• Title/Summary/Keyword: 산란간격

Search Result 135, Processing Time 0.026 seconds

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

Corn-Based Forage Cropping Systems in Rice Black-Streaked Dwarf Virus Prevalent Area (흑조위축병이 심한 남부지방에서 옥수수를 중심으로 한 사료작물 작부체계)

  • 이석순;이진모
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.1
    • /
    • pp.30-39
    • /
    • 1989
  • Forage productivity of cropping systems of rye - silage corn, silage corn - oats, silage corn - rape was studied in the south-eastern part of Korea where rice black-streaked dwarf virus(RBSDV) infection of corn are severe. Rye(cv. Paldanghomil) was planted on Oct. 20 of 1986 and harvested 10 times from April 5 to May 5 at the 5-day intervals in 1987, corn (cv. Suweon 19 and Jinjuok) was planted 5 times from April 5 to May 15 at the 10-day intervals in 1987, and oats(cv. Megwiri) and rape (cv. Velox) were planted 4 times from Sept: 4 to 25 at the 7-day intervals and harvested 4 times from Nov. 10 to Dec. 10 at the 10-day intervals in 1987. Considering yield, nutrition value, and in vitro dry matter digestibility (IVDMD), forage productivity of the cropping systems was compared. As harvesting time of rye delayed, plant height, dry matter(DM) yield, percent DM, crude fiber, and digestible DM yield increased, but crude protein, crude fat, and IVDMD decreased. However, nitrogen free extract was not different among the harvesting dates. As planting date of corn delayed, RBSDV infection rate increased. but DM yield of silage decreased. However, silage yield of Jinjuok was higher, but RBSDV infection rate was lower compared with Suweon 19 at all planting dates. DM yield of oats and rape decreased as planting date delayed. However, at Sept. 4 and 11 plantings yield of oats on Nov. 10 was much lower than that of rape, but the differences in yield between two crops decreased with delayed harvesting, and yield was similar on Dec. 10. A cropping system harvesting rye around April 20 and followed by planting corn in late April was best among the rye-corn systems considering yield and nutrition value of both crops. However, among the corn-oats or corn-rape cropping systems early April planting of corn and followed by early Sept. planting of oats or rape showed best results with similar yield potential of the best rye-corn cropping system.

  • PDF

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Seasonal Development and Control of Parthenolecanium corni in Blueberry Shrubs (블루베리에 발생하는 말채나무공깍지벌레의 계절적 발육과 방제)

  • Lee, Seok-Min;Chung, Bu-Keun;Kang, Dong-Wan;Park, Kyung-Mi;Han, In-Young;Kwon, Jin-Hyeuk;Lee, Heung-Su
    • Korean journal of applied entomology
    • /
    • v.60 no.4
    • /
    • pp.403-415
    • /
    • 2021
  • Seasonal development of Parthenolecanium corni was observed from 4 Jun. 2019 (nymph) - 25 Jun. 2020 (1st Gen. nymph) in blueberry shrub in Sacheon city, Gyeongsangnam-do. To investigate their development, more than 5 twigs sprouted in 2018 were taken from the farm nearly weekly basis. The development of each scale were examined under the stereomicroscope and chemical control was conducted in the blueberry shrub with available three insecticides. The results on the development period and Centigrade Degree-Days accumulation (DDC) obtained are as follows: egg-laying period (peak): 12 -26 May 2020 (24 May)(DDC, 110.0-188.5 (173.6)); egg-hatching period (peak): 9 - 23 June 2020 (19 June)(DDC, 325.2-480.8(435.6); egg period: 26 days; nymph movement from overwintered adult to new leaves 16-25 June 2020 (DDC, 410,5-500.4); nymph movement from leaf to twig (peak) to become adult: 4-18 Feb. 2020 (8 Feb.). Eggs no. /adult (range): 956.8 ± 73.4 (13 - 3497). Size (mm) of egg, 0.29 ± 0.020(L), 0.15 ± 0.013(W); of egg-hatched nymph, 0.35 ± 0.018(L), 0.18 ± 0.007(W), 0.09 ± 0.007(eye distance); and of adult, 4.30 ± 0.893(L), 2.64 ± 0.520(W). The egg-hatched nymphs from the overwintered adult moved to the backside leaf of new shoot in which they found about 95% until leaf is falling by early February in next year. They overwintered as 2nd instar and occurred univoltine. For the control of the 1st instar crawler, three insecticides treated on 16 and 30 July at the registered dose for Ceroplastes japonicus. Acetamiprid 8WP showed 96.9% mortality at 21 days after 1st treatment.

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

Comparison of Particulate Matter and Ammonia Emission in Different Types of Laying Hen Poultry Houses during Spring (봄철 산란계사 사육형태별 미세먼지 및 암모니아 농도 비교)

  • Hong, Eui-Chul;Kang, Bo-Seok;Kang, Hwan-Ku;Jeon, Jin-Joo;You, Are-Sun;Kim, Hyun-Soo;Son, Jiseon;Kim, Hee-Jin;Yun, Yeon-Seo
    • Korean Journal of Poultry Science
    • /
    • v.48 no.3
    • /
    • pp.151-160
    • /
    • 2021
  • This study was conducted to determine the concentrations of particulate matter (PM) and NH3 emissions from different types of laying hens poultry houses during spring. The concentrations of PM and NH3 were measured three times (2-week intervals; March to May) in Floor-pen-, Aviary-, and Cage-type poultry houses. Overall, PM10 and PM2.5 concentrations were found to be low from 22:00 to 04:00. The PM10 and PM2.5 concentrations in Floor-pen and Cage houses were similar with no significant daily deviation. NH3 concentrations measured over 24 h at the center and end of Floor-pen house were relatively constant. Irrespective of measurement location, NH3 concentrations were the lowest in Floor-pen house. Moreover, NH3 concentrations were higher at the end of Floor-pen and Aviary houses than that at the center; however, lower concentrations of NH3 were detected at the end of Cage house. The concentrations of PM10 and PM2.5 around the poultry houses were 57.5 and 34.0 ㎍/m3, respectively, with the daily average PM10 and PM2.5 concentrations (4,730 and 447.7 ㎍/m3, respective) being the highest in Aviary house. The concentrations of NH3 at the center and end of Cage house were the highest at 12.0 and 9.31 ppm, respectively. Furthermore, in Cage house, the emission factor of NH3 was the lowest, whereas there was no significant difference on that of NH3. In conclusion, among the three types of poultry houses assessed, PM (PM10, PM2.5) concentrations were higher in Aviary house, whereas NH3 concentrations were higher in Cage house.

Concentration of Particulate Matter and Ammonia Emitted by Breeding Type of Laying Hen Houses in Winter (동절기 산란계사 사육형태별 배출되는 미세먼지 및 암모니아 농도)

  • Hong, Eui-Chul;Kang, Bo-Seok;Kang, Hwan-Ku;Jeon, Jin-Joo;You, Are-Sun;Kim, Hyun-Soo;Son, Jiseon;Kim, Hee-Jin;Kim, Kwang-Yeol;Yun, Yeon-Seo
    • Korean Journal of Poultry Science
    • /
    • v.48 no.1
    • /
    • pp.23-30
    • /
    • 2021
  • In this study, we measured the concentration of particulate matter (PM) and ammonia (NH3) emission in the winters according to the breeding type of laying hen houses. Measurements were performed thrice in Barn, Aviary, and Cage houses every 2 weeks from December to January. The changes in the PM10 and PM2.5 concentrations were similar in all three breeding types. The PM10 and PM2.5 concentrations, measured three times, were the highest in the Aviary house. In the results measured by time, the PM10 and PM2.5 concentrations were the lowest during the dark period (22:00 to 4:00) of the day. The NH3 concentration was the highest in the Cage house and the lowest in the Barn house. Regarding emissions over time, the results of the three measurements showed different patterns and differed from those of the PM. In addition, with passage of time from the 1st (december) to 3rd (january), the NH3 concentration gradually increased. The daily PM10 and PM2.5 concentrations in the Aviary house, which were higher than those of the other houses, were 4,787 ㎍/㎥ and 388.6 ㎍/㎥, respectively, while, the PM10 and PM2.5 concentrations outside the poultry houses were 226.0 ㎍/㎥ and 39.3 ㎍/㎥, respectively. The daily NH3 concentration was 7.70 ppm and 9.20 ppm at the center and end of the Cage house, respectively. This was higher than that in the other houses. In conclusion, the concentrations of PM (PM10, PM2.5) and NH3 were the highest in the Aviary and Cage laying hen houses, respectively.

Production of Lignan-Rich Eggs as Functional Food by Supplementing Schisandra chinensis By-Product in Laying Hens (사료에 오미자 가공부산물 분말의 첨가 급여가 계란의 리그난 함량에 미치는 영향)

  • Hye Mi Kang;Eun Ji Park;Sun Young Park;Dae Youn Hwang;Jong-Choon Lee;Myunghoo Kim;Young Whan Choi
    • Journal of Life Science
    • /
    • v.34 no.1
    • /
    • pp.18-27
    • /
    • 2024
  • Laying hens are known to be able to 'bio-accumulate' the health-promoting ingredients of their diet into eggs. The purpose of this study was to characterize lignan-rich eggs as functional food fed with Schisandra fruit by-product (SCP). Experimental diets were formulated using yellow corn, rice bran, soybean meal, fish meal, meat bone meal, poultry meal, vitamin premix, mineral premix, CaCO3, and supplemented Schisandra chinensis by-product. This experiment conducted a completely randomized design with 5 treatments for 5 laying hens. Levels of SCP were fed control diet or each formulated diet containing 1%, 3%, 5% and 7% SCP powder. The weight of eggs and the lignan content in white and yolk of egg were investigated every 7 days. Egg production and egg weight were not affected by diet at less than 5% SCP in the diet, but were significantly reduced when the diet was supplemented with a high concentration of 7% SCP after 3 weeks. Yolks and white in eggs were analyzed by using a high performance liquid chromatography (HPLC) to determine the lignans profile. Higher dietary SCP supplementation significantly increased gomisin N and schisandrin C in Acetonitrile (p<0.05). Gomisin N in egg white increased in a concentration-dependent manner, but shisandrin C not detected. These results indicated that the use of SCP powder in layering diets was effective in egg quality and for the production of lignans fortified eggs. In conclusion, dietary supplementation of Schisandra by-product with less than 5% can produce lignans-enrich eggs used as functional foods.