• Title/Summary/Keyword: 상대속도 차

Search Result 76, Processing Time 0.023 seconds

Safety Improvement of Installation of "Hi-pass" System at Expressway Toll Gate (교통상충기법을 이용한 고속도로 하이패스차로 안전성 개선에 관한 연구 (서울외곽순환고속도로 본선영업소를 중심으로))

  • Yu, Bong-Seok;Lee, Su-Beom;Park, Wan-Yong;Park, Jun-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.4
    • /
    • pp.7-18
    • /
    • 2010
  • This study analyzed the relative vehicle speed and vehicle deceleration time caused by traffic conflicts using vehicle speed data at expressway toll gates and traffic conflict occurrence data. According to the analysis, the greater the relative vehicle speed is at the toll gate, the more sudden vehicle deceleration occurs due to traffic conflicts. In particular, a comparison study of cases in similar operating conditions presents a finding that usage of lanes influences traffic conflict occurrences as well as relative vehicle speed. With this finding, the study further conducted a quantitative analysis of the accident rates in relation to the relative vehicle speed between vehicles using a "Hi-Pass" lane and a regular lane at the toll gate. It indicates that when the relative vehicle speed is greater, the accident rate is higher due to sudden vehicle deceleration and shorter deceleration time. Furthermore, when the expressway entrance/exit point is closely located to a toll gate and the relative vehicle speed is great, a analysis at a traffic conflict shows a low value.

Safety Improvement of Centrally Installed "Hi-pass" Lane of Express Highway (고속도로 중앙하이패스차로 안전성 개선에 관한 연구 - 서울외곽순환고속도로 본선영업소를 중심으로 -)

  • Yoo, Bong-Seok;Lee, Soo-Beom;Park, Wan-Yong;Do, Hyun-Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.1-10
    • /
    • 2010
  • Safety improvement has been a continuous challenge, especially at toll gate of express highway where traffic conflict often occurs due to frequent lane change by drivers of "Hi-pass" lane and regular "TCS" lane. As a part of research on safety at toll gate, this study videotaped traffic conflict data between vehicles using centrally located "Hi-pass" lane and regular "TCS" lane and analyzed accident risk. According to the correlation analysis of vehicle speed, relative vehicle speed, and sudden vehicle deceleration rate due to traffic conflict, when the relative vehicle speed between centrally located "Hi-pass" lane and regular "TCS" lane increases, sudden vehicle deceleration rate also increases. One of the findings is that centrally located "Hi-pass" lane at toll gate shows different location for traffic conflict, and frequency of traffic conflict and the relative vehicle speed was also different based on vehicle lane use. TA (Time to Accident) analysis shows that accident rate is high at toll gate where Hipass lane is installed in center lane, when the occurrence of sudden vehicle deceleration and deceleration time of vehicles rise for vehicles on "Hi-pass" lane. Furthermore, if the expressway entrance/exit point is closely located to toll gate, TA showed a low value. Thus, it is necessary to reduce the relative vehicle speed in order to improve safety. The Study presents reduction of the relevant vehicular speed and prevention of accidents at the centrally installed "Hi-pass" lane as an important strategy for safety improvement at toll gate.

Development of Cut-in Lane Changing Model Based on Observed Driver's Behavior in Uninterrupted Traffic Flow (연속교통류에서의 끼어들기 행태 분석 및 모형 개발)

  • Kim, Kyung-Hee;Chang, Myung-Soon;Kim, Jin-Tae;Kim, Eung-Cheol
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.6
    • /
    • pp.145-157
    • /
    • 2004
  • Microscopic freeway simulation models project the uncertain values of performance measures for subject traffic conditions by explaining drivers' driving behavior with lane changing and car-following models. However, the existing lane changing models are limited to gap acceptance oriented passive behavior of drivers and not able to capture more-or-less aggressive driving behavior(e.g. cut-in lane changing) ordinarily obseved in field. This paper suggests the definition of cut-inlane changing and presents its characteristics based on the findings from two different freeway on- and off-ramp sections. In addition, this paper proposes a new lane changing model capable of handling both passive and active drivers' driving behavior for better performance of simulations. The proposed lane changing model was tested with Hanyang Simulatin (HYTSIM), a microscopic freeway simulation program developed for this study. The HYTSIM simulation results reflecting the performance of the proposed lane changing model were compared against the field data. The test results showed that the distribution of gaps collected when vehicles change lanes were statistically identical to the field data at 95% confidence level.

PmP파의 주행시간을 이용한 한반도 남부지역의 지각두께 연구

  • 박종찬;함인경;김우한;최광선
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.21-21
    • /
    • 2003
  • 국내 지진관측망에 기록된 지진기록으로부터 관측한 PmP파의 주행시간을 이용하여 한반도 남부지역에서의 지각두께를 추정한다. 모호면으로부터 반사된 파형인 PmP파의 주행시간은 지각두께와 속도구조에 의존한다. 만약 실제 지각의 평균속도와 모델속도 사이의 차이가 작다고 가정하면, 계산한 주행시간과 실제 지진기록으로부터 관측한 주행시간의 상대적인 차이는 반사점에서 지각의 상대적인 두께차이에만 의존한다. 따라서 PmP파가 반사된 지점에서의 지각두께는 주행시간의 상대적인 차이가 표본추출간격보다 작은 값을 가질 때까지 지각두께를 변화시켜줌으로서 계산되어진다. 계산결과 한반도 남부지역에서의 지각두께는 지리산 부근 지역이 가장 두껍고 경상분지 지역이 가장 얇으며 호남지역은 중간 두께를 나타낸다.

  • PDF

Effect of Vapor Pressure Deficit on the Evapotranspiration Rate and Graft-taking of Grafted Seedling Population under Artificial Lighting (인공광하에서 접목묘 개체군의 증발산속도와 활착에 미치는 포차의 영향)

  • Yong Hyeon Kim;Chul Soo Kim;Ji Won Lee;Sang Gyu Lee
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.232-236
    • /
    • 2001
  • Four air temperature levels of 23, 25, 27 and 29$^{\circ}C$, three humidity levels of 85, 90 and 95% R.H. at photosynthetic photon flux (PPF) of 50 $\mu$mol.m$^{-2}$ .s$^{-1}$ were provided to investigate the effect of vapor pressure deficit on the evapotranspiration rate (EVTR) and graft-taking of watermelon grafted seed-increase. Thus EVTR of grafted seedlings increased with increasing air temperature at high humidity of 95%R.H. At relatively low humidity of 85% R.H., grafted seedlings showed a high EVTR and some wilting of scions was observed at this condition. This result would be ascribed to the low supply of water to vascular bundles according to the insufficient joining of scions and rootstocks. Differences in EVTR between 90% R.H. and 95% R.H. were not observed. Grafted seedlings showed high graft-taking at high relative humidity. Relative humidity had highly influenced to the graft-taking as compared to the air temperature. Graft-taking increased with decreasing vapor pressure deficit. Graft-taking greater than 90% was found at vapor pressure deficit less than 0.4kPa which could be obtained at humidity higher than 90% R.H. Therefore it is required to control the humidity higher than 90% R.H. for suppressing EVTR of grafted seedlings and preventing some wilting of scoins and thus enhancing the graft-taking of grafted seedlings.

  • PDF

A Pilot Study on Installation Criteria of Speed Change Lanes according to the Implementation of Safety Speed "5030" in the Urban Area (도심내 안전속도 "5030"시행에 따른 변속차로 설치기준에 관한 기초연구)

  • Oh, Seok-Jin;Ha, Tae-Jun;Jin, Tae-Hee;Shin, Kwang-Min;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • The speed change lane is installed at the point where the roads are connected on the urban roads, reducing the relative speed to facilitate traffic communication. However, in the case of the speed limit of 30 km/h in accordance with the implementation of the safe speed "5030" in the city, the standard is ambiguous, and there are criticisms about the installation of the transmission lane. This study conducted a pilot study on the traffic patterns of the speed change lanes, focusing on the section where the safe speed "5030" policy was scheduled to be implemented after theoretical consideration of the speed change lanes. After on-site investigation, as a result of analyzing the traffic pattern according to the travel speed of the main road according to road conditions and traffic conditions, the effectiveness of the speed change lane according to the safety speed "5030" was analyzed. In this study, the installation criteria for speed change lane by speed were presented. The criteria is that "speed change lanes should not be installed when the speed limit is 30 km/h, and speed change lanes should be installed when the speed limit is 50 km/h." The criteria will be considered as a reference when establishing engineering standards for connection of other facilities in urban areas in the future. It is expected that unnecessary restrictions on individuals' exercise of private property rights will be minimized, smooth traffic flow and secure safety by the installation of speed change lanes and expansion of turning radius.

Effects of Air Current Speed on the Microclimates of the Plug Stand under Artificial Light (기류속도가 인공광하에서 공정육묘 개체군의 미기상에 미치는 영향)

  • 김용현;고재풍수
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.160-166
    • /
    • 1996
  • Objective of this study was to investigate the effects of all current speed on the microclimates above and inside the plug stand under artificial light. Maximum air temperature appeared near the top of the plug stand. Difference in air temperature inside the plug stand increased with the decreasing air current speed. Difference in relative humidity(DRH) to the relative humidity at the Inlet of the main air flow conditioner Inside and above the plug stand decreased with the increasing air current speed. Relative humidity inside the plug stand was 10-15% higher than that above the plug stand. DRH inside a stand of plug at air current speed of 0.3m s$^{-1}$ was about two times as many as that at air current speed of 0.9 m s$^{-1}$ . DRH inside the plug stand was 2.8-6.5% higher at LAI of 2.6 than that at LAI of 0.5. Gradient for the vapour pressure deficit was distinctly appeared at the low air current speed. Direction of vapour pressure flux is from the medium surface upwards. Difference in vapour pressure(DVPD) to the vapour pressure deficit at the inlet of the main air flow conditioner inside and above the plug stand decreased with the increasing height above the medium surface. DVPD inside the plug stand was 0.3-0.4㎪ higher at air current speed of 0.9m s$^{-1}$ than that at air current speed of 0.3m s$^{-1}$ . Results for the effects of air current speed on the relative humidity and vapour pressure deficit indicated that the microclimates above and inside the plug stand at the rear region in plug trays were slightly unfavorable compared to those at middle region.

  • PDF

A Study on Surface Drift Velocity in Water Waves (파랑에 의한 수표면 부유속도에 관한 연구)

  • 김태인;최한규;권혁재
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.4
    • /
    • pp.329-339
    • /
    • 1995
  • To clarify the surface drift velocity in gravity waves. experimental data measured in a two-dimensional wave flume were compared with theoretical values predicted by the Stokes 2nd- and 5th- order theories as well as by the conduction solution or Longuet-Hinggins (1953). Relative water depth and wave height ranged 0.040.13. For a closed flume condition, Stokes 2nd-order theory gives lower values than the experimental data, and the differences increase as both relative water depth and wave height increase. Based on the observed data of the surface drift velocities, a modified Parabolic model of the return current velocity Profile has been suggested, which is Proved to fit better to the existing experimental data of mass transport velocity profiles in a closed wave flume than the models of Longuet-Hinggins (1953) and Stokes wave theories do.

  • PDF

Critical Speed Analysis of a 75 Ton Class Liquid Rocket Engine Turbopump due to Load Characteristics (75톤급 액체로켓엔진 터보펌프의 하중 특성에 따른 임계속도 해석)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Hong, Soon-Sam;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.22-29
    • /
    • 2011
  • Critical speed of high thrust liquid rocket engine turbopump is obtained through a rotordynamic analysis and a unloaded turbopump test is peformed for validation of the numerical model. The first critical speed predicted by the numerical analysis is correlated well with the test result for the bearing unloaded rotor condition only considering mass unbalance load. Using the previous rotordynamic model, critical speed variation is estimated as a function of varied bearing stiffness due to pump and turbine radial loads with relative angle difference. From the numerical analysis, it is found that the relative angle difference of pump and turbine radial loads greatly affects the critical speed. However, additional axial load reduces the effect derived from the relative angle difference of radial loads.

  • PDF

Critical Speed Analysis of a 75 Ton Class Liquid Rocket Engine Turbopump due to Load Characteristics (75톤급 액체로켓엔진 터보펌프의 하중 특성에 따른 임계속도 해석)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Hong, Soon-Sam;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.42-49
    • /
    • 2012
  • Critical speed of high thrust liquid rocket engine turbopump is obtained through a rotordynamic analysis and a unloaded turbopump test is peformed for validation of the numerical model. The first critical speed predicted by the numerical analysis is correlated well with the test result for the bearing unloaded rotor condition only considering mass unbalance load. Using the previous rotordynamic model, critical speed variation is estimated as a function of varied bearing stiffness due to pump and turbine radial loads with relative angle difference. From the numerical analysis, it is found that the relative angle difference of pump and turbine radial loads greatly affects the critical speed. However, additional axial load reduces the effect derived from the relative angle difference of radial loads.