• 제목/요약/키워드: 산소포화

Search Result 420, Processing Time 0.025 seconds

The Resting and Exercise Related Oxygen Desaturation as the Associated Factor for Sleep Related Oxygen Desaturation in Patients with Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환 환자의 수면 중 산소포화도 감소에 대한 예측인자로서 안정시 및 운동시 산소포화도)

  • Shin, Chang-Jin;Lee, Kwan-Ho;Park, Hye-Jung;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.231-238
    • /
    • 1999
  • Background: Nocturnal hypoxemia occurs in patients with chronic obstructive pulmonary disease(COPD) and the detection and treatment of nocturnal hypoxemia should be part of the management of COPD patients. We performed this study to evaluate the factors influencing to sleep related arterial oxygen desaturation($SaO_2$) in patients with COPD. Methods: Resting and exercise cardiopulmonary function test, polysomnography, and $SaO_2$ during resting, exercise and sleep were measured in 12 patients with COPD. Results: The $SaO_2$ fell twice as much during sleep as during maximal exercise($13.1{\pm}9.3%$ fall in nocturnal $SaO_2$ vs. $6.4{\pm}3.3%$, p<0.05). Fall in nocturnal $SaO_2$ was well correlated with mean exercise $SaO_2$(r=-0.78, p<0.05), minimum exercise $SaO_2$(r=-0.90, p<0.01), and resting $SaO_2$(Cr=-0.82, p<0.05). Lowest sleep $SaO_2$ was well correlated with mean exercise $SaO_2$(r=0.80, p<0.05), lowest exercise $SaO_2$(r=0.90, p<0.01), and resting $SaO_2$(r=0.84, p<0.05). Conclusion: Resting and exercise $SaO_2$ was well correlated with nocturnal $SaO_2$, but exercise study add no additional information to predicting the nocturnal oxygen desaturation in patients with COPD.

  • PDF

A study on Oxygen saturation measurement using non-switching method (non-switching 방식을 이용한 산소포화도 측정에 관한 연구)

  • Lee, Chung-Luyl;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.01a
    • /
    • pp.115-117
    • /
    • 2013
  • 본 논문에서는 660nm 파장의 적색광과 940nm 파장의 적외선을 활용한 광전용적맥파(photoplethysmo graphy:PPG)를 기반으로 한 산소포화도 측정에 대하여 연구하였다. 본 논문에서는 기존의 한 손가락에서 서로 다른 두 파장의 광(光)을 번갈아 켜고 끄며 측정하던 산소포화도 측정방식과 달리 서로 다른 두 파장의 광을 각각 서로 다른 손가락에서 측정 한 후 각각의 광전용적맥파를 통하여 산소포화도를 측정할 수 있는 방법을 제안하였다. 이 방법은 동시에 한곳에서 측정할 때와 달리 서로 다른 두광을 Switching할 필요 없이 동시에 측정 가능하며 이를 통하여 서로 다른 곳에서 측정한 광전용적맥파를 이용하여 산소포화도 측정이 가능하다는 결론을 얻었다.

  • PDF

Implementation of the Wearable SpO2 Monitoring System Using Optical Compensation Method (광보정기법을 적용한 착용형 산소포화도 모니터링 시스템 구현)

  • Kim, Hyun-Su;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.879-881
    • /
    • 2016
  • 비침습적 맥파측정은 일상생활에서 손쉽게 활용이 가능하며 맥파신호의 계측을 통하여 건강모니터링을 함으로서 사용자의 지속적인 건강관리에 도움이 된다. 일반적인 맥파 측정을 위해선 경동맥, 대퇴골, 요골 동맥을 포함 만져서 할 수 있는 동맥에서 측정되거나 맥파 측정장비를 사용하여 측정하게 된다. 본 연구에서는 실시간 맥파측정과 병행하여 산소포화도의 모니터링을 위해 손목착용형 시스템을 구현하고 산소포화도의 추정 정확도를 높이기 위하여 광보정기법을 적용하였다. 실제 자연광 상태에서의 측정된 신호를 이용하여 광보정기법을 적용한 산소포화도 모니터링 기법을 적용하고 그 성능평가를 수행하였다.

  • PDF

A Study on the Development of Pulse Oximeter based on Standard Protocol (표준 프로토콜 기반의 산소포화도 계측기(SPo2) 개발에 관한 연구)

  • Kang, Sung-In;Park, Yoon-A;Oh, Am-Suk;Jean, Je-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.751-753
    • /
    • 2011
  • Pulse Oximeter is used two different wavelength light sources. Two signals measured by light transmission in the body parts. SPo2 is calculated from the measured signal. These optical methods is have the light absorption properties of oxygen in the blood. SPo2 is to be called vital signs of $5^{th}$and important in modern medical. But, exist pulse oximeter was used just user for viewing the SPo2. That was a lack of used communication Monitoring function. In this paper using the Bluetooth feature on the exist pulse oximeter to communicate with the outside of the Gateway for design medical devices standards protocol IEEE 11073-10404 built-in pulse oximeter. Also user can be monitoring the U-Health Gateway through the pass SPo2 information.

  • PDF

Development of Optical Sensor for Non-invasive Oxygen Saturation Measurement (비추출식 산소 포화도 측정용 광센서의 연구 개발)

  • Kwon, Ki-Jin;Park, Se-Kwang;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.133-141
    • /
    • 1991
  • 혈중 산소 포화도는 생체의 중요한 정보로써 많은 학자들이 산소 포화도를 비추출방법으로 측정하기 위한 이론과 센서의 제작에 관해서 연구를 하고 있다. 혈액에서의 빗의 흡수(Absorption)와 산란(Scattering)에 관한 이론 연구가 Ishimaru, Takatani. Johnson 등의 학자들에 의해 진행되었고, Polanyi, Hehir, Johnson, Schmitt등에 의해서 센서 구조와 센서 제작에 관한 연구가 진행되고 있다. 산소 포화도를 직접 혈액을 추출하지 않고 비추출식으로 측정하게 된다면, 최근 우리나라에서도 인공 심장이 개발되고 있으므로 인공 심장의 제어에 필요한 정보로써 산소 포화도를 신속 정확하게 공급할 수 있어 인공 심장의 정확한 재어가 가능하다. 그리고 반도체 기술을 이용하여 소형화가 가능하므로 생체 적용성(Biocompatibility)이 우수하고 다기능을 가진 센서를 만들 수 있다. 본 논문에서는 비추출식으로 산소 포화도를 측정하기 위한 투과광 방식과 반사광 방식의 기본 이론 및 센서의 설계를 위한 기본 이론을 분석하였다. 그리고, 적색광의 사용가능성을 테스트하기 위한 모의 실험도 행하였다.

  • PDF

Nocturnal Arterial Oxygen Saturation Monitoring in Patients with Respiratory Disease (호흡기 질환 환자들에서 야간 동맥혈 산소포화도 감시 성적)

  • Choi, In-Seon;Yang, Jae-Beom;Kim, Young-Chul;Chung, Ik-Joo;Kang, Yu-Ho;Koh, Yeoung-Il;Park, Sang-Seon;Lee, Min-Su;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.103-110
    • /
    • 1994
  • To find out the predictors of nocturnal arterial oxygen desaturation in patients with respiratory diseases, transcutaneous oxygen saturation($StcO_2$) monitoring studies using a pulse oximeter were performed during sleep in 20 patients. $StcO_2$ was decreased more than 4% from the baseline value in 18 patients(90%) and more than 10%("Desaturator") in 8(40%). Five of the seven patients(71.4%) with awake $PaO_2$<60mmHg and three of the thirteen patients(23.1%) with awake $PaO_2{\geq}60mmHg$ were "desaturators". The awake $PaO_2/FIO_2$ and $PaO_2/PAO_2$ could distinguish "desaturator" from "nondesaturator", and $PaO_2,\;SaO_2$ or $StcO_2$ could not. These results suggest that the nocturnal oxygen desaturation depends on the severity of the underlying disease rather than the baseline $PaO_2$. Anthropomorphic and lung function factors could not separate between "desaturator" and "non-desaturator", and about a quater of patients with a wake $PaO_2{\geq}60mmHg$ developed significant desaturation. Therefore, it is necessary to monitor the nocturnal arterial oxygen saturation in patients with respiratory diseases regardless of their severity of airflow obstruction or awake $PaO_2$.

  • PDF

Changes of $SPO_2$, heart rate and GSR at resting state due to oxygen administration (안정상태에서 외부의 산소공급에 따른 혈중산소포화도, 심박동율, 피부전도도의 변화)

  • 정순철;이현정;민병찬;김승철
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.71-73
    • /
    • 2003
  • 본 연구에서는 안정 상태에서 일반 공기 중에 산소 농도(21%) 환경에 비해 외부에서 고 농도(35%)의 산소 공급이 혈중 산소 포화도(SPO2), 심박동율(Heart rate), 피부전도도(Galvanic skin response)에 어떠한 영향을 미치는지를 검증하고자 한다. 35%의 고농도 산소를 2L/min의 양으로 일정하게 공급할 수 있는 산소 공급 장치를 이용하였고, 뇌 질병이 없는 5명의 대학생들이 피험자로 참여하였다. 21%의 비해 35% 산소 농도에서 모든 실험 참여자의 3분 동안의 평균 심박동율은 감소하였고 평균 혈중 산소 포화도는 증가하였다. 그러나 피부전도도는 차이가 없었다.

  • PDF

A Study on the Algorithm on Computing Model of Pulse Oximetry Using 2 Channel Sensor (2 채널 센서 펄스 옥시메터의 산소포화도 계산알고리즘에 관한 연구)

  • 김동철;이윤선;이경중;이성호
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.573-579
    • /
    • 1999
  • 본 논문은 2채널 센서를 이용한 펄스 옥시메터의 산소포화도 계산 모델의 설계 및 분석에 관한 것이었다. 또한 Beer Lambert 법칙에 의거하여 기존 알고리즘 및 새로운 알고리즘들을 이론적으로 분석하였다. 제안된 알고리즘은 손가락을 투과한 2개의 채널에서 나온 광신호를 각각 직류성분 Adc 와 맥동성문 Aasin wt. 잡음성분 Ahnoise , ALnoise 등으로 모델링한다. 모델링 되어진 광신호를 맥동성분이 적분비를 사용하여 고주파 동잡음인 AHnoise 를 제거한 후 각각 산소포화도 계산을 위한 상관계수 그래프를 구한다. 또한 2개의 채널에서 적분비를 사용하여 구해진 상관계수 그래프를 사용하여 산소농도를 추출하는 방법에 관하여 기술하였다. 맥동성분비와 관혈적인 측정에 의한 혈중 산소포화도와의 상관관계 그래프의 선형성을 확보하기 위하여 펄스 옥시메터 시뮬레이터 오차범위를 고려해 75~100%상이의 산소포화도를 중점적으로 관측하였고, 4주기로 면적계산주기를 결정하여 실험하였다. 본 연구에서 제안된 알고리즘의 성능평가는 맥동성분의 적분비를 이용한 방법과 비교하였다. 비교결과는 4주기의 면적계산 주기를 가졌을 때 기존의 방식보다 평균오차가 0.7%정도 향상되었으며, 회귀적선의 신뢰도를 보여주는 결정계수 ${\gamma}$$^2$도 0.995로 기존의 방식에서 나온 0.979보다 더 좋은 결과를 얻을 수 있었다. 따라서 2채널을 이용한 방법이 A Lnoise 제거와 성능면에서 우수하다는 결론을 얻을 수 있었다.

  • PDF

Feeding Desaturation and Effects of Orocutaneous Stimulation in Extremely Low Birth Weight Infants (초극소 저체중 출생아에서 수유 시 산소포화도 저하와 구강자극 요법의 효과)

  • Choi, Hae-Won;Park, Hye-Won;Kim, Hee-Young;Lim, Gi-Na;Koo, So-Eun;Lee, Byong-Sop;Kim, Ai-Rhan;Kim, Ki-Soo;Pi, Soo-Young
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.193-200
    • /
    • 2010
  • Purpose: Feeding desaturation is a common problem among preterm infants which can result in prolonged hospital stays, longterm feeding difficulties and growth delay. The purpose of this study was to identify the characteristics of premature infants with feeding desaturation and to examine the effect of orocutaneous stimulation on oral feeding. Methods: During the first phase of this study, 125 extremely low birth weight infants were reviewed retrospectively. Characteristics between infants with feeding desaturation (n=34) and those without feeding desaturation (n=91) were examined. During the second phase, 29 infants recruited from March, 2009 to May, 2010 were subjected to orocutaneous stimulation. The results of orocutaneous stimulation were compared to a control group (n=81). Results: The first phase of the study revealed that extremely low birth weight infants with feeding desaturation were significantly lower in gestational ages at birth, and had lower 5 minute apgar scores, more gastroesophageal refluxes and bronchopulmonary dysplasia. Infants without feeding desaturation reached full enteral feeding significantly earlier and showed shorter duration of hospital stay. At the second phase, infants in the intervention group showed shorter days to achieve initiation of bottle feeding, shorter days in achievement of full bottle feeding, last episodes of feeding desaturation and length of hospital stay compared to the control group of similar characteristics. Conclusion: Orocutaneous stimulation among extremely low birth weight infants results in earlier achievement of full bottle feedings without episodes of feeding desaturation hence shortens the length of hospital stay.

Design of an $SpO_2$ Transmission Agent based on ISO/IEEE 11073 Standard Protocol (ISO/IEEE 11073 표준 프로토콜 기반의 산소포화도 전송 에이전트 설계)

  • Pak, Ju-Geon;Im, Sung-Hyun;Park, Kee-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.462-465
    • /
    • 2011
  • A pulse oximeter is a device which provides non-invasive estimate of percentage oxygen saturation of haemoglobin (SpO2). Due to the limitations of resources of personal health devices (PHDs) including pulse oximeters, they generally transmit the estimated data to a remote monitoring server through a close manager (e.g. mobile device or PC). Therefore, communication protocols between PHDs and a manager is an important research topic in terms of interoperability. In this paper, we present design results of an SpO2 transmission agent based on the ISO/IEEE 11073 (X73) protocol. The protocol is an international standard for PHDs. The agent is an embedded program which generates X73 messages from the estimated pulse rates and SpO2, and transmits the messages to a close manager. The agent consists of a Session, Message and Memory Handler. The Session Handler manages a communication session with the manager, and the Message Handler generates and analyzes the exchanged messages according to the X73 protocol. The Memory Handler extracts pulse rates and SpO2s which are stored in a memory of the pulse oximeter. The SpO2 transmission agent allows pulse oximeters to communicate with managers based on x73 standard. Consequently, the interoperability between the pulse oximeters and the managers is guaranteed.

  • PDF