• Title/Summary/Keyword: 상대적 소화성능

Search Result 9, Processing Time 0.022 seconds

The Single- and Two-Phase Anaerobic Digestion of Food Waste Effluent (단상 및 이상혐기소화공정을 이용한 음폐수의 바이오에너지화)

  • HwangBo, Jun-Kwon;Seo, Jae-Gun;Yoon, Heui-Chul;Park, Hyeon-Gun;Lee, Bo-Won
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 2011
  • The anaerobic digestion of food waste effluent through single- and two-phase process was estimated and compared in this study. The treatment efficiencies for total solid(TS), volatile solid(VS), tCOD(total COD) and sCOD(soluble COD) were invariably higher in the single-phase process, which was accounted for by the fact that the treatment efficiency of organic wastes usually showed an inverse relationship with organic loading rate in the anaerobic digestion. In fact, the organic loading rate was lower for single-phase process. The concentration of tCOD were significantly lower in two-phase process but much more biogas was produced, compared to single-phase anaerobic digestion process, which might be explained partly by the relatively higher stability of two-phase process resulting from the separation of acid phase from methane phase.

A Study on the Measurement of Flame Extinguishing Concentration of Halon Alternatives by New Test Equipment (할론대체물질의 새로운 불꽃소화농도 측정장치에 관한 연구)

  • 김재덕;임종성;이윤우;이윤용
    • Fire Science and Engineering
    • /
    • v.8 no.1
    • /
    • pp.3-8
    • /
    • 1994
  • A new test system was established to measure the flame extinguishing concentration of Halon alternatives. The main characteristic of this system is to use the solid paraffin with a wick instead of liquid fuel, such as n-Heptane. Our results showed that the extinguishing concentration of compounds was lower than that of other existing data, but the trend was consistent with others. The flame extinguishing concentration of all tested compounds were not almost effected by gas flow velocity. The system produces good reliable data with a minimum error for measuring the flame extinguishing concentration. Therefore our new system can be utilized as a standard equipment to evaluate Halon alternatives.

  • PDF

Analysis of Fire Suppression Efficiency for Intermittent Water Spray Pattern by Fire Dynamics Simulator (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.216-220
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively lower than that of larger water droplet and the infiltration of water mist to the fire source is not effective. Contribution of evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist pattern is expected to improve the penetration force of water mist as well as the air expelling capability with the stratified spray characteristics. At this paper, we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis can support the basic concept to the development of the prototype of water mist nozzle.

Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process (음폐수 부하량에 따른 고온호기성 공정의 처리 양상)

  • Jang, Hyun Min;Choi, Suk Soon;Ha, Jeong Hyub;Park, Jong Moon
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • In this study, the feasibility of a single-stage thermophilic aerobic process for the treatment of high-strength food wastewater produced from the recycling process of food wastes was examined to substitute anaerobic digestion process. Also, the removal and stability of thermophilic aerobic process were assessed according to the changes of hydraulic retention times (HRTs) and organic loading rates (OLRs). When the OLR increased from 9.2 to $37.2kgCOD/m^3d$, a pH value in R1 (HRT : 5 d) significantly decreased to 5.0, due to the organic acid accumulation. On the other hand, the pH value in R2 (HRT : 10 d) was stable and R2 showed the high removal of COD, organic acid and lipid, even though the OLR increased from 4.6 to $18.6kgCOD/m^3d$. In R1, the COD loading rates for COD removal was suddenly dropped, as the COD loading rate increased from 18.6 to $28.4kgCOD/m^3d$. In contrast, R2 showed that the COD loading rates for COD removal increased with regard to increment in the loading rates of 3.61, 7.05, 9.43 and $12.2kgCOD/m^3d$, indicative of the high COD removal efficiency. Therefore, the results demonstrated that over 10-d HRT, the high concentration of raw food wastewater was efficiently treated in the single-stage thermophilic aerobic process.

Design and Application of Emergency Blockage System for Engine Part at IPPT and SQT (IPPT, SQT에서의 엔진부 비상정지 시스템 설계 및 운용)

  • 하성업;이중엽;정태규;한상엽
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.44-53
    • /
    • 2003
  • A vertical hot-firing test facility was established to carry out the IPPT(Integrated Propulsion Performance Test) and SQT(Stage Qualification Test) of KSR-III(Korea Sounding Rocket-III). The components for actual launcher were mostly used, hence these tests were carried out under the condition of relatively lower safety margin. To perform hot-firing tests with the maximum safety, an engine emergency blockage system was investigated and applied. An emergency blockage system using combustion chamber pressures and acceleration signals was set up to monitor ignition delay and fail, flame out, propellant feeding status, unstable combustion and excessive structural vibration. With such a system, the test safety could be secured by rapid judgement and follow-up measures, which made IPPT and SQT be safely completed.

A Survey on the Performance-based Design Status of Fire-fighting Facilities through the Whole Design Drawings and Specifications (설계도서 전수조사를 통한 소방시설분야 성능위주설계 현황조사)

  • Jeon, Eun-Goo;Bae, Young-Hoon;An, Sung-Ho;Hwang, Cheol-Hong;Hong, Won-Hwa;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.155-162
    • /
    • 2019
  • In Korea, the relevant laws and regulations for fire safety in buildings have been revised. Since 2011, Performance-based Design has been conducted for large-scale or high-rise buildings. However, the Korea's performance-based design is still at a level where life safety evaluation using fire and evacuation simulation tools is compared with existing methods. Although related studies have been conducted continuously for the mandatory performance-based design, the fact that it is relatively unsatisfactory for design and construction of fire-fighting facilities as it mainly focuses on administrative and institutional improvement measures or computer simulation. This study collected 91 performance-based design documents that were carried out nationwide at the initial stage of implementation until 2016 to analyze the status of performance-based design of fire-fighting facilities. As a result, fire-fighting facilities, except for fire extinguish system facilities, were not properly designed for performance. Furthermore, the designers found that if corresponding facilities or higher-level equipment with upgraded performance is additionally installed, the performance-based design fared well compared to the existing the prescriptive-based design.

A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems (지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구)

  • Baek, Sung-Kwon;Jeon, Joong-Kyu;An, Hyung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.546-549
    • /
    • 2007
  • 지열 냉난방 시스템의 설계는 냉난방 공간의 크기에 따라 필요한 부하를 계산하여 설계하게된 다. 설계 부하를 충분히 소화할 수 있는 지열교환기의 길이와 보어홀의 깊이 및 개수는 지반의 열적 특성에 크게 좌우된다. 열전도율이 큰 지반일수록 지열교환기 내의 열 흡수 및 소산이 효과적으로 이루어져 지열교환기의 길이도 상대적으로 짧아질 수 있다. 즉, 효율적이고 정확한 설계를 하기 위해서는 지반, 암반 및 지중열교환기의 물리적 특성에 따른 열적 특성을 설계자는 미리 숙지하여야 한다. 현재 국내에서 수직 밀폐형 지중열교환기의 그라우트로 벤토나이트를 가장 많이 사용하고 있으나, 해외의 경우 지중 조건에 따라 시멘트 또는 벤토나이트를 적절히 선택하여 시공하고 있다. 이는 벤토나이트의 특성상 적용 조건이 제약을 받기 때문이며, 특히 지하수가 존재하지 않을 경우 사용이 사실상 불가능하다. 국내에서 이에 대한 충분한 연구는 아직 이루어지지 않았으며, 시멘트 그라우트를 사용하기 위한 물리적, 열적 특성에 대한 연구가 필요한 시점이라 판단하여 본 연구를 수행하였다. 시멘트 그라우트의 경우 수화반응이 일어나는 초기의 건조수축을 최소화하는 배합비로 물성을 구성하였으며, 벤토나이트는 일반 현장 시공 비율을 사용하였다. 열전도율은 첫째 실내 시험으로 시멘트 그라우트에 대한 열판시험법과 벤토나이트 그라우트에 대한 탐침시험법으로 수행하여 구하였으며, 두 번째 방법인 현장 시공으로 직접 현장열응답시험을 수행하여 그라우트 간의 열적 특성을 비교하였다. 또한 기존 시멘트그라우트의 열적 특성을 개량한 코오롱건설에서 개발한 시멘트 그라우트에 대한 열적 거동도 기존 타 그라우트의 열적 거동과 비교하였으며, 개발 제품의 성능이 상당히 우수함을 알 수 있었다.

  • PDF

Experimental Study on Hydraulic Characteristics and Vorticity Interactions of Floating Breakwaters (부유식방파제의 수리특성 및 와 상호작용에 관한 실험적 연구)

  • Yoon, Jae Seon;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.55-55
    • /
    • 2011
  • 연안 및 해안공학의 발달과 더불어 부유식방파제의 기능적 효율성이 중요시 되고 있다. 흔히 사용되어오던 착저식방파제는 설치에 많은 시간과 경비가 소요되고 환경 및 생태계에 많은 변화를 줄 수 있으며, 설치 예정지의 수리학적 특성 등의 여건에 많은 제약을 받는 단점이 있다. 부유식방파제는 일본 등의 선진국을 중심으로 활용이 잦아지고 있는 방파제로서 수면 위에 설치되기 때문에 수중 생태계에 미치는 영향이 적은 친환경방파제이다. 또한 기존에 시공된 중력식방파제와는 달리 수심에 제한을 덜 받고, 공사기간이 짧기 때문에 경제적이다. 실제 시공사례로는 2007년 마산 원전항에 완공된 부유식방파제가 대표적이며, 지금까지도 부유식방파제에 대한 여러 연구자들의 관심이 증가하고 있는 추세이다. 방파제뿐만 아니라 우리나라처럼 국토의 면적이 작은 지역에서 증가하는 해상물동량을 소화하기 위해서 부유식방파제 등을 이용한 항만의 시공이 필요한 실정이다. 이러한 부유식방파제의 분석적인 측면에 있어서 수치해석은 파랑과 구조물의 상호작용을 해석하는 데 한계가 있으며, 부유식방파제 단면형상을 정확하게 재현할 수 없으므로, 수리모형실험을 통한 부유식방파제의 연구가 필요할 것으로 판단된다. 최근 기술의 발달로 인한 유동장 해명이 가능해 졌으며, PIV(Particle image velocimetry) 및 LDV시스템은 다양한 분야에서 응용되고 있다. 특히, LDV시스템은 측정하려는 한 지점에 대하여 레이저 빔을 단면(Cross-section)으로 만들고 입자의 산란광을 후방산란(Back scatter)으로 받아서 도플러 효과를 이용, 속도에 대한 주파수를 획득하며, 유속을 측정하는 장비로 매우 높은 정확도와 비접촉식 이라는 장점을 가지고 있다. 또한, PIV 시스템에 비하여 측정시간이 오래 걸리는 반면 데이터를 가공하지 않고 활용할 만큼 높은 정확성을 가지고 있다. 본 연구에서는 수리모형실험을 통하여 단독형, 2열형 및 3열형 부유식방파제의 형상, 흘수 및 거리를 변화시키며 유동장을 수집하였으며, 방파성능에 따른 와의 생성 및 소멸시점에서의 파랑변형과의 관계를 분석하였다. 방파제의 형상과 흘수를 달리하여 수리모형실험을 수행하였으며, 와류의 상관관계를 분석하였다. 또한, 연직 2차원 Navier-Stokes 방정식 모형을 이용하여 수치모형실험을 수행하였으며, 수치모형실험 결과와 수리모형실험 결과를 비교 분석하였다. 후방방파제에서 발생되는 파랑은 입사파의 주기가 길어질수록 상대적으로 커지는 현상을 보였으며, 흘수심이 깊어질수록 전방방파제 입사 면에서 자유 수면이 높게 관측되는 결과를 보였다. 또한, 비교적 장주기파랑에 해당하는 입사파랑의 경우 전달파고비 산정에 있어서 설계기준인 0.5를 대다수 초과하는 반면, 3열형 구조에서는 대부분이 0.5이하로 상당히 높은 방파성능 결과를 나타내었다.

  • PDF

Effects of the Glycoprotein Isolated from Pteridium aquilinum on the Immune Function of Mice (고사리 단백다당(Pteridium aquilinum Glycoprotein, PAG)이 마우스 면역활성에 미치는 영향)

  • Park, Hyeon-Ae;Kweon, Mee-Hyang;Han, Hyung-Mee;Sung, Ha-Chin;Yang, Han-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.976-982
    • /
    • 1998
  • The effects of the glycoprotein (PAG) isolated from Pteridium aquilinum on the immune function was examined in mice. PAG was intraperitoneally administered into BALB/C mice for 14 days and the antibody forming ability to hen egg lysozyme (HEL) and the blastogenic responses of splenocytes were measured. PAG treatment significantly increased antibody formation to HEL in a dose-dependent manner. Blatogenesis of splenocytes in response to lipopolysaccharide (LPS, B-cell specific mitogen) or phytohemagglutinin (PHA, T-cell specific mitogen) was also increased after treatment with PAG, indicating that the PAG increases both humoral and cellular immunities. To examine whether the immune function of PAG was via a direct effect on the lymphocytes, splenocytes were isolated from BALB/C mice, exposed to various concentrations of PAG in vitro and the blastogenic responses were measured. In vitro exposure to PAG significantly increased blastogenesis of splenocytes to LPS up to $500{\;}{\mu}g/kg$, whereas the blastogenic response to PHA was not altered by PAG treatment. To identify the fraction responsible for the increase in the immune function, the effect of periodate digest, pronase digest or purified polysaccharide on the antibody production to HEL was examined. Crude protein fraction of PAG significantly increased the antibody formation to HEL. On the other hand, both crude and purified polysaccharide fractions did not have any effects on the antibody production ability. These data indicated that 1) PAG increased both humoral and cellular immune functions, 2) the increase in humoral immunity was probably via a direct action of PAG on lymphocytes and 3) the protein portion of PAG was responsible for the increase in humoral immunity.

  • PDF