• Title/Summary/Keyword: 상승형

Search Result 1,318, Processing Time 0.035 seconds

A Study on the Climb Flight Test of Light Airplane (경비행기의 상승 비행시험에 대한 연구)

  • Lee, Jung-Hoon;Choi, Byung-Chul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.308-315
    • /
    • 2007
  • This study is performed to find out the climb performance of light airplane, Chang Gong-91, as a part of flight test to acquire the certification. Chang Gong-91 is a 5-passenger light aircraft of normal category with single reciprocating engine, and the first officially certified by Korean Ministry of Construction and Transportation in 1993. These flight test procedure and data for climb performance are used to get type certification. We have got maximum climb rate for operating altitude, best angle of climb speed, best rate of climb speed, and absolute ceiling of Chang Gong-91 using drag polar data reduction method from sawtooth climb flight data. Also we compare the form drag coefficient from the results of climb performance and Oswald's effectiveness coefficient to design values using lift-drag curve of light airplane.

Adaptive Lock Escalation in Database Management Systems (데이타베이스 관리 시스템에서의 적응형 로크 상승)

  • Chang, Ji-Woong;Lee, Young-Koo;Whang, Kyu-Young;Yang, Jae-Heon
    • Journal of KIISE:Databases
    • /
    • v.28 no.4
    • /
    • pp.742-757
    • /
    • 2001
  • Since database management systems(DBMSS) have limited lock resources, transactions requesting locks beyond the limit mutt be aborted. In the worst carte, if such transactions are aborted repeatedly, the DBMS can become paralyzed, i.e., transaction execute but cannot commit. Lock escalation is considered a solution to this problem. However, existing lock escalation methods do not provide a complete solution. In this paper, we prognose a new lock escalation method, adaptive lock escalation, that selves most of the problems. First, we propose a general model for lock escalation and present the concept of the unescalatable look, which is the major cause making the transactions to abort. Second, we propose the notions of semi lock escalation, lock blocking, and selective relief as the mechanisms to control the number of unescalatable locks. We then propose the adaptive lock escalation method using these notions. Adaptive lock escalation reduces needless aborts and guarantees that the DBMS is not paralyzed under excessive lock requests. It also allows graceful degradation of performance under those circumstances. Third, through extensive simulation, we show that adaptive lock escalation outperforms existing lock escalation methods. The results show that, compared to the existing methods, adaptive lock escalation reduces the number of aborts and the average response time, and increases the throughput to a great extent. Especially, it is shown that the number of concurrent transactions can be increased more than 16 ~256 fold. The contribution of this paper is significant in that it has formally analysed the role of lock escalation in lock resource management and identified the detailed underlying mechanisms. Existing lock escalation methods rely on users or system administrator to handle the problems of excessive lock requests. In contrast, adaptive lock escalation releases the users of this responsibility by providing graceful degradation and preventing system paralysis through automatic control of unescalatable locks Thus adaptive lock escalation can contribute to developing self-tuning: DBMSS that draw a lot of attention these days.

  • PDF

Study on the Prestressing Effect of 3 Span Continuous Preflex Composite Beam of Bridges by Re-Up Down of Supports (지점 재 상승·하강에 의한 3경간 연속 프리플렉스 합성형의 프리스트레싱 효과에 관한 연구)

  • Koo, Min Se;Park, Young Je;Kim, Phil Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.433-441
    • /
    • 2001
  • Thus study presents the basic concepts of 3 span continuous preflex composite beam of bridges by re-up down of supports and analysis relationship of between variables and stress of critical section. Also, it shows the pre-compression effects of re-up down of supports method by presenting the difference of between old section and new section got from new method. This study's new method makes more economic sections to be possible and when the sections designed with the existing method are used in the new method. efficient stress state is accomplished.

  • PDF

Fireproof Performance of Mortar using Gypsum in Simplified Heating Test (간이 내화시험에 의한 석고계 모르타르의 내화성능)

  • Kang, Suk-Pyo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.181-188
    • /
    • 2011
  • Spalling must be considered when designing high-strength concrete to cope with fire. This study investigates the temperature rise of steel bar in high-strength concrete coated with fireproof mortar using gypsum exposed to fire. It was found that fireproof mortar using gypsum is more effective in constraining the temperature rise of steel bar in the high strength concrete than fireproof mortar using cement, and that the thinner the cover depth of the fireproof mortar, the more significant the influence of the gypsum. In addition, while there was no difference between ${\alpha}$-hemihydrate mortar and ${\beta}$-hemihydrate mortar on the temperature rise of steel bar, the compressive strength of ${\alpha}$-hemihydrate mortar is higher than that of ${\beta}$-hemihydrate mortar.

Research on Comparison of Individual and Connecting Grounding Electrode for Potential Rise Distribution (개별 접지전극과 연접된 접지전극의 전위상승 분포 비교 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • This paper deals with a comparison of individual and connecting grounding electrode for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. In order to analyze the potential rise of grounding systems, a hemispherical water tank experimental apparatus was studied. Potential rise was measured and analyzed regarding the grounding method and distance by using this apparatus. The apparatus was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by the horizontal moving probe of the potentiometer. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding electrode were higher than those of connecting grounding electrode. The distributions of surface potential are dependent on the distance from grounding electrode.

Improving Interactivity via Chained Priority Boosting for Android Smartphone (연쇄적 우선순위 상승 기법에 의한 안드로이드 스마트폰의 사용자 반응성 향상)

  • Lee, Joonghyun;Huh, Sungju;Hong, Seongsoo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.01a
    • /
    • pp.1-2
    • /
    • 2013
  • 본 논문에서는 안드로이드의 고질적인 문제점인 사용자 반응성 문제 해결을 위한 연구를 소개한다. 특히 여러 응용들이 동시에 수행되는 경우 대화형 응용이 다른 응용들에 밀려 원하는 만큼 CPU를 얻지 못하는 상황에서 발생하는 반응지연 문제에 초점을 맞추고 이를 극복하기 위한 연쇄적 우선순위 상승 기법을 제시한다. 이 기법은 대화형 웅용뿐만 아니라 기존 연구에서 고려하지 않은 터치 관련 이벤트 처리 스레드들과 대화형 응용의 자식 스레드들의 우선순위를 연쇄적으로 상향시킴으로써 터치에 대한 응답시간을 줄인다. 본 논문에서는 제안한 기법을 상용 스마트폰에 적용하여 유용성을 검증하였다. 실험 결과에 따르면 기존 안드로이드에 제안한 기법을 적용한 경우 평균반응시간이 기존의 31.91%로 감소하였다.

  • PDF

Statistic Evaluation of Changing Pattern of Blood Pressure and Pulse Rate During Enflurane Anesthesia (Enflurane 마취시 혈압 및 맥박의 변화상에 대한 통계학적 관찰)

  • Suh, Ill-Sock;Park, Dae-Pal
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.81-85
    • /
    • 1986
  • Observation of changing pattern of blood pressure and pulse rate of enflurane anesthesia for 200 cases operations, performed during the past 4 years(1983~1986) in Yeungnam University Hospital have been evaluated clinically. In order to observe the influence of enflurane upon the blood pressure and pulse rate during general anesthesia, the authors prepared a formula, expressing changing of blood pressure and pulse rate by time series and analyzed the types and distribution pattern in the experiment. The results obtained were as follows : 1. Blood pressure and pulse rate were increased at the time of intubation. 2. Generally, blood pressure and pulse rate were increased at the time of intubation and then stabilized withing 20 minutes. 3. Most common patterns were identified, ADEE type was 73~74%, Which is most common type and AEEE type was about 40%.

  • PDF

Temperature Properties about SMD Inductor Core of Union Type (일체형 SMD Inductor 코어에 대한 온도 특성)

  • Kim, Ki-Joon
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.32-37
    • /
    • 2010
  • In this study, to develop union type SMD inductor core needs to have the desire of super miniaturization and high reliability, it analyzed temperature properties due to electric power value. As the temperature of electronic parts rise, it bring to technical obstacles that parts can not normal operation, it reduce the span of life to raise the fault ratio. Also, it impact to the parts by heat change power and expansive power, it can not behave exactly, and it have an effect on reliability. It measured the difference value between conditional temperature and parts temperature to union type SMD inductor core. As the results of simulation using D.C. current and resistor($R_dc$), it obtained the excellent regular current values at rising temperature of 40[$^{\circ}C$].

Failure Mode of 3 Phase VSI by using Average Method of Power Loss (전력 손실 평균화 기법에 의한 3상 전압형 인버터의 소손 모드에 관한 연구)

  • Cho, Su-Eog
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.199-201
    • /
    • 2007
  • 본 논문에서는 저가의 3상 전압형 인버터를 개발하기 위하여, 시스템에 최적화된 전력 변환 장치로 설계하고 이 때 산업 사회에서 요구하는 수명을 만족하기위해 실시간으로 전력 손실을 감시하여 전력 반도체의 수명을 보장하고, 소손 시 분석을 용이하게 하기위하여 소손 모드를 패턴 화 하였다. 전력반도체 열 손실의 이상 유무를 평균 전류 혹은 평균 손실을 이용하여 계산된 온도 상승 기울기와 방열판에서 실측된 온도 상승 기울기와 비교하여 일정 범위 내에 존재함을 확인함으로서 그 가능성을 실험을 통하여 확인하였다.

  • PDF

Expert System for Predicting the Stock Market Timing Using Candlesticks Chart (캔들스틱 차트 분석을 이용한 주식 매매 타이밍 예측을 위한 전문가 시스템)

  • 이강희;양인실;조근식
    • Journal of Intelligence and Information Systems
    • /
    • v.3 no.2
    • /
    • pp.57-70
    • /
    • 1997
  • 주식 시장을 예측하는 문제는 금융 분야에서 중요한 관심이 되어왔다. 주식 시세는 시장 환경의 변화에 따라 급격한 변화를 갖는다. 따라서 주식 투자로부터 이윤을 창출하기 위해서 주식을 사고 파는 시점을 결정하는 문제는 중요하다. 본 연구에서는 주시 매매 타이밍을 예측하기 위해서 캔들스틱 차트(Candlesticks chart)분석을 이용한 전문가 시스템(Expert System)으로서 '차트 해석기 (Chart Interpreter)'를 설계, 개발하였다. 주식 가격의 변동을 예고하는 패턴들을 정의하고 그 패턴들의 의미에 따라 매미결정을 첨가한 규칙을 생성하였다. 정의된 패턴들은 의미에 따라 크게 하락형, 상승형, 중립형, 추세지속형, 추세 전환형으로 분류된다. 정의된 패턴과 지식베이스의 유용성을 검증하기 위해서 수행된 1992년부터 1997년에 걸친 과거 한국 주식 시장 실거래 투자 데이터에 대한 실험결과는 평균 투자 성공률이 약 72%로서 주식시장에서 투자자들의 투자를 돕는데 우수한 지표로서 사용될 수 있음을 보였다. 또한, 개발된 지식베이스는 특정 연도나 특정 분야에 따라 예측력이 크게 변하지 않은 시간 독립적이고 분야 독립적인 특성을 가짐으로 분야나 시간에 구애받지 않고 사용할 수 있다는 장점을 갖는다.

  • PDF