, the director had to develope and install the device what the observer could concentrate on the narrative progression and images to be delivered. Among the various methods of transmitting images, the director can use the composition of the short. In this paper, we will study how to effectively apply the technique of directing through the composition of this shot to 360 degrees virtual reality. Currently, there are no killer contents that are still dominant in the world, including inside and outside the country. In this situation, the potential of virtual reality is recognized and various images are produced. So the way of production follows the traditional image production method, and the shot composition is the same. However, in the 360 degree virtual reality, the use of the long take or blocking technique of the conventional third person view point is used as the main production configuration, and the limit of the short configuration is felt. In addition, while the viewer can interactively view the 360-degree screen using the HMD tracking, the configuration of the shot and the connection of the shot are absolutely dependent on the director like the existing cinematography. In this study, I tried to study whether the viewer can freely change the cinematography such as the composition of the shot at a user's desired time using the feature of interaction of the VR image. To do this, 3D animation was created using a game tool called Unreal Engine to construct an interactive image. Using visual scripting of Unreal Engine called blueprint, we create a device that distinguishes the true and false condition of a condition with a trigger node, which makes a variety of shorts. Through this, various direction techniques are developed and related research is expected, and it is expected to help the development of 360 degree VR image.

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.