• Title/Summary/Keyword: 상수도 관망운영

Search Result 75, Processing Time 0.036 seconds

Two-dimensional unsteady flow analysis with a five region turbulence models for a simple pipeline system (단순한 관망체계에서 5영역 난류 모형을 이용한 2차원 부정류 흐름 해석 연구)

  • Kim, Hyun Jun;Kim, Sangh Hyun;Baek, Da Won
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.971-976
    • /
    • 2018
  • An accurate analysis of pipeline transient is important for proper management and operation of a water distribution systems. The computational accuracy and its cost are two distinct components for unsteady flow analysis model, which can be strength and weakness of three-dimensional model and one-dimensional model, respectively. In this study, we used two-dimensional unsteady flow model with Five-Region Turbulence model (FRTM) with the implementation of interaction between liquid and air Since FRTM has an empirical component to be determined, we explored the response feature of two-dimensional flow model. The relationship between friction behaviour and the variation of undetermined parameter was configured through the comparison between numerical simulations and experimental results.

A study on the use of fire hydrants as a heat wave reduction facility through hydraulic analysis of water supply network (상수관망 수리해석을 통한 폭염 저감 시설로써의 소화전 활용방안연구)

  • Hong, Sung Jin;Choi, Doo Yong;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1215-1222
    • /
    • 2021
  • In this study, a study on how to use a fire hydrant as a heat wave reduction facility through hydraulic analysis of the water supply pipe network was conducted. Assuming that the fire hydrant installation point is open for heat wave reduction, the water pressure at each point was derived. And the reduction rate of the temperature according to the hydrant watering was compared with the watering area according to the operation of the watering truck. The watering area according to the opening of the fire hydrant was calculated by deriving the pressure value at the node where the fire hydrant was installed through hydraulic analysis of the water pipe network, and then using the watering radius relational expression according to the pressure value. As a result of applying the proposed methodology to two real city areas, the temperature reduction effect of the watering method by a fire hydrant can be derived lower than the watering method by a watering truck according to the difference in the absolute watering area. However, unlike a watering truck, a fire hydrant does not have a relative restriction on the amount of water supply and is expected to allows continuous divided spraying of the same area.

Development of an Algorithm for Intellectual Control System of Desalination Plants (해수담수화시설의 지능적 운영을 위한 알고리즘 개발)

  • Park, Hyunki;Lee, Dongseop;Han, Kukheon;Kim, Jaeho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.522-522
    • /
    • 2016
  • 우리나라의 488개 유인도 중 강수량 부족 혹은 지하수의 수질문제 등으로 상습적 식수난을 겪고 있는 도서지역은 237개에 이르고 있다. 이들 도서지역은 생활용수를 우물, 간이상수도, 운반급수 등에 의존하고 있지만 이중 47%의 도서는 간이급수시설이 전무한 실정이다. 2015년에는 인천시 옹진군의 소청도, 대청도에 장기간 지속된 가뭄으로 식수원이 고갈되어 3일에 1시간으로 급수를 제한하였고 이로 인해 식수난 문제 외 관광산업의 소득저하 등의 문제가 발생되어 원활한 물공급문제가 해결되지 않으면 도서지역의 위기는 심각할 것으로 우려된다. 도서지역의 기본권인 먹는 물 문제를 해결하기 위해 정부 및 지자체에서는 소규모 유인도서에 해수담수화시설을 설치하여 유지관리 및 운영을 위한 인력을 배치하고 수동으로 조작하거나 단순 자동운전에 의해 운영 및 관리되고 있는 실정이다. 본 연구에서는 해수담수화시설의 안정적이고 효율적인 운영을 위해 지능적 수운영 알고리즘을 개발하였다. 제어시스템, 감시시스템, 계측시스템 등의 ICT 기술과 연계하여 수요를 정확히 예측하고, 실시간 전력비용과 저류량, 사용량 등을 통합적으로 고려하였으며 적시정량을 생산하여 저장 및 공급하며, 목표수질과 수량을 원활하고 안정적으로 공급할 수 있도록 제어 및 감시를 통한 지능적 수운영을 목적으로 연구하였다. 데이터의 수집과 전송, 분석, 제어, 감시 활동이 유기적으로 결합되어 용수의 생산과 분배, 공급활동을 자동화함으로 운영상의 리스크를 줄여주며, 필요시 통합운영센터에서의 의사결정을 지원할 수 있도록 개발하였다. 향후, 해수담수화시설뿐이 아닌 일반 상수도 수운영에 있어서의 취수, 도수, 정수, 배수지관리, 송수, 관망관리까지 자동화된 시스템을 개발하여 지능적 운영관리가 가능하도록 알고리즘 모델 및 프로그램을 제시하고자 한다.

  • PDF

Analysis of water quality smart meter data using dynamic time warping (Dynamic Time Warping을 이용한 수질 스마트미터 데이터 분석)

  • Lim, Soyeon;Jung, Donghwi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.173-173
    • /
    • 2021
  • 현재까지 상수도관망 내 수질적 거동에 대한 분석은 (1) 네트워크 수질 모델(EPANET 수질모의 등)에 기반한 방법과 (2) 시공간적 저해상도 데이터에 기반한 데이터 분석법이 주를 이루었다. 그러나 현존 네트워크 수질 모델은 수질 사고의 복잡한 물리·화학적 거동을 상세히 모의하기 어렵다. 반면 계측 및 통신기술의 발달로 고해상도 수질 데이터의 실시간 수집이 가능해지면서 사고의 사전감지, 발생시 즉각적 탐지 및 대응을 위한 데이터 분석법에 관심이 증가하고 있다. 서울 문래동, 인천, 포항의 경우에서도 알 수 있듯이, 수질사고 발생 시 원인물질의 시공간적 이송 또는 전파에 대한 정보는 사고대응에 유용하게 활용된다. 본 연구는, 비정상적인 수질변화의 계통 내 전달 시간을 계산하기 위해 고해상도 수질 스마트 미터 데이터에 기반한 데이터 분석법을 개발하였다. 물공급 하류방향의 수질변화 전달 시간 정량화를 위해 화음탐색법 기반 동적시간워핑(Dynamic time warping; DTW) 기술을 이용하였고, 원데이터의 전처리를 위해 이동평균필터링을 수행하였다. 개발된 분석법은 A시 생산 및 배·급수과정의 감시지점에서 10초 단위로 계측된 다양한 수질변수(pH, 탁도, 잔류염소, 전기전도도, 수온 등)의 공간적 변이 전파시간을 결정하기 위해 적용되었다. 분석에 활용한 데이터는 데이터 통신 및 측정 기기에 의한 이상값과 운영상황의 변화에 따라 변동한 값을 처리하기 이전의 데이터이다. 데이터 품질에 의한 영향을 배제하기 위해 이상값이 발생하지 않은 기간을 파악한 후, 그 기간에 대하여 분석하였다. 계통 내 위계에 따라 두 지점의 측정값의 전파시간을 정량화한 결과, 지점에 따라 전파시간이 다르게 나타났다. 또한, 같은 두 지점에 적용한 결과라도 DTW를 적용하는 기간과 이동평균필터링의 크기에 따라 수질변화 전달 시간이 다르게 나타나는 것을 확인할 수 있었다. 본 연구에서 개발된 분석법은 다변량 수질변수 간의 영향관계를 파악하는데 확장 적용이 가능하다. 또한, 이 방법의 실시간 적용을 통해 동적으로 변화하는 전달시간을 주기적, 공간적으로 갱신하여 관망 수질 변화 모니터링이 가능하다.

  • PDF

Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline (상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석)

  • Lee, Hohyun;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.834-840
    • /
    • 2021
  • The management and installation methods of pressure gauges in water supply pipeline are not efficiently regulated and their installations are different in each site. In this paper, various domestic and overseas documents are examined about the pressure gauge. In order to improve the efficiency of operation management such as pipeline network and pump operation, water pressure needs to be measured as accurate as possible, by which decision making for optimal pipe network can be achieved. To get the goal, the installation of pressure gauge should be reviewed about where and how to install. In this study, an optimal horizontal distance test is conducted, in which pressure value variation is monitored and analyzed according to up and down stream distances and valve flow control, and a optimal vertical position test is also analyzed by installing the pressure gauges vertically from the up(180°) to the bottom (0°) of the pipeline.

Evaluation for conjunctive operation of multi-regional water supply system through risk analysis (위기대응 취약성 분석을 통한 광역상수도 연계운영 평가)

  • Hwang, Jinsoo;Choi, Taeho;Hong, Gonghyun;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.

Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems (상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정)

  • Hong, Sungjin;Lee, Chanwook;Park, Jiseung;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.1015-1024
    • /
    • 2020
  • Recently, water pollution accidents have continued to occur in pipelines such as red water Incheon and Seoul. In order to recognize this water quality problem, it is necessary to install a water quality sensor in an appropriate location and measure it in advance to detect or block the water supply to the water faucet of the shelter. However, there are limitations, such as maintenance costs, to installing multiple water meters in all pipelines. Therefore, this study proposed a methodology for determining and prioritizing the installation location of flow-based water quality sensor for the recognition of water quality problems in pipelines. We applied the proposed procedure to the pipe break scenario. The results of the determination of the location of the water quality sensor were presented by applying it to the pipe network that actually operates the emergency pipe in Korea. The result of the decision showed that in the event of abnormal situation caused by the destruction of individual pipes, the flow rate of the pipes around the aqueduct and the tank may change rapidly, resulting in water quality accidents caused by turbidity. In the future, it is expected that the water quality monitoring point selection method, such as establishing an external pipe operation plan for pipe cleaning, will utilize the procedure for determining the location of the water quality sensor according to the velocity.

Implementation of Windows Based Underground Pipe Network Monitoring System Reproduced with Embedded Program (임베디드 프로그램으로 재구성한 윈도우 기반 지하관망 모니터링 시스템의 구현)

  • Park, Jun-Tae;Hong, In-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.8
    • /
    • pp.1041-1049
    • /
    • 2011
  • According to the development of society and infrastructure, effective underground facility management is growing more important them ever. In the process various monitoring systems are studied and developed for water works pipe-network. Especially, RTD-1000 system with the based on Pc. Reflector-monitoring device is constructed and steered by several local governments. But, this system have to be improved result from based on PC system structure at the point of resource management, heat, power consumption and size. In this paper, RTD-2000 is proposed are a substitution of improved RTD-1000 with many respect and portable one. This system is designed and implemented with ARM-9 development kit based on WinCE and LCD eliminate TDR(Time Domain Reflector-Meter). Various surveillance programs based on windows are mounted on RTD-1000 are replaced with dedicated embedded application softwares. Simulation and evaluation for performance comparison are performed for the prove of effectiveness of RTD-2000.

Real-time Optimal Pump Operation for Water Transmission Network (송·배수시스템의 실시간 최적 펌프운영)

  • Kim, Kyung Wan;Choi, Jeong Wook;Kang, Doosun;Kim, Byug Seop;Kang, Min Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.158-158
    • /
    • 2015
  • 대부분의 대규모 배수지는 고지대에 위치함으로써 자연유하를 통해 배, 급수지역으로 용수를 공급한다. 이를 위해 배수지 전단에는 가압장이 위치하여 정수장에서 처리된 용수를 고지대에 위치한 배수지로 송수한다. 이때 가압장에서 발생하는 전력소비량이 매우 높은 것으로 알려져 있으며, 효율적인 펌프운영을 통해 상당한 전력비용 절감이 가능할 것으로 판단된다. 일반적인 가압장의 운영은 시스템 운영자의 경험을 토대로 해당 가압장에 연결된 배수지의 수위에 따라 펌프의 작동여부를 결정하는 방법이 주로 사용되고 있다. 이러한 운영방법은 용수공급의 안전성을 우선시함으로써 배수지의 수위를 일정하게 유지하고자 빈번하게 펌프를 작동하게 되고 따라서 가압장에서 소모되는 전력량이 커서 운영효율 측면에서는 바람직하지 않다고 할 수 있다. 또한 빈번한 펌프의 작동으로 인해 펌프의 수명이 단축될 뿐만 아니라, 배수지내 용수의 수질저하 문제도 발생할 수 있다. 본 연구에서는 효율적인 펌프장 운영을 위해 급수지역의 24시간 용수사용량을 예측하고, 그에 따른 펌프장의 가압 유량 및 양정을 파악하여 적정용량의 펌프를 선정하고 운영함으로써 펌프의 운영비용의 최소화 및 안정적인 용수공급을 동시에 달성하고자 한다. 이를 위해, 실시간 최적화 모형을 개발하였다. 개발된 최적화 모형은 상수관망해석 프로그램(EPAENT)을 연계하여 수요절점의 수압조건 및 운영상황을 모의하였다. 최적화 기법으로는 유전자알고리즘을 사용하였으며, 실제 시스템의 운영상황를 반영하기 위한 다양한 제약조건(operational constraints)을 적용하였다. 개발된 모형은 정속펌프(혹은 On/Off 펌프) 뿐만 아니라, 최근 실무에서 널리 사용되고 있는 변속펌프(variable speed pump)를 추가적으로 고려하였다. 개발된 모형은 국내에서 실제 운영되고 있는 송, 배수 시스템에 적용하여 모형의 실무 적용가능성을 검증하였다.

  • PDF

Sensitivity analysis of pump and tank sizes on water network operation and water age (송수펌프용량 및 배수지규모에 따른 송·배수시스템의 운영비용 및 체류시간 분석)

  • Kim, Kangmin;Choi, Jeongwook;Jung, Donghwi;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.803-813
    • /
    • 2017
  • Recently, various studies have been conducted to optimize the pump operation scheduling and/or the pump/tank size minimizing the system cost of water distribution network. Prior to that, it is important to understand the sensitivity of pump/tank size on the system cost and overall water quality. Here, we have performed the sensitivity analysis to investigate the effect of pump/tank size on the economic cost (construction and operation) and water quality (water age). The analysis was applied on a real, large-scale water transmission network currently operating in South Korea. The results revealed that the pump/tank size has a strong influence on system construction/operation costs. Especially, the tank size has a significant effect on the system-wide water quality. In the case of applied networks, the operating cost decreases as the capacity of the facility increases, but the design cost increases. Using a sensitivity analysis, a suitable range of pump/tank size could be suggested to minimize costs and stabilize the water quality at the same time prior to a system design.