• Title/Summary/Keyword: 삽입 금속

Search Result 338, Processing Time 0.023 seconds

Recycling Bone Autotransplantation with Extracorporeal Heat-Treatment for Malignant Bone Tumors of Pelvis (골반골의 악성 골종양의 재건술에서 체외 열처리를 이용한 재활용 자가골 이식술 및 인공 관절 치환술을 시행한 3례 보고)

  • Kim, Sae-Hoon;Lee, Sang-Hoon;Cho, Hwan-Sung;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.115-123
    • /
    • 2003
  • Study Design: A retrospective clinical and radiographic review. Objectives: The purpose of this study was to suggest recycling bone autotransplantation with extracorporeal heat-treatment as one of favorable reconstruction method for malignant bone tumors of pelvis through 3 cases. Summary of Literature Review: There are many biologic and nonbiologic reconstruction method in pelvic reconstruction. Cases: Case 1- A 20-year-old women had chief complaint of right hip and thigh pain started 3 months ago and done curettage and bone cementing at right ilium at other hospital. She had impression of malignant bone tumor and undergone postoperative radiation therapy for 6 cycles. After that she was referred to our hospital and undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal heat-treatment at 132 degree celsius for 2 minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed well-differentiated osteosarcoma on postoperative pathology. Neither adjuvant nor neoadjuvant chemotherapy were done. Case 2- A 56-year-old women who suffered right thigh pain for 3 months was detected radiologic abnormality at right pelvis. After incisional biopsy, osteosarcoma was diagnosed. We had undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed high-grade osteosacoma which was fibroblastic type on postoperative pathology. Adjuvant chemotherapy (HDMTX, ADR, CDDP) was done immediate after wound healing was completed. Case 3- A 46-year-old women was incidently found mass at left ilium which was suspected chondrosarcoma. We had undergone wide excision of left ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (Protek$^{(R)}$). There was no evidence of distant metastasis and revealed chondrosarcoma which was graded II/III on postoperative pathology. Results: Oncologic and functional outcome at final follow-up were for case 1, final follow-up time was 7 years, is no evidence of disease and functional score is 53% according to Ennecking et al. During follow-up, evidence of radiologic union was at about 1 and 6 months after operation. The case had breakage of pelvic reconstruction plate and some resorption of autotransplated bone, but no symptom present. For case 2, final follow-up was 3 years and 6 months, is no evidence of disease and functional score is 60%. For case 3, final follow-up was 7 months, no evidence of disease and functional score is 63% which is improving state. Discussion: 3 cases which were undergone recycling bone autotransplantation with extracorporeal heat-treatment and total hip replacement arthroplasty had relatively successful oncologic and functional outcome. Taking account that difficulty in using allograft in Korea this method is thoght to be one of the useful way to reconstruct pelvis after resection of primary malignant bone tumor of the pelvis.

  • PDF

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane (요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구)

  • Jung, Da-Bin;Lee, Hae-Kag;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.927-933
    • /
    • 2021
  • The purpose of this study was to compare and analyze the differences in scan time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the third lumbar vertebral region including the back fat, spinal cord, and cerebrospinal fluid using the mDixon, T2 TSE, and T2 spectral pre-saturation with inversion-recovery (SPIR) techniques. With the factors affecting the SNR fixed, the lumbar sagittal plane images of 30 adults were compared on mDixon, T2 TSE, and T2 SPIR imaging tests. The test times for mDixon, T2 TSE, and T2 SPIR were 115 seconds, 60 seconds, and 60 seconds, respectively. The mDixon T2 images showed higher SNR than the T2 TSE images at the third lumbar vertebral region (p<0.05), lower SNR in the back fat and cerebrospinal fluid (p<0.05) areas, and comparable SNR in the spinal cord (p>0.05). The CNR between the third lumbar vertebral area and back fat was higher in the mDixon T2 images, and the CNR of the cerebrospinal fluid and spinal cord images was higher in the T2 TSE images (p<0.05). The mDixon T2 FS images CNR was lower for the 3rd lumbar vertebral body region and back fat than the T2 SPIR images, and higher for the spinal cord and cerebrospinal fluid images (p<0.05). The CNR between the third lumbar body and back fat areas was higher in the mDixon T2 FS images (p<0.05), and there was no difference in the CNR in the images of the cerebrospinal fluid and the spinal cord (p>0.05). It is difficult to determine whether the mDixon technique is superior to the conventional T2 TSE and T2 SPIR techniques in terms of test time, SNR, and CNR. This study was confined to patients with simple lower back pain and was limited by controlled experimental conditions. Studies using clinically applied protocols are warranted in the future.

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF