• Title/Summary/Keyword: 사출수

Search Result 373, Processing Time 0.034 seconds

Development of Pellet-type Artificial Diet for Lepidopteran Insect by Using a Twin Screw Extruder (나비목 곤충용 펠렛사료 조제법 개발)

  • Seol Kwang-Youl;Hong Seong-Jin;Kim Nam-Jung;Kim Seong-Hyun
    • Korean journal of applied entomology
    • /
    • v.45 no.1 s.142
    • /
    • pp.75-78
    • /
    • 2006
  • Development of pellet-type artificial diet for insect was tried by using a twin screw extruder(TSE). Screws were arranged several times and two reverse screws were equipped on the foreparts of 2 axes of TSE. Pellet-type diet could be produced successfully under conditions of TSE set as the following. : 300 rpm of main motor speed, 228 rpm of feed motor speed, $75m{\ell}/min$ of running water speed and 5 mm of extrusion diameter. The optimum adding quantity of water to the manufactured diet was $1.2{\sim}1.5$ times of dry diet. On the rearing results of beet armyworm, Spodoptera exigua and common cutworm, Spedoptera litura with the pellet-type diet, the final survival ratio (emergence rate) of these two species was over than 50%, and so it was concluded that the manufactured pellet-type artificial diet was sufficient dietetically to rear those insects.

A Study on the Characteristics of IR/CR Rubber Blends by Surface Treatment with Chlorine (염소의 표면처리에 따른 IR 및 CR Blend의 특성 연구)

  • Park, Ji-Hye;Lee, Chang-Seop;Park, Hyun-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.6
    • /
    • pp.749-754
    • /
    • 2010
  • In this study, rubber vulcanization property, change in physical property, morphology and chemical characteristics of blended rubber depending on various IR/CR ratio were investigated for the purpose of the improvement of material property and durability. The effect of surface treatment by chlorine on the friction coefficient was also studied with various conditions of surface treatment. In terms of vulcanization property, as the amount of CR content increased, the speed of cure was decreased, while the density of crosslinking stayed constant. It means hardness and modulus were increased as the CR content increased. It is related to change in cure property and mechanical strength was improved by the effect of crystallization reaction. In the aging property, as the CR content increases, the changed amount of basic properties were decreased, which acts as a reducing factor in change of aged property by complementing weak point in mechanical property. It was found that the degree of property change for surface treated samples were reduced. According to the microscopic result, the degree of surface dispersion on rubber blends was increased by increasing CR content. Rubber surface showed uniform direction in pattern with increased smoothness and luster by treatment with chlorine. The degree of rubber reforming was measured by the remaining amount of chlorine and the friction coefficient was dependent on the amount of chlorine combined with rubber. In the initial stage of surface treatment, from 10 to 40 phr, the friction coefficient of specimen was rapidly reduced. However, as the concentration of chlorine solution increased, the change in friction coefficient was decreased.

A Study on the Stress Measurement in a Plastic Product using Chemical Cracking Method (케미칼 크랙킹 방법을 이용한 플라스틱 제품의 응력측정에 관한 연구)

  • Won, S.T.;Kim, T.B.;Lee, S.;Won, J.M.;Cha, K.H.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.47 no.4
    • /
    • pp.336-340
    • /
    • 2012
  • Residual stress in the injection molded part is originated from thermal shrinkage and shear stress during injection molding process. There are many measurement methods of residual stress in the plastic part. Residual stress in opaque products can be measured by chemical cracking test. This method enables the solvent and specimen to react and to cause cracks. Cracks developed according to the level of residual stress. Thus the stresses in plastic part can be quantitatively measured by counting the number of cracks or measuring the size of cracks. Relationship between stress and number of cracks in a plastic specimen has been investigated in this study. Bergen jig was used to give a strain in the specimens those were molded using PC/PBT and PC/ABS. Solvent for the chemical cracking test was prepared using tetrahydrofuran and methyl alcol with the ratio of 1 to 3. Stresses in the specimen can be calculated by strains those were imposed by Bergen jig. Cracks were developed for stress higher than certain level. The number of cracks increased by second order function for stress.

Viability and Acrosomal Status Changes Following Post-thawing Canine Spermatozoa (개 정자의 동결융해 후 생존성 및 첨체의 변화)

  • 이영락;이성림;강태영;최상용
    • Journal of Embryo Transfer
    • /
    • v.18 no.1
    • /
    • pp.51-59
    • /
    • 2003
  • This study was carried out to evaluate the effect of different freezing and thawing rates on the viability, motility and acrosomal changes of frozen canine spermatozoa. The ejaculated semen was extended with Tris-egg yolk buffer containing 8% glycerol and equilibrated for 60 min after cooled to 4$^{\circ}C$ for 58 min. The straws were cryopreserved gradually by slow-cooling at different distance(6, 10 and 17 cm, respectively) from the liquid nitrogen (L$N_2$) to achieve temperature rate of 3, 8.9 and 19$^{\circ}C$ /min. Thawing of the straws was performed in a water bath fur 2 min at 37$^{\circ}C$ and 55$^{\circ}C$ , respectively. The motility of frozen-thawed spermatozoa was assessed by phase-contrast microscopy. To assess their viability and acrosome content, spermatozoa were stained with a vital stain and Fluorescence conjugated lectin Pisum Savitum Agglutinin (FITC/PAS), respectively. Concentration of the ejaculated fresh semen was normal range of 3.44 $\times$ 10$^{8}$ /ml. Freezing temperature were reduced to -110, -70 and -35$^{\circ}C$, as higher distance from liquid nitrogen, 6, 10 and 17 cm, respectively. Freezing at 3$^{\circ}C$/min in distance of 17 cm from liquid nitrogen yielded better motility, viability and rate of intact acrosome than 8.9 or 19$^{\circ}C$/min and the optimal thawing was 37$^{\circ}C$ for 2 min.

An Improved Manufacturing Method of p-Dicyclopentadiene (DCPD) using Tungsten Type Catalyst in Air Condition (대기 조건에서 경화가 가능한 텅스텐계 p-DCPD의 개선된 성형 방법)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Joung-Man
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Ring-opening metathesis polymerization of p-dicyclopentadiene (DCPD) can be performed using the tungsten type catalyst. This reaction usually progresses in nitrogen condition, because the catalysts are extremely sensitive in air condition. To solve this problem, DCPD resin with tungsten (W) was cured using hot press after stirring of DCPD A and B liquid in air condition. Mechanical properties of DCPD were improved by reducing microvoid occurrence successfully by using hot press method. It might be because hot press could provide sufficient press on DCPD specimen. Addition of catalyst was not effective for the curing of resin in a short time. During polymerization, pressure and temperature had a great influence on the mechanical properties of DCPD.

Rheological characterization of thermoplasticized injectable gutta percha and resilon (열연화주입형 gutta percha와 resilon의 유변학적 특성)

  • Chang, Ju-Hea;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.377-384
    • /
    • 2011
  • Objectives: The purpose of this study was to observe the change in the viscoelastic properties of thermoplasticized injectable root canal filling materials as a function of temperature and to compare the handling characteristics of these materials. Materials and Methods: Three commercial gutta perchas and Resilon (Pentron Clinical Technologies) in a pellet form were heated in the Obtura-II system (Obtura Spartan) at $140^{\circ}C$ and $200^{\circ}C$, and the extrusion temperature of the thermoplasticized materials was measured. The viscoelastic properties of the materials as a function of temperature were evaluated using a rheometer. The elastic modulus G', viscous modulus G", loss tangent tan${\delta}$, and complex viscosity ${\eta}^*$ were determined. The phase transition temperature was determined by both the rheometer and a differential scanning calorimeter (DSC). The consistency of the materials was compared under compacting pressure at $60^{\circ}C$ and $40^{\circ}C$ by a squeeze test. Results: The three gutta perchas had dissimilar profiles in viscoelastic properties with varying temperature. The phase transition of softened materials into solidification occurred at $40^{\circ}C$ to $50^{\circ}C$, and the onset temperatures obtained by a rheometer and a DSC were similar to each other. The onset temperature of phase transition and the consistency upon compaction pressure were different among the materials (p < 0.05). Resilon had a rheologically similar pattern to the gutta perchas, and was featured between high and low-flow gutta perchas. Conclusions: The rheological characteristics of the thermoplasticized root canal filling materials changed under a cooling process. The dissimilar viscoelastic properties among the materials require different handling characteristics during an injecting and compacting procedure.

Fabrication and Property of Ba0.5Sr0.5Co0.8Fe0.2O3-δ Hollow Fiber Membranes (Ba0.5Sr0.5Co0.8Fe0.2O3-δ 중공사 분리막의 제조 및 물성)

  • Jeon, Sung Il;Park, Jung Hoon;Kim, Jong Pyo;Sim, Woo Jong;Lee, Yong Taek
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ hollow fiber with o.d. 1.02 mm and i.d. 0.437 mm were fabricated by a phase-inversion spinning technique.The starting $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ precursor was synthesized by the polymerized complex method and then calcined at $900^{\circ}C$. As-prepared powder was dispersed in a polymer solution, and extruded as form of hollow fiber through a spinneret. Finallydense $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ hollow fiber membrane was obtained by sintering for 2 h at $1,080^{\circ}C$ for the application of oxygen separation. In addition, despite a very thin membrane with 0.58 mm, the BSCF hollow fiber membrane possessed a proper mechanical strength of 602.5 MPa.

A Study on the Warpage of Glass Fiber Reinforced Plastics for Part Design and Operation Condition: Part 1. Amorphous Plastics (유리섬유로 보강된 수지에서 제품설계 및 성형조건에 따른 휨의 연구: Part 1. 비결정성 수지)

  • Lee, Min;Kim, Hyeok;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.36 no.5
    • /
    • pp.555-563
    • /
    • 2012
  • Warpage of injection molded product is caused by non-uniform shrinkage during shaping operation and relaxation of residual stress. Robust part design and glass fiber reinforced reins have been adopted to prevent warpage of part. Warpages for part designs have been investigated in this study according to the injection molding conditions. Part design contains flat specimen and two different rib designs in the flat part. Resins used in this study were glass fiber reinforced amorphous plastics, PC and ABS. Different rib designs showed significant differences of warpages in the parts. Various warpages have been observed in the three regions of the part, near gate region, opposite region to the gate, and flow direction region. Results of computer simulation revealed that the warpages were strongly related to glass fiber orientation. Flat specimen showed the smallest warpage and the specimen with ribs to the flow direction showed a high resistance to warpage. Warpage highly depended upon part design rather than molding condition. It was concluded that the rib design and selection of gate location in injection molding would be the most important factors for the control of warpage since those are directly related to the fiber orientation during molding.

Effects of Gluten and Moisture Contents on Texturization of Extruded Soy Protein Isolate (글루텐 함량과 수분 함량이 압출성형 분리대두단백의 조직화에 미치는 영향)

  • Park, Ji-Hoon;Chatpaisarn, Apapan;Ryu, Gi-Hyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 2017
  • The aim of this study was to investigate the effects of gluten and moisture contents on the physical properties of extruded soy protein isolate. Extrusion conditions included various moisture (45, 50, and 55%) and gluten contents (20, 40, and 60%) at a fixed screw speed and die temperature of 250 rpm and $140^{\circ}C$, respectively. Specific mechanical energy input decreased as gluten content increased from 20 to 60%. Hydration ratio was highest ($293.23{\pm}13.68%$) at gluten and moisture contents of 20 and 55%, respectively. Lightness and yellowness increased as gluten content increased from 20 to 60% while redness decreased as gluten content increased. Color difference was the highest at low gluten and moisture contents. Integrity index was the highest ($71.15{\pm}0.93%$) at gluten and moisture contents of 60 and 45%, respectively. Nitrogen solubility index was not significantly affected by moisture content and was lowest ($22.46{\pm}1.11%$) at gluten and moisture contents of 60 and 55%, respectively. In conclusion, higher gluten and lower moisture contents were effective for texturization of soy protein isolate.

Stress Distribution in Microvascular Anastomotic Coupler (AnaFix®) Micropins with Respect to the Fillet Radius (필렛효과에 따른 미세혈관 문합커플러(AnaFix®) 마이크로핀의 응력분포)

  • Jee, Dae-Won;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1139-1145
    • /
    • 2011
  • An automated anastomotic ring-pin system consisting of both the anastomotic ring-pin system and the coupler device has eliminated the drawbacks of the suture method. High density polyethylene (HDPE), a material with outstanding biocompatibility and injection molding capability, was used in the ring. SUS316 stainless steel, Ti-6Al-4Nb, Ti-6Al-4V, and unalloyed titanium were used in FEM simulations of the micropin. The authors categorized the microvascular anastomotic ring micropins into short neck (SN) and long neck (LN) groups in order to evaluate the effect of the micropin's fillet radius and neck length on the von Mises stress. The micropins were further divided into those with and without fillet. On the basis of the fillet radius rate (FRR), which represents the rate of change in the von Mises stress with respect to the availability and shape of the fillet, and the neck length rate (NLR), which represents the rate of change in the von Mises stress with respect to changes in the length of the neck within the fillet shape, it can be concluded that the SN-3 neck design is the most stable.