• Title/Summary/Keyword: 상대표준편차

검색결과 311건 처리시간 0.193초

Rainfall Seasonality and Estimation Errors of Area-Average Rainfall (강수의 계절성과 면적평균강수량의 추정오차)

  • Yoo, Chul-Sang
    • Journal of Korea Water Resources Association
    • /
    • 제35권5호
    • /
    • pp.575-581
    • /
    • 2002
  • This study evaluates the variation of estimation error of area-average rainfall due to rainfall seasonality. Both the cases considering and not considering the spatial correlation are compared to derive the characteristics of estimation error. Similar cases with different accumulation time without considering the rainfall seasonality are also investigated. This study was applied to the Geum-river basin with total 28 rain gauge measurements haying more than 30 years of daily rainfall measurements. As results of the study we found that: (1) The absolute estimation error of monthly area-average rainfall show strong seasonality like the total rainfall amount. However, the relative estimation error normalized by its mean was estimated to have similar values about 5 to 8% except January and December. (2) The relative estimation error of annual area-average rainfall estimated was found to have the estimation error about 3% of its annual mean. (3) However, the relative estimation error normalized by the standard deviation remains almost the same for both monthly and annual rainfall amounts, which was estimated about 11% of its standard deviation. (4) Finally, the estimation error without considering the spatial correlation was found to become almost twice the estimation error with considering the spatial correlation.

DEA를 이용한 펀드(fund)의 성과 평가

  • Gang, Maeng-Su;Hong, Hyo-Jeong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 한국경영과학회 2006년도 추계학술대회
    • /
    • pp.409-412
    • /
    • 2006
  • 펀드의 성과 평가는 펀드선택 의사결정시 가장 중요한 고려요인이다. 전통적인 펀드 성과평과 지표인 샤프비율이나 트레이너 비율은 운용비용과 거래비용 등과 같은 다양한 요소들을 반영하지 못하고 있다. 펀드의 여러 수익과 비용요인들을 반영하기 위해, 본 연구에서는 DEA를 이용하여 펀드의 상대적인 효율성을 측정하였다. 분석자료는 2005년 12월 31일까지 국내에 존재하는 3년 이상 운용된 67개의 장기펀드를 대상으로 분석하였다. 입력변수는 비용과 관련된 총 보수율, 월수익률의 표준편차, 펀드 규모를 나타내기 위한 평균설정좌수를 이용하였고 출력변수는 이익과 관련된 예상 월평균수익률과 시장포트폴리오의 월수익률을 상회한 기간의 비율을 사용하였다. 본 연구결과, DEA를 통해 수익률만으로는 평가할 수 없는 펀드의 운용능력을 평가할 수 있었다.

  • PDF

Measuring Fund Performance: Style Analysis and DEA Approach (스타일분석과 DEA를 활용한 펀드의 운용성과 분석)

  • Min Jae-Hyeong;Gu Gi-Dong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 대한산업공학회/한국경영과학회 2006년도 춘계공동학술대회 논문집
    • /
    • pp.1777-1783
    • /
    • 2006
  • 일반적으로 펀드평가는 절대수익률이나 위험을 조정한 샤프지수 또는 트레이너 지수를 이용하고 있는데, 이러한 방법은 벤치마크 지수를 기준으로 평가하여 펀드규모, 비용 등을 고려한 펀드간의 상대적 성과는 측정하지 못하고 있다. 펀드간의 상대적 성과평가는 펀드의 실질적인 효율성을 측정할 수 있다는 측면에서 펀드평가의 유용한 수단이 될 수 있다. 본 연구에서는 샤프의 스타일 분석을 이용하여 펀드의 유형을 분류하고, DEA를 이용하여 펀드간의 상대적인 성과를 측정한다. 분석자료는 2000년 1월부터 2005년 12월 31일까지의 주식형 펀드의 월간수익률, 수익률 표준편차, 펀드비용, 펀드규모, 운용기간, 샤프지수 등을 이용한다.

  • PDF

Scene Change Detection Using Global Direction & Center of Edge (전역적 에지의 중점 및 방향성을 이용한 장면 전환 검출)

  • Lee, Jeong-Bong;Yoon, Pil-Young;Park, Jang-Chun
    • Annual Conference of KIPS
    • /
    • 한국정보처리학회 2002년도 춘계학술발표논문집 (상)
    • /
    • pp.751-754
    • /
    • 2002
  • 장면 전환 검출(Scene Change Detction)수행 방법으로 객체 인식에 의한 검출이 아닌 전체 영상의 전역적인 형태 흐름을 기반으로 한 검출 시스템을 제안한다. 형태흐름의 변하는 영상의 전체적 모양에 관한 전역적 특징을 이용하여 영상내에 존재하는 에지, 에지의 중심, 표준 편차 및 에너지의 분포 변환에서 추출할 수 있다. 본 논문에서는 효율적인 에지 검출을 위하여 미디언 필터와 개량형 라플라시안 필터를 사용한다. 일반적으로 이용되는 라플라시안 필터를 사용하였을 때 획득할 수 있는 에지 정보보다 우수한 정보를 얻을 수 있었고 보다. 정착한 장면 전환을 검출하기 위해 이 에지 정보를 수평$(0^{\circ})$, 수직$(90^{\circ})$, 대각선$(45^{\circ},\;135^{\circ})$ 방향으로 세분화한 뒤에 프레임간에 각도 방향별 에지 정보를 파악하여 방향별 에지 에너지(Energy of edge)의 상대적인 성분 분포의 비교를 수행함으로써 정확성을 높였다.

  • PDF

Simultaneous Determination of Phthalates(DMP, DEP, DBP, BBP, DEHP, DnOP) by Solid Phase Microextraction-GC/MS (Solid Phase Microextraction-GC/MS에 의한 플라스틱가소제(DMP, DEP, DBP, BBP, DEHP, DnOP)의 동시분석)

  • Lee, Jae-Hee;Bae, Jun-Hyun;Kang, Jun-Gill;Kim, Youn-Doo
    • Journal of the Korean Chemical Society
    • /
    • 제48권1호
    • /
    • pp.17-27
    • /
    • 2004
  • A procedure based on solid phase microextraction extraction(SPME)-GC/MS has been developed for the simultaneous analysis of plasticizers. The plasticizers investigated in this study are dimethyl phthalate(DMP), diethyl phthalate(DEP), dibutyl phthalate(DBP), benzylbutyl phthalate(BBP), diethylhexyl phthalate (DEHP), di-n-octyl phthalate(DnOP). The limit of detection(LOD) was 0.163~0.299 with relative standard deciation(RSD) of 5.85~15.80% for these compounds. At water reserviors of Han, Geum, Nakdong and Sumjin rivers, only DBPand DEHP were detected at trace level, 0.192~1.270 ng/ml for DBP and 0.077~1.102 ng/ml for DEHP depending on the river.

Potentiometric Characteristics of Acidic Drug Selective membrane Electrodes using Di-2-pyridyl ketone (디-2-피리딜케톤을 이용한 산성의약품 선택성 막전극의 특성)

  • Lee, Dong-Yup;Lee, Jae-Yoon;Ahn, Moon-Kyu
    • Analytical Science and Technology
    • /
    • 제16권4호
    • /
    • pp.320-324
    • /
    • 2003
  • Acidic drug selective electrodes based on metal(II)-di-2-pyridyl ketone-acidic drugs ternary complex as electroactive material were prepared. The metal ions, $Fe^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$ were used. Nitrophenyl ether series were used as plasticizers. The electrodes exhibit a fast stable and linear response for $5{\times}10^{-5}{\sim}10^{-3}mol/L$ mefenamic acid (MA) in borate buffer solution (pH 8.9) and ibuprofen(Ib) in phosphate buffer solution (pH 7.0). The recovery test for mefenamic acid and ibuprofen using standard addition method were 99.0% and 98.4% with relative standard deviation of 2.4% and 2.6% respectively.

Solvent Selection for the Detection of Siloxanes in Landfill gas (매립가스내 규소화합물류 검출을 위한 용매선택에 관한 연구)

  • Kim, Nack-Joo;Choi, Ju-Mi;Ji, Eun-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제29권8호
    • /
    • pp.915-921
    • /
    • 2007
  • As a preliminary measurement of siloxanes in landfill gas(LFG), this study was conducted to determine the best suitable solvent applicable to the extraction of siloxanes in the domestic landfill using liquid-absorption method. Three solvents of n-hexane, acetone, and methanol were tested and the results obtained from GC analysis for each solvent were compared to their properties. Results showed that the resolution in the GC spectrum was the best from methanol due to the lack of overlapping of the peaks between silane and solvent. The detected siloxanes concentration were varied at maximum 2.6 times depending on the types of solvent as well as extraction velocity and impinger steps. In total, the highest concentration of siloxanes was obtained from methanol, which showed ideal pattern in the absorption of each impinger step and the least relative standard deviation. Accordingly, it is concluded that methanol is the most suitable solvent for the extraction of siloxanes in the domestic landfill. However, it is considered that solvent suitability can vary depending on the waste components and landfill record in landfills.

A Comparison of Sonication and Microwave-assisted Extraction Method for Speciation of Arsenic in Fish Tissue, DORM-2 (어류중 비소의 종분화 분석을 위한 초음파 추출법과 마이크로파 추출법의 비교)

  • Yoon, Cheol-Ho;Park, Yong-Chul;Hong, Jong-Ki
    • Analytical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.134-142
    • /
    • 2003
  • Comparison of a microwave-assisted extraction with sonication extraction was performed for arsenic speciation in fish tissue with chromatographic separation and inductively coupled plasma mass spectrometry detection. The detection limits of arsenicals with ultrasonic nebulizerand cross-flow nebulizer were shown to be similar. The arsenicals investigated were arsenobetaine (AsB), arsenite [As(III)], dimethylarsine acid (DMA), monomethylarsonic acid (MMA), arsenate [As(v)], and phenylarsonic acid (PAA). Quantitative extraction of arsenicals from dogfish muscle, DORM-2, standard reference material of NRCC (National Research Council of Canada) was achieved using 50% (v/v) methanol-water in both extraction methods. Extraction efficiency of arsenobetaine in both methods is greater than 82% with RSDs on replicates of less than 5%. The concentrations of AsB determined in extract of microwave assisted extraction and sonication methods were $14.18{\pm}0.42mg\;kg^{-1}$ and $13.54 {\pm}0.84mg\;kg^{-1}$, respectively. And the concentrations of DMA were $0.45{\pm}0.06mg\;kg^{-1}$ and $0.44{\pm}0.06mg\;kg^{-1}$, respectively.

Determination of free amino acids in the plasma samples of normal subjects and schizophrenic subjects in Korea by HPLC (HPLC를 이용한 한국인 정상인과 정신분열증 환자의 혈장 중의 유리 아미노산의 정량)

  • Park, Seong Soo;Park, Song-Ja;Pyo, Hee Soo;Park, Jongsei;Park, Taek Kyu;Shin, Young Min
    • Analytical Science and Technology
    • /
    • 제8권3호
    • /
    • pp.229-236
    • /
    • 1995
  • Multiple-step gradient method was used for the analysis of free amino acids in physiological fluids by high-performance liquid chromatography with diode array detector on the Amino Quant $C_{18}$ column under the condition of pH 7.2 of buffer solutions. Plasma samples of normal Korean people and abnormal Korean people who have schizophrenia were subjected to derivatization with o-phthalaldehyde in the presence of 3-mercaptopropionic acid. Quantitative analysis of amino acids in physiological fluids by internal standard method gave highly reproducible results within a relative standard deviation of less than 2~6%. And amino acids amounts of physiological fluids of Korean people gave some different results from those of foreigners. There was large differences in tyrosine amount between normal and abnormal man.

  • PDF

Coulometric Determination of Plutonium in PWR Spent Fuels (PWR 사용후핵연료내 플루토늄의 전기량적 정량)

  • Sohn, Se Chul;Suh, Moo Yul;Kim, Jung Suk;Song, Byung Chul;Jee, Kwang Yong;Choi,In Kyu;Kim, Won Ho
    • Journal of the Korean Chemical Society
    • /
    • 제44권6호
    • /
    • pp.581-586
    • /
    • 2000
  • Separation and coulometric titration method were applied for the determination of plutonium content in samples of PWR spent fuel. Plutonium was separated on an anion exchange(AG MP-1) column and determined by the controlled-potential coulometric titration. In this study, we discussed some experimental conditions related to the separation and determination of plutonium in PWR spent fuel samples. Average accuracy(recovery of plutonium) for the determination of 0.230∼3.02 mg plutonium standard was 99.36%. Average precision(relative standard deviation, RSD) for the determination of 0.250∼0.450 mg plutonium in PWR spent fuel samples was 0.38%.

  • PDF