Browse > Article
http://dx.doi.org/10.5012/jkcs.2004.48.1.017

Simultaneous Determination of Phthalates(DMP, DEP, DBP, BBP, DEHP, DnOP) by Solid Phase Microextraction-GC/MS  

Lee, Jae-Hee (Korea Water Resources Corporation)
Bae, Jun-Hyun (Department of Environmental Engineering, Anyang University)
Kang, Jun-Gill (Department of Chemistry, Chungnam National University)
Kim, Youn-Doo (Department of Chemistry, Chungnam National University)
Publication Information
Abstract
A procedure based on solid phase microextraction extraction(SPME)-GC/MS has been developed for the simultaneous analysis of plasticizers. The plasticizers investigated in this study are dimethyl phthalate(DMP), diethyl phthalate(DEP), dibutyl phthalate(DBP), benzylbutyl phthalate(BBP), diethylhexyl phthalate (DEHP), di-n-octyl phthalate(DnOP). The limit of detection(LOD) was 0.163~0.299 with relative standard deciation(RSD) of 5.85~15.80% for these compounds. At water reserviors of Han, Geum, Nakdong and Sumjin rivers, only DBPand DEHP were detected at trace level, 0.192~1.270 ng/ml for DBP and 0.077~1.102 ng/ml for DEHP depending on the river.
Keywords
Solid Phase Microextraction-GC/MS; Plasticizer; Simultaneous Analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jara, S.; Lysebo, C.; Creibrokk, T.; Lundances, E. Analy. Chim. Acta, 2000, 407, 165.   DOI   ScienceOn
2 Koch, H. M.; Gonzalez-Reche, L. M.; Angerer, J. J. Chromatogra. B 2003, 784, 169.   DOI   ScienceOn
3 Brossa, L.; Marce, R. M.; Borrull, F.; Pocurull, E. J. Chromatogra. A 2002, 963, 287.   DOI   ScienceOn
4 McLafferty, F. W.; Turecek, F. Interpretation of mass spectra. fourth edition, University Science Books, 1993.   DOI   ScienceOn
5 Munch, J. W. Determination of organic compounds in drinking water by liquid solid extraction and capillary column GC/MS, National Exposure Research Laboratory Office of Research and Development U.S. Environmental Protection Agency, 1995.   DOI   ScienceOn
6 Eichelberger, J. W.; Behymer, T. D.; Budde, W. L. Determination of organic compounds in drinking water by LSE and capillary column GC/MS, Revision 2.2-EPA EMSL-Ci, May 1991.   DOI   ScienceOn
7 Kambia, K.; Dine, T.; Gressier, B.; Germe, A. F.; Luyckx, M.; Brunet, C.; Michaud, L.; Gottrand, F. J. Chromatogra. B 2001, 755, 297.   DOI   ScienceOn
8 Prokpkova, G.; Holadova, K.; Poustka, J.; Hajalova, J. Analy. Chim. Acta 2002, 457, 211.   DOI   ScienceOn
9 Petrovic, M.; Eljarrat, E.; de Alda, M. J. L.; Barcelo, D. J. Chromatogra. A 2002, 974, 23.   DOI   ScienceOn