• Title/Summary/Keyword: 상부시설

Search Result 174, Processing Time 0.026 seconds

Numerical Analysis on the Crack Control of Concrete Lining Reinforced by Composite Fibers (복합섬유보강 콘크리트 라이닝 부재의 균열제어를 위한 수치해석적 연구)

  • Yang, Woo-Shik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • The concrete lining of a tunnel constructed by NATM used to be regarded as facing material which does not support any load from the surrounding ground. But the recent appraisal of the decrepit tunnels revealed that rockbolts and shotcrete deteriorate with time resulting in loss of supporting capability. Consequently, concrete lining has to support part of the load which used to be supported by rockbolts and shotcrete, and thus should be regarded as the final supporting structure in a tunnel. One of the common, and perhaps the most serious problem in concrete lining is the longitudinal cracks taking place at the tunnel crown. The longitudinal cracks, mostly related to the construction procedures, can be developed by many reasons such as the lack of thickness, wrong materials, bad curing environment, and excessive external forces. Many efforts has been made to control and suppress these cracks but efficient and economic way is yet to be found. For efficient crack control in concrete lining, reinforcement by composite fibers, which is the mixture of steel fiber and nylon fiber, is suggested in this study.

  • PDF

Workability of Polymeric Concrete for Lunar Infrastructure (달 시설물을 위한 폴리머 콘크리트의 시공성 연구)

  • Lee, Jaeho;Lee, Tai Sik;Ann, Ki Yong;Chang, Byung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.507-512
    • /
    • 2017
  • For manned planetary exploration, human beings are developing technologies that can permanently reside on the planet, and the basic three elements of residence, such as clothing and shelter, are required to support essential technologies in construction. In order to develop infrastructure construction technology internationally, various materials and methods such as local cementation, sulfur and aluminum have been tried. in this study, a purpose is proposed a polymer concrete construction validation technology that appropriates the conditions required for manmade exploration in order to develop construction infrastructure material technology using polymer. Concrete specimens with a 10% weight ratio polymer prepared by heating on the bottom were stabilized after 2 hours of heating, and the strength was lower than the top heating method, but the solidifying speed was 2 times faster. These results are expected to be applicable not only to construction of lunar facilities for manned exploration but also to improve the construction of infrastructures such as roads and levees to prevent dust.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.

Construction of Hydrogeological Model for KURT Site Based on Geological Model (KURT 연구지역에서 지질모델을 이용한 수리지질모델의 구축)

  • Park, Kyung-Woo;Ko, Nak-Yeol;Ji, Sung-Hoon
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.121-130
    • /
    • 2018
  • The KURT (KAERI Underground Research Tunnel) is a research tunnel which is located in KAERI (Korea Atomic Energy Research Institute) site. At KURT, researches on engineering and natural barrier system, which are the most important components for geological disposal system for high level radioactive waste, have been conducted. In this study, we synthesized the site characteristics obtained by various types of site investigation to introduce the geological model for KURT site, and induced the 3-D hydrogeological model for KURT site from the geological model. From the geological investigation at the surface and boreholes, four geological elements such as subsurface weathered zone, upper fractured rock, lower fractured rock and fracture zones were determined for the geological model. In addition, the geometries of these geological elements were also analyzed for the geological model to be three-dimensional. The results from 3-D geological model were used to construct the hydro-geological model for KURT site, which is one of the input data for groundwater flow modeling and safety assessment.

An Artificial Recharge Test and Its Numerical Simulation for the Analysis of Seepage in the Songsanri Tomb Site of Kongju (공주 송산리고분군 누수현상 원인 분석을 위한 인공함양시험 및 수치모델링)

  • 구민호;서만철
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 1999
  • An artificial recharge test was performed to analyze the source of seepage observed inside the Songsanri tombs Kongju during the rainy season. In order to simulate simulate the test, a two-dimensional unsaturated groundwater flow model was developed. By the measured water level variation in the observation wells and in the artificail water tank, the model was cailbrated to estimate the model parameters such as fitting parameters in the constitutive relations(n and $\alpha$), the saturated volumetric water content, the residual volumetric water content, and the saturated hydraulic conductivity. Using the calibrated parameters, the recharge test was simulated. The results of the test and simulation show that the major source of the seepage is the downward groundwater flow through cracks in the protection layer the tombs. It was also analyzed by the steady state simulation that, with a perfect protection layer, a long-term precipitation that, with a perfect protection layer, a long-term precitation could cause only 10% increase of the effective saturation around the north side of the Muryong royal tomb by infiltration of the unsaturated groundwater from the North. Therefore, it is concluded that the most urgent protection plan for the tombs with respect to seepage is to reconstruct an effective waterproof-layer rather than a trenched drainage system.

  • PDF

Biofiltration of Odorous Compounds in Municipal Solid Waste Landfill Gases (생물탈취상에 의한 도시폐기물 매립지가스내 악취물질의 처리)

  • 남궁완;박준석;황의영;이노섭;인병훈;김정대
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • Biofiltration is an attractive technique for elimination of VOCs and odorous compounds from low-concentration, high-volume waste gas streams because of its simplicity and cost-effectiveness. The objective of this study was to estimate the removal characteristics of Odorous Compounds including $H_2$S, $NH_3$End BTEX in MSW landfill gases. This Study was conducted at Nanjido landfill site. A compost from the Nanjido composting facility was used as a filling material for biofiltration. Extracted landfill gases were injected into biofilter reactors after mixing with air. Experiments were performed in an incubator being set to $20^{\circ}C$ $H_2$S concentrations were monitored at the depths of 25, 50, 75 and 100cm from the bottom Of the biofilter reactors. 98% of $H_2$S was removed at the filling depth of only 25cm. NH$_3$removal rate was about 85%. Toluene removal rate was the highest among BTEX. Significant pH drop of a filling material was not observed during the biofilter operation of 1 month. Without mixing the landfill gas stream with all, the removal rate of $H_2$S decreased down to 30%.

  • PDF

A Study on the Development of New SRC Lining Board (신형 SRC 복공판의 개발에 관한 연구)

  • Kown Beom-Jun;Park Do-Uk;Kim Yong-Su
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.4 s.26
    • /
    • pp.172-180
    • /
    • 2005
  • The purpose of this study is to suggest a new SRC(Steel Ready mixed Concrete) lining board. The research method of this study includes problem analysis of existing lining boards a constant load test and a fatigue test. The results of this study are as follow : 1) the suggested new lining board improves the function and reduce slipperiness than existing lining boards. 2) the strength of the new SRC lining board is analyzed as superior than existing lining boards from the results of constant load test and fatigue test.

Simple Empirical Attenuation Relationship for Potential Nuclear Power Plant Sites (원자력발전소의 단순화 된 실증적 지진감쇄 관계)

  • Tanwa, Kankang;Eric, Yee
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.9
    • /
    • pp.43-49
    • /
    • 2018
  • Seismic hazard assessments are performed on a variety of infrastructure projects. One component of a seismic hazard assessment is the attenuation relationship. Several attenuation relationships have been developed over the decades to predict peak ground acceleration under a variety of site conditions. For example, many attenuation relationships were designed to estimate peak ground acceleration, as well as other intensity measures, under a variety of soil conditions, mostly using the average shear wave velocity for the upper 30 m of earth material as a classification scheme. However, certain types of infrastructure, such as tunnels and nuclear power plants, are typically founded on and in bedrock. Using data from Japan, we developed a simple correlation to estimate peak ground acceleration for rock sites and compare the results from another popular attenuation relationship. Results indicate the popular attenuation relationship to be less than the proposed model for distances less than 200 km.

Analysis of Solute Transport with Steady State Groundwater Flow in Layered Aquifer (정상 지하수흐름을 갖는 층상대수층에서의 용질이동해석)

  • Lee, Seung-Han;Jeong, Il-Mun
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.23-34
    • /
    • 1997
  • The Nanji-Do ladnfill is an ill-conditioned reclaimed land without pollution intercepting facilities, and has high ground water table and deep stratum. The purpose of this study is to analyze the solute transport in steady-state groundwater flow and to predict the solute dispersion in Nanji-Do landfill using HST-3D model. As results, the groundwater flows radially outward from the center of No. 1 and No. 2 landfills, and large amount of runoff is moved into Han River. The predicted relative concentration of total dissolved solute(TDS) at two years later was 0.25 in the weathering zone, 0.26 in the lower alluvium, and 0.28 in the upper alluvium. Thus, the further pollution to bottom rock and Han River was predicted by comparing the corresponding present values of 0.29, 0.32 and 0.35.

  • PDF

The Formation of Transient Saturation Zone and the Subsurface flow on the Steep Hillslope by Rains (降雨에 의한 急斜面의 일시적인 飽和帶形成과 중간류 流出)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.167-176
    • /
    • 1998
  • On steep hillslopes, saturation zone formations and subsurface flows were monitored through the observation systems of observation wells, tensiometers and trenches. By the 103 mm rain which had fallen on the hillslope with dry soil moisture, the saturation zone began to be formed at the top of hillslope during the rain and developed to be formed within a few hours after the end of rain on all hillslope. Subsurface water outflowed mainly from the soil profile of 0-40 cm depth, but did not outflow from the one of 40-80 cm depth. This saturation zone seemed to be formed by partially saturation of soil. This resulted for two reasons. Firstly, the saturation zone was formed by a smaller amount of rain than that required. Secondly the soil at a certain depth below the water table was unsaturated. Saturation zones formed by pre-rains responded rapidly to rains and subsurface water outflowed mainly from the soil profile of 40-80 cm depth simultaneously with the rising of the water level. The rates of subsurface discharge from the soil profile of 40-80 cm depth to the precipitation were related to the antecedent precipitation although the maximum water levels of saturation zone formed by four rains were similar.

  • PDF