• Title/Summary/Keyword: 상관 영역

Search Result 2,361, Processing Time 0.034 seconds

A Validation Study for the Practical Use of Screening Scale for Potential Drug-use Adolescents(SPDA) (청소년 약물사용 잠재군 선별척도(SPDA) 활용을 위한 타당화 연구)

  • Lee, Ki-Young;Kim, Young-Mi;Im, Hyuk;Park, Mi-Jin;Park, Sun-Hee
    • Korean Journal of Social Welfare
    • /
    • v.57 no.3
    • /
    • pp.305-335
    • /
    • 2005
  • This paper is a result from validation study for SPDA(A Screening Scale For Potential Drug-use Adolescents) created in 2003 and newly developed during 2004. SPDA aims to screen adolescents in their early stage of drug-use and to help practitioners make a preventive approach for the adolescents. 4307 junior and senior high school students were selected as primary research subjects by stratified and quota sampling methods. 305 adolescents on probation were also selected as a comparison group and asked to answer the same questionnaire. Reliability for SPDA recorded 0.914, which proved to be better than previous year's (0.898). Exploratory and confirmatory factor analyses to test construct validity proved that SPDA could be divided into 7 factors and that each factor structure of SPDA could be a proper measurement model with high level of fitness and factor loadings. Discriminant analysis to test predictive validity confirmed that SPDA could classify the adolescents excellently by the frequency of drug-use, with hit ratio of 86.6 percent(78.8% and 87.4% for junior and senior high school students respectively). For concurrent validity test, Hare Home Self-Esteem Scale, Hare School Self-Esteem, Zuckerman-Kuhlman Sensation-seeking Scale were employed to find correlation with SPDA and all the three scales had significant Pearson correlation coefficients with SPDA. Known-groups validity test indicated that SPDA had an adequate power to classify out adolescents on probation from those in schooling, with a hit ratio of 71.8 percent. Cut-off point to detect adolescents with high risk of substance use was 77, which indicated approximately T score, 55 (0.5 SD), satisfying sensitivity, specificity, and efficiency criteria.

  • PDF

Standards of Protection in Investment Arbitration for Upcoming Climate Change Cases (기후변화 관련 사건에 적용되는 국제투자중재의 투자자 보호 기준)

  • Kim, Dae-Jung
    • Journal of Arbitration Studies
    • /
    • v.24 no.2
    • /
    • pp.33-52
    • /
    • 2014
  • Although climate change is a global scale question, some concerns have been raised that principles of investment arbitration may not adequately address the domestic implementation of climate change measures. A recent ICSID investment arbitration of Vattenfall v. Germany with regard to the investor's alleged damages from the phase-out of nuclear plants is a salient climate change case. The 2005 Kyoto Protocol was made to reduce greenhouse gas emissions and it provides a number of flexible mechanisms such as Joint Implementation (JI) and Clean Development Mechanism (CDM). Implementation of the Kyoto Protocol allows dispute settlement through investor-state arbitration. Any initiation of stricter emission standards can violate the prohibition on expropriations in investment agreements, regardless of the measures created to reduce greenhouse gas emissions. The effect-based expropriation doctrine can charge changes to existing emission standards as interference with the use of property that goes against the legitimate expectation of a foreign investor. In regulatory chill, threat of investor claims against the host state may preclude the strengthening of climate change measures. Stabilization clauses also have a freezing effect on the hosting state's regulation and a new law applicable to the investment. In the fair and equitable standard, basic expectations of investors when entering into earlier carbon-intensive operations can be affected by a regulation seeking to change into a low-carbon approach. As seen in the Methanex tribunal, a non-discriminatory and public purpose of environmental protection measures should be considered as non-expropriation in the arbitral tribunal unless its decision would intentionally impede a foreign investor's investment.

  • PDF

Analysis of source localization of P300 in college students with schizotypal traits (조현형 인격 성향을 가진 대학생의 P300 국소화 분석)

  • Jang, Kyoung-Mi;Kim, Bo-Mi;Na, Eun-Chan;An, Eun-Ji;Kim, Myung-Sun
    • Korean Journal of Cognitive Science
    • /
    • v.28 no.1
    • /
    • pp.1-26
    • /
    • 2017
  • This study investigated the cortical generators of P300 in college students with schizotypal traits by using an auditory oddball paradigm, event-related potentials (ERPs) and standardized low resolution brain electromagnetic tomography (sLORETA) model. We also investigated the relationship between the current density of P300 and the clinical symptoms of schizophrenia. Based on the scores of Schizotypal Personality Questionnaire(SPQ), schizotypal trait (n=37) and control (n=42) groups were selected. For the measurement of P300, an auditory oddball paradigm, in which frequent standard tones (1000Hz) and rare target tones (1500Hz) were presented randomly, was used. Participants were required to count the number of the target tones during the task and report this at the end of the experiment. The two groups did not differ significantly in the accuracy of the oddball task. The schizotypal trait group showed significantly smaller P300 amplitudes than control group. In terms of source localization, both groups showed the P300 current density over bilateral frontal, parietal, temporal and occipital lobes. However, the schizotypal trait group showed significantly reduced activations in the left superior temporal gyrus and the right middle temporal gyrus, but increased activations in both left inferior frontal gyrus and right superior frontal gyrus compared to the control group. Furthermore, a negative correlation between the current density of the right superior frontal gyrus and SPQ disorganization score was found in the schizotypal trait group. These findings indicate that the individuals with schizotypal traits have dysfunctions of frontal and temporal areas, which are known to be the source of P300, as observed in patients with schizophrenia. In addition, the present results indicate that the disorganization score, rather than total score, of the SPQ is useful in predicting the risk of future schizophrenia.

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

Comparative Evaluation for the Effect of SUV's Due to a Residual Radio-activity Location Inside Vascular Insert Devices During PET/CT Scans (PET/CT 검사 시 혈관삽입기구 내 잔여 방사능 위치에 따른 표준섭취계수의 영향 비교 평가)

  • Sim, Woo Yong;Kim, Jung Yul;Cho, Suk Won;Oh, Shin Hyun;Lim, Han Sang;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.94-97
    • /
    • 2014
  • Purpose: Standardized uptake value (SUV) is a simple semi-quantitative method that can measure the ratio of the tissue radioactivity between the tumor and normal. SUV is commonly used in PET/CT, however, SUV is affected by various factor. The purpose of this study was to evaluate the impact of the residual activity on SUV depending on the location of catheter insertion device post injection. Materials and Methods: NEMA IEC Body Phantom was imaged using a Discovery 600 PET scanner. In 22 mm diameter sphere, the different activity of $^{18}F-FDG$ (7.4, 14.8, 22.2, 29.6, 37, 55.5 MBq) was filled and background was filled with $^{18}F-FDG$ (5.7 kBq/mL). We scaned the phantom on the assumption that the radioactivity in sphere was residual activity in insertion device. Simulation of PET was divided into three groups based on the location of sphere in Scan FOV (SFOV); inclusion, 1/2 inclusion and exclusion group. Results: Among three groups, the group of excluded sphere showed the highest SUV regardless of the amount of $^{18}F-FDG$ activity. In case of 7.4 MBq, average SUV of inclusion group, 1/2 inclusion and exclusion group was 0.780, 0.840 and 0.896 respectively. However, average SUV of 55.5 MBq showed 0.372, 0.460 and 0.508 with same order. Depend on residual radioactivity in the sphere and position of sphere, the SUV was different minimum of 10.4%, maximum of 62.8%. Conclusion: This study showed that SUV is underestimated as the residual radio-activity is increased. In addition, SUV was a changed according to the position of residual radio-activity. And among the position, exclusion group showed the difference of SUV was lowest. If we measure the residual radio-activity of inserting devices and radio-activity from extra-vasation in the patients, it seems to be more useful in clinical field.

  • PDF

X-ray Absorption Spectroscopy Study on Surface Interaction of Arsenite onto Two-Line Ferrihydrite at pHs 4 and 10 (pH 4와 10에서의 3가 비소와 Two-Line Ferrihydrite의 표면반응에 대한 X선 흡수 분광 연구)

  • Lee, Woo-Chun;Choi, Sun-Hee;Cho, Hyen-Goo;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.73-82
    • /
    • 2011
  • X-ray absorption spectroscopy (XAS) study was conducted using arsenite-sorbed two-line ferrihydrite to investigate the mechanism of surface interactions between two-line ferrihydrite and As(III) (arsenite) which are ubiquitous in nature. The two-line ferrihydrite used was synthesized in the laboratory and the study was undertaken at pHs 4 and 10 to compare the difference in mechanisms of surface interaction between acidic and alkaline environments. The effect of arsenite-adsorbed concentrations on surface complexation was investigated at each pH condition as well. From the results of XAS analyses, the structural parameters of arsenite in the EXAFS revealed that the coordination number and distanceof As-O were 3.1~3.3 and 1.74~1.79 ${\AA}$, respectively, which indicate that the unit structure of arsenite complex formed on the surface of two-line ferrihydrite is $AsO_3$. The dominant structures of As(III)-Fe complex were examined to be bidentate binuclear comer-sharing ($^2C$) and the mixture of bidentate mononuclear edge sharing ($^2E$) and $^2C$ appeared as well. At pH 4, arsenite complex showed different structures on the surface of two-line ferrihydrite, depending on the adsorbed concentrations. At pH 10, on the contrary, the surface structures of arsenite complexes were interpreted to be almost identical, irrespective of the adsorbed concentrations of arsenite. Consequently, this microscopic XAS results support the results of macroscopic adsorption experiments in which the surface interaction between arsenite and two-line ferrihydrite is significantly influenced by pH conditions as well as arsenite concentrations.

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

A Clinical Study of Hearing Disturbance and Middle Ear Pathology in Chronic Otitis Media (만성중이염의 교실내 병변과 청력에 관한 임상적 연구)

  • 박동석;전재기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.4.4-5
    • /
    • 1979
  • The degree of hearing impairment of chronic otitis media will indicate the nature and severity of middle ear pathology especially condition of ossicular chain, size of ear drum perforation and location of granulation tissue in the middle ear cavity. The subjects were 189 ears of tympanoplasty for chronic otitis media and divided into four groups as follows: Normal ossicular chain with only ear drum perforation (group I), normal ossicular chain with granulation tissue only around the ossicles regardless of any other region (group II), ossicular ankylosis or fixation of handle of malleus to promontory with or without granulation tissue around the ossicle (group III) and ossicular interruption by partial or complete destruction(groupf IV). The results were concluded as follows: 1) The average hearing threshold of chronic otitis media was 44.6 dB and hearing threshold was closely related to the condition of ossicular chain. Hearing threshold became greater in order of normal ossicular chain, ankylosis and interruption. 2) The average hearing threshold of ossicular interrupted group was 49.1 dB and it was greater in the cases of total destruction than that of partial destruction. 3) The hearing loss in the cases of normal ossicular chain with only tympanic membrane perforation was within 45 dB and this level was presumed to represent normal ossicular function. The degree of hearing loss was in proportion to the size of ear drum perforation and when over 45 dB, other middle ear pathology was suggested. 4) In the cases of small ear drum perforation with normal ossicular function, the hearing threshold was within 30 dB. 5) In the type of audiogram, flat type was 30.2% and ascending type 35.4%. Descending type was more frequent in the cases of normal ossicular mobility with granulation tissue around the ossicle and flat type was observed frequently in the cases of ossicular ankylosis. 6) Carhart's notch was seen in 14 cases (7.4%) and observed mainly in ossicular ankylosis. 7) There was no relation between hearing threshold and histopathological type of granulation tissue in chronic otitis media. However the degree of hearing impairment was related to the location of granulation tissue in the middle ear cavity. 8) Authors recognized the granulation tissue compensated the function of interrupted ossicular chain.

  • PDF