• 제목/요약/키워드: 상대전극전위

검색결과 23건 처리시간 0.029초

흑염소 간-조직과 Ferrocene 매개체를 사용한 과산화수소정량 전류법 바이오센서 (Amperometric Biosensor for Hydrogen Peroxide Determination Based on Black Goat Liver-Tissue and Ferrocene Mediation)

  • 권효식;박인근;김양숙
    • 대한화학회지
    • /
    • 제48권5호
    • /
    • pp.491-498
    • /
    • 2004
  • 흑염소의 간-조직과 ferrocene을 탄소반죽 전극에 고정하여 과산화수소를 정량할 수 있는 전극을 만들었다. Ag/AgCl 전극에 대하여 $-0.3{\sim}+0.0\;V$의 전위 범위에서 전극의 감도를 관찰하였으며 전극의 감응시간은 12 s로 나타났다. 전극의 검출한계는 2.25${\times)10^{-6}M$ (S/N=3)이었으며,1.0${\times}10^{-2 }$M 과산화수소를 이용해 15회 반복 측정한 결과, 상대표준편차는 1.87%이었다. 또한, 방해물질의 영향도 없는 것으로 나타났다. 효소전극의 감도는 19일 사용 후 50%로 감소하였다.

IN713LC-SCM440 이종재 마찰용접부의 부식특성에 미치는 pH의 영향 (The Effects of pH on the Corrosion Characteristics in Dissimilar Friction Welded Zone of IN713LC-SCM440)

  • 조상근;공유식;김영대
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.53-59
    • /
    • 2005
  • The effect of pH on the corrosion characteristics in the dissimilar friction welded zone of IN713LC-SCM440 in the loaded torsional stress was studied. The corrosion experiment was performed for 120 hours on the specimens with five steps of pH. The surface corrosion pattern of the SCM440 area showed global corrosion and narrow pitting, which was caused by galvanic corrosion between friction welded IN713LC and SCM440, but corrosion did not proceeded from the IN713LC area. The average relative electrode potential gradually tends to decrease with the elapse of the immersion time in the acidity area. The average corrosion current also gradually tend to decrease The corrosion rate showed a larger value when the average relative electrode potential was higher and the average relative current was lower. The corrosion rate showed a larger value when the average relative electrode potential was higher in the acidity area, and it showed large when the average relative electrode potential was lower in the alkalinity area.

혼합배열을 사용하는 시추공간 전기비저항 탐사 (The Crosshole Resistivity Method Using the Mixed Array)

  • 조인기;한성훈;김기주
    • 지구물리와물리탐사
    • /
    • 제5권4호
    • /
    • pp.250-256
    • /
    • 2002
  • 전기비저항 토모그래피는 지하의 전기비저항 분포를 영상화할 수 있는 매우 중요한 정밀 물리탐사법으로 지반조사 및 환경 오염대의 조사에 널리 사용되고 있다. 전기비저항 토모그래피 탐사의 경우 다양한 전극배열법이 사용될 수 있으며 각 배열법은 나름대로의 장단점을 가지고 있다. 예를 들어 단극배열의 경우에는 신호대 잡음비는 높으나 분해능이 벌어지며, 쌍극자배열의 경우에는 분해능은 높지만 신호대 잡음비가 너무 낮다. 단극-쌍극자 배열의 경우에는 중간정도의 분해능과 신호대 잡음비를 갖는다. 최근 개발된 변형된 단극-쌍극자 배열의 경우에는 단극-쌍극자 배열 수준의 신호대 잡음비와 분해능을 갖는다. 그러나 단극배열을 제외한 이들 전극배열법은 전류 및 전위 전극의 위치에 따라서는 겉보기 비저항이 발산할 수도 있다는 단점을 갖는다. 또한 단극배열의 경우에는 측정된 겉보기 비저항이 이상체의 전기비저항을 그대로 반영하지 못한다는 단점이 있다. 본 연구에서는 전류전극과 전위전극의 상대적인 위치에 따라 단극-쌍극자 배열과 변형된 단극-쌍극자 배열을 혼용하는 소위 혼합배열이라는 새로운 전극배열법을 제안하고자 한다. 이 새로운 전극배열법은 신호대 잡음비 및 분해능은 단극-쌍극자 배열의 수준을 유지하며, 측정 시추공상에서 겉보기 비저항이 발산하지 않는 특성을 갖는다. 또한 측정되는 겉보기 비저항은 항상 이상체의 전기비저항을 잘 반영한다.

Alga변성전극을 이용한 Cadmium(Ⅱ)의 양극벗김 전압-전류법적 정량 (Anodic Stripping Voltammetric Determination of Cadmium(Ⅱ) Using Alga-Modified Carbon Paste Electrodes)

  • 배준웅;최정은;장혜영
    • 대한화학회지
    • /
    • 제42권1호
    • /
    • pp.28-35
    • /
    • 1998
  • Alga와 같은 미생물은 중금속을 흡수한다. Alga(Anabaena)로 변성시킨 탄소반죽전극으로 Cd(Ⅱ)이온을 사전농축시켜서 Cd(Ⅱ)을 양극벗김 펄스차이 전압-전류법으로 정량하였다. Cd(Ⅱ)의 산화봉우리는 -0.75V vs. SCE.에서 나타났으며, 이 봉우리를 이용하여 Cd(Ⅱ) 정량의 최적조건을 조사하였다. 변성전극의 제작에 미치는 alga양의 영향과 Cd(Ⅱ)의 사전농축에 미치는 pH와 이온세기, 온도 및 사전농축시간에 대한 영향을 조사하였으며. 전극표면에 사전 농축시킨 Cd(Ⅱ)이온을 전해환원시키는 시간과 전위의 영향도 조사하였다. Cd(Ⅱ)을 정량하기 위한 검정선은 $1.0{\times}10^6\;M ~ 8.0{\times}10^6\;M$범위에서 직선성(상관계수는0.9978)이 성립하였고 검출한계는 $5.0{\times}10^{-7}\;M$이었다. $7.0{\times}10^{-6}\;M$ Cd(Ⅱ)용액에서 얻은 상대표준편차는 3.1%(n=6)이었다. Alga변성전극의 사용횟수는 0.1M HCl 용액으로 전극표면을 재생시킬 때에 10회까지 연속측정이 가능하였다.

  • PDF

양이온 교환막을 이용한 이산화탄소의 전기화학적 환원 (Electrochemical Reduction of Carbon Dioxide Using a Proton Exchange Membrane)

  • 김학윤;안상현;황승준;유성종;한종희;김지현;김수길;장종현
    • 전기화학회지
    • /
    • 제15권4호
    • /
    • pp.216-221
    • /
    • 2012
  • 전기화학적 환원을 통한 이산화탄소의 활용을 위한 노력은 오래 전부터 계속되어 왔다. 최근에는 액체연료 중 가격이 비싸고 그 활용도가 높은 포름산의 생성을 위한 연구가 많이 진행되고 있지만 실제 포름산을 생성하고 분석하는 과정에서 효율의 개선과 분석에 어려움이 따른다. 따라서 이산화탄소 환원을 이용한 포름산 생성에 필요한 시스템의 제조, 반응 조건의 개발 및 분석 방법의 정량화가 필요하다. 본 연구에서는 이산화탄소의 전기화학적 환원을 통한 포름산의 생성을 진행하고 생성된 포름산의 양을 분석하였다. 실험에 이용된 셀은 양이온 교환막을 사용하는 대용량의 회분형 셀을 이용하였으며 전위차계를 통하여 삼전극에서 전기화학 실험을 진행하였다. 전기화학 실험은 다양한 촉매 금속을 이용하여 선형 전위 주사법과 chronoamperometry를 통해 진행했으며 이 때 기준전극은 염화은 전극을 이용하였고 상대전극은 백금 전극을 사용하였다. 실험을 통해 생성된 포름산의 농도를 high performance liquid chromatography(HPLC)를 통하여 분석하여 시스템의 적정성과 분석 방법의 유효성을 검증하였다.

천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구 (A Study on Stress Corrosion Behaviors in Welded Zone of the API 5L-X65 Steel for Natural Gas Transmission)

  • 조상근;송한섭;공유식;김영대
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.401-407
    • /
    • 2004
  • This study is on the constant-current stress corrosion test related to the load stress in welded zone and non-welded zone of high tensile strength steel for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed global corrosion and narrow pitting, and the pitting was increased by increasing the load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel for natural gas transmission specimens was decreased suddenly, and the average relative electrode potential was higher and the average relative current was lower in welded zone than base metal. and the average relative electrode potential was decreased by increasing the load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone than base metal, and the corrosion rate was decreased by increasing the load stress.

  • PDF

$BCl_3/Ar$ 식각 플라즈마에서의 이온 에너지 분포 (Ion energy distributions in $BCl_3/Ar$ etching plasma)

  • 김관하;김창일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.54-56
    • /
    • 2005
  • QMS를 이용하여 chlorine based 유도결합 플라즈마 내 이온의 거동에 대한 분석을 하였다. 플라즈마 진단 가스로는 AT 가스에 $BCl_3$을 첨가하였으며 공정 압력을 변화하며 플라즈마 특성 변화를 분석하였다. 가스 혼합비에 따른 이온의 상대적인 밀도 변화에서 소량의 Ar가스의 첨가는 $BCl_3$ 가스의 이온화를 도와 $Cl^+$ 이온이 증가하는 현상을 보이며 Ar과 $BCl_3$의 이온화 에너지의 차이로 인해 $BCl_3$ 가스의 첨가비가 적을 수록, RF Power가 증가하며, 공정 압력이 낮올 수록 이중 피크 구조의 이온 에너지 분포를 확인 할 수 있었으며 이는 이온이 접지 전극에의 도달 시간과 평균 플라즈마 전위의 변화 때문이라고 사료된다.

  • PDF

수은 막전극을 이용한 수용액 중 과염소산이온의 전기화학적 환원 (Electrochemical Reduction of Perchlorate Using Mercury Film Electrode)

  • 명노승;김은영;지형우;금나래;이인숙;팽기정
    • 전기화학회지
    • /
    • 제19권3호
    • /
    • pp.95-100
    • /
    • 2016
  • 과염소산이온의 전기화학적 분해에 관한 연구가 진행되었다. 전기화학적 방법은 비교적 단순한 전처리 방법으로 가능하다. 하지만 전기화학적 방법은 과염소산이온이 분해되는 전압을 가해주었을 때 수소발생으로 인한 방해가 발생하기 때문에 사용하는 전극의 수소 과전압이 큰 것을 사용하여 수소발생을 줄이는 것이 요구되어 왔다. 본 연구에서는 수소 과전압이 큰 수은박막전극을 작업 전극으로 사용하였다. Ag / AgCl (sat. NaCl) 전극을 기준전극으로 사용하였으며 Pt를 상대전극으로 사용하였다. 수은박막전극은 순환 전압-전류법(Cyclic voltammetry, CV)으로 제작하였는데 과염소산 용액에서의 CV를 고려하여 수은박막전극의 안정성을 위해 10분 동안 전착시켰다. 과염소산이온의 환원전위는 CV 방법에 의해 설정되었고, 분해실험은 시간대 전류법 (Chronoamperometry, CA)로 시행하였다. 과염소산이온의 분해율 확인을 위해 이온 크로마토그래피(Ion chromatography, IC)를 사용하였다.

${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량 (Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine)

  • 정의덕;원미숙;박덕수;심윤보;최성낙
    • 대한화학회지
    • /
    • 제37권10호
    • /
    • pp.881-887
    • /
    • 1993
  • 코발트(II) 이온의 정량을 위해 ${\iota}$-sparteine(SP)으로 변성된 탄소 반죽 전극(carbon paste electrode : CPE)을 제작하였다. 수용액 중의 코발트 이온을 CPE에 처리시킨${\iota}$-sparteine과 반응시켜서 착화합물 상태로 전극표면에 석출시킨 후, 이 착물을 전압-전류법을 사용하여 정량하였다. 또한 변성된 CPE의 전극반응을 순환 전압-전류법을 사용하여 아세트산/아세트산염 완충용액에서 조사하였다. 한번 사용한 전극은 산용액으로 처리하여 5회 이상 재사용할 수 있었다. CPE에 흡착된 Co(II)-SP 착물의 산화환원 전위는 0.17V / 0.27V였으며 산화피이크는 0.17V의 환원피이크를 지나야 나타나는 피크이다. 이는 전극표면의 SP와 용액내의 Co(II)이온이 착물을 형성하여 흡착되고, 이 전극표면에 형성된 착물이 산화환원되어 나타나는 피이크이다. 펄스차이 전압-전류법을 사용할 경우 $2{\times}10^{-7}$M 농도까지 직선적으로 감응함을 알 수 있었으며, 그 때의 상대표준 편차는 ${\pm}$5.6%이었다. 이 경우 검출한계는 $1.0{\times}10^{-7}$M이었다. 리간드와 착물을 형성할 것으로 예상되는 여러 금속이온에 대한 방해작용을 조사하였다.

  • PDF

용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정 (Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes)

  • 강태영;김성배;오현준;한상현;차근식;남학현
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.466-473
    • /
    • 2000
  • 용매고분자막 상에 칼륨과 다양한 나트륨이온 선택성 중성 운반체의 착물형성상수(${\beta}_{MLn}$)를 고분자막형 광센서(optode)와 이온선택성 전극(ISE)을 이용하여 결정하였다. 수소이온선택성 발색물질(chromoionophore : ETH 5294)에 가장 널리 쓰이는 나트륨 이온선택성 물질들(4-tert-butylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecyl-methylmalonate 및 monensin methyl ester)을 첨가한 막과 첨가하지 않은 막으로 두 가지 다른 조성의 PVC 막을 제작하여, 일정 pH(0.05 M Tris-HCl, pH7.2)에서 알칼리금속 양이온(나트륨과 칼륨)의 농도 변화에 따른 광학적 감응을 측정하고, 또 일정한 알칼리금속 양이온 농도(0.1M)에서 pH변화에 따른 광학적 감응을 측정하였다. 또한 유사한 조성의 막을 각각 재래식 전극체에 장착하고 일정한 알칼리금속 양이온의 농도(0.1M)에서 pH 변화에 따른 전위치를 측정하였다. 양이온/수소이온의 활동도 비($a_{M^+}/a_{H^+}$)와 상대흡광도로 도시한 광센서 감응곡선과 수소이온농도에 따른 전위차 감응곡선으로부터 나트륨 이온선택성 리간드들의 착물형성상수를 결정하였다. 목적이온과 방해이온에 대한 착물형성상수들의 비로부터 얻어진 값은 실험적으로 얻어진 이온선택성 전극의 선택계수와 근접함을 확인하였다.

  • PDF