Search Result 104, Processing Time 0.018 seconds

Bronchopleural Fistula after Surgery: Therapeutic Efficacy of Bronchial Occluders (수술 후 기관지늑막루: Bronchial Occluder Device의 치료 효과)

  • Young Min Han;Heung Bum Lee;Gong Yong Jin;Kun Yung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.371-381
    • /
    • 2021
  • Purpose To evaluate the usefulness and effectiveness of bronchial occluders in the treatment of postoperative bronchopleural fistula (BPF). Materials and Methods The subjects of the study were six out of seven postoperative BPF patients who underwent surgery due to tuberculosis or lung cancer between 2009 and 2019. Each patient had a bronchial occluder inserted to treat BPF that occurred after surgery. Of the six patients, five had lung cancers and one had tuberculosis. Five were male and one was female; their ages ranged from 59 to 74 years, with an average of 69 years. The diagnosis of BPF was based on findings from bronchoscopy and CT, and treatment was initiated approximately 1 to 2 weeks after diagnosis. The technical and clinical success of the bronchial occluders in the treatment of BPF was evaluated. The study assessed the postoperative clinical effects of the occluders, survival duration, and additional treatments. Results All six patients were successfully treated. Clinical success was achieved in five patients, while partial clinical success was achieved in one; there was no clinical failure. No complications during the migration of the device or device perforations were observed. Two patients were diagnosed with BPF by CT, while four were diagnosed by bronchoscopy. Lobectomy, bilobectomy, and pneumonectomy were performed on two patients each. The periods between surgery and diagnosis ranged from 1 to 34 months; the average was 10 months. Four patients (59-103 days; an average of 80.5 days) died and two (313 days, 3331 days) survived. The causes of death were aggravation of the underlying disease (n = 2), pulmonary edema and pleural effusion (n = 1), and pneumonia (n = 1). Additional catheter drainage was performed in one patient, and a chest tube was maintained in two patients. Conclusion Bronchial occluders are useful and effective in the treatment of BPF after pulmonary resection.

Studies on the Functional Interrelation between the Vestibular Canals and the Extraocular Muscles (미로반규관(迷路半規管)과 외안근(外眼筋)의 기능적(機能的) 관계(關係)에 관(關)한 연구(硏究))

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.1-17
    • /
    • 1974
  • This experiment was designed to explore the specific functional interrelations between the vestibular semicircular canals and the extraocular muscles which may disclose the neural organization, connecting the vestibular canals and each ocular motor nuclei in the brain system, for vestibuloocular reflex mechanism. In urethane anesthetized rabbits, a fine wire insulated except the cut cross section of its tip was inserted into the canals closely to the ampullary receptor organs through the minute holes provided on the osseous canal wall for monopolar stimulation of each canal nerve. All extraocular muscles of both eyes were ligated and cut at their insertio, and the isometric tension and EMG responses of the extraocular muscles to the vestibular canal nerve stimulation were recorded by means of a physiographic recorder. Upon stimulation of the semicircular canal nerve, direction if the eye movement was also observed. The experimental results were as follows. 1) Single canal nerve stimulation with high frequency square waves (240 cps, 0. 1 msec) caused excitation of three extraocular muscles and inhibition of remaining three muscles in the bilateral eyes; stimulation of any canal nerve of a unilateral labyrinth caused excitation (contraction) of the superior rectus, superior oblique and medial rectus muscles and inhibition (relaxation) of the inferior rectus, inferior oblique and lateral rectos muscles in the ipsilateral eye, and it caused the opposite events in the contralateral eye. 2) By the overlapped stimulation of triple canal nerves of a unilateral labyrinth, unidirectional (excitatory or inhibitory) summation of the individual canal effects on a given extraocular muscles was demonstrated, and this indicates that three different canals of a unilateral vestibular system exert similar effect on a given extraocular muscles. 3) Based on the above experimental evidences, a simple rule by which one can define the vestibular excitatory and inhibitory input sources to all the extraocular muscles is proposed; the superior rectus, superior oblique and medial rectus muscles receive excitatory impulses from the ipsilateral vestibular canals, and the inferior rectus, inferior oblique and lateral rectus muscles from the contralateral canals; the opposite relationship applies for vestibular inhibitory impulses to the extraocular muscles. 4) According to the specific direction of the eye movements induced by the individual canal nerve stimulation, an extraocutar muscle exerting major role (a muscle of primary contraction) and two muscles of synergistic contraction could be differentiated in both eyes. 5) When these experimental results were compared to the well known observations of Cohen et al. (1964) made in the cats, extraocular muscles of primary contraction were the same but those of synergistic contraction were partially different. Moreover, the oblique muscle responses to each canal nerve excitation appeared to be all identical. However, the responnes of horizontal (medial and lateral) and vertical (superior and inferior) rectus muscles showed considerable differences. By critical analysis of these data, the author was able to locate theoretical contradictions in the observations of Cohen et al. but not in the author's results. 6) An attempt was also made to compare the functional observation of this experiment to the morphological findings of Carpenter and his associates obtained by degeneration experiments in the monkeys, and it was able to find some significant coincidence between there two works of different approach. In summary, the author has demonstrated that the well known observations of Cohen et al. on the vestibulo-ocular interrelation contain important experimental errors which can he proved by theoretical evaluation and substantiated by a series of experiments. Based on such experimental evidences, a new rule is proposed to define the interrelation between the vestibular canals and the extraocular muscles.

  • PDF

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.