• Title/Summary/Keyword: 상부 Pool

검색결과 19건 처리시간 0.026초

고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구 (Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer)

  • 박용철;박종호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석 (Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor)

  • 최정운;이선일;박기정;서경우
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제5권2호
    • /
    • pp.135-143
    • /
    • 2017
  • 국내 유일의 연구용원자로인 하나로(Hi-flux Advanced Neutron Application ReactOr)는 다목적으로 중성자를 이용하기 위해 개방형 수조 내 노심이 존재하는 구조이며, 노심에서 발생되는 핵분열 열을 제거하기 위한 일차 냉각계통, 그리고 연결된 유체계통이 구비되어 있다. 원자로 수조 상부 근방에서 진행되는 방사성 작업 시 작업자의 방사능 피폭을 최소화하기 위해 수조고온층계통에 의해 상부에 고온층이 형성되어 있으며, 다소 저온 영역에 있는 방사능 가스 및 이물질이 상부로 올라오는 것을 방지하기 위해 수조수 온도를 $50^{\circ}C$이하로 제한하고 있으며 이를 위해 수조수관리계통이 연결되어 있다. 수조수관리계통의 구비된 판형열교환기의 열용량을 정상운전 조건에서 260 kW가 되도록 설계하여 각 수조에서 발생되는 열원을 제거하는지에 대해 평가하였고, 원자로 운전 모드와 관계없이 정상적으로 유체계통이 운전된다면 각 수조의 수조수 온도는 제한치 이하를 유지하고 있음을 확인하였다.

구형 면진유체저장조의 지진시 거동해석 (Seismic Response Analysis of Rectangular Tank with Base-Isolation System)

  • 전영선;최인길;황신일;김진웅
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.107-113
    • /
    • 1995
  • 사용후핵연료 저장조는 지진하중에 대하여 운영기간중 자체의 구조적 건전성 및 저장된 사용후핵료의 안전성을 확보할 수 있어야 한다. 본 연구에서는 LRB 면진장치를 설치한 사용후핵연료 면진저장조의 지진시 거동특성을 파악하기 위하여 서로 다른 특성을 갖는 두종류의 지진에 대하여 지진해석을 하여 그 결과를 비면진 저장조에서의 응답과 비교하였다. 면진장치를 사용함으로써 지진시 상부구조로 전달되는 지진력과 응답을 크게 감소시켜 저장조와 저장된 사용후액연료의 안전성 확보에 유리한 것으로 나타났다.

  • PDF

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.49-54
    • /
    • 2002
  • HANARO, 30 MW of research reactor, was installed at the depth of 13m in an open pool. The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the cote. The rest, $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to prevent the radiated gas from being lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection, and increased the radiation lovel on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2 m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated at a higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated by Visual Basic Program. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss increased. And it was verified that the radiation level above was reduced mote safely by increasing the capacity of heater.

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF

면진수조의 2차원 동적 해석기법 개발 (2-D Dynamic analysis method of base-isolated pool structure)

  • 전영선;최인걸;김진웅
    • 전산구조공학
    • /
    • 제8권3호
    • /
    • pp.67-74
    • /
    • 1995
  • 본 연구에서는 면진수조의 2차원 동적 해석기법을 개발하고 축소모델을 사용한 진동대실험을 통하여 해석기법의 타당성을 검증하였다. 수조의 벽체는 집중질량을 사용하여 모델링하였으며 유체의 부가질량을 벽체의 절점에 부가함으로써 유체의 동수역학적인 영향을 고려하였다. 면진수조의 운동방정식은 벽체와 유체로 구성된 상부구조의 운동방정식과 바닥슬래브와 면진장치로 구성된 하부구조의 운동방정식을 연계하여 구하였다. 진동대 실험에서는 투명한 아크릴로 제작한 모형수조를 사용하였으며 면진장치는 4개의 고감쇠 적층 고무베어링(High Damping Laminated Rubber Bearing)을 사용하였다. 축소모델에 의한 실험결과는 대체적으로 해석결과와 잘 일치하였으며 계산결과가 다소 보수적인 것으로 나타났다.

  • PDF

물의 포화풀비등에서 다발효과를 평가하기 위한 실험식 개발 (Development of an Empirical Correlation to Evaluate the Bundle Effect in Saturated Pool Boiling of Water)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 대기압 하에서 포화 상태를 유지하는 물의 내부에 잠긴 탠덤 튜브에 적용하기 위한 실험적 상관식을 새롭게 개발하였다. 상관식은 다발효과를 계산하기 위한 것으로 실험에서 측정한 값과 최소자승법을 사용하여 결정하였다. 상관식의 적절함을 평가하기 위해 통계분석을 수행하였다. 상관식은 실험값을 ${\pm}8%$ 범위 내에서 잘 예측함을 확인하였다. 상관식의 적용 범위는 피치=28.5~114mm, 방위각=$0^{\circ}{\sim}90^{\circ}$, 경사각=$0^{\circ}{\sim}90^{\circ}$, 상부 및 하부 튜브 열유속=$0{\sim}120kW/m^2$이다.