• Title/Summary/Keyword: 사체

Search Result 729, Processing Time 0.023 seconds

A Deep Learning-based Real-time Deblurring Algorithm on HD Resolution (HD 해상도에서 실시간 구동이 가능한 딥러닝 기반 블러 제거 알고리즘)

  • Shim, Kyujin;Ko, Kangwook;Yoon, Sungjoon;Ha, Namkoo;Lee, Minseok;Jang, Hyunsung;Kwon, Kuyong;Kim, Eunjoon;Kim, Changick
    • Journal of Broadcast Engineering
    • /
    • v.27 no.1
    • /
    • pp.3-12
    • /
    • 2022
  • Image deblurring aims to remove image blur, which can be generated while shooting the pictures by the movement of objects, camera shake, blurring of focus, and so forth. With the rise in popularity of smartphones, it is common to carry portable digital cameras daily, so image deblurring techniques have become more significant recently. Originally, image deblurring techniques have been studied using traditional optimization techniques. Then with the recent attention on deep learning, deblurring methods based on convolutional neural networks have been actively proposed. However, most of them have been developed while focusing on better performance. Therefore, it is not easy to use in real situations due to the speed of their algorithms. To tackle this problem, we propose a novel deep learning-based deblurring algorithm that can be operated in real-time on HD resolution. In addition, we improved the training and inference process and could increase the performance of our model without any significant effect on the speed and the speed without any significant effect on the performance. As a result, our algorithm achieves real-time performance by processing 33.74 frames per second at 1280×720 resolution. Furthermore, it shows excellent performance compared to its speed with a PSNR of 29.78 and SSIM of 0.9287 with the GoPro dataset.

Effects of Liquid Fertilizer of Application from Rendered Livestock Carcass Residues on Maize Cultivation (랜더링 처리된 가축사체 잔류물로 제조한 액비 시용이 옥수수 재배에 미치는 효과)

  • Jae-Hyuk Park;Se-Won Kang;Jin-Ju Yun;Han-Na Cho;Seung-Gyu Lee;So-Hui Kim;Seong-Woo Choi;Ju-Sik Cho
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.4
    • /
    • pp.236-244
    • /
    • 2022
  • BACKGROUND: Liquid fertilizers can provide nutrients to crops effectively and quickly. Amino acid liquid fertilizers produced by decomposing the residues of rendered livestock carcasses are expected to be effective in improving the productivity and quality of crops. METHODS AND RESULTS: The treatment conditions for maize cultivation were control (Cn), inorganic fertilizer (IF), inorganic fertilizer and rendering residue liquid fertilizer (IF+RALF), compost (CP), compost and rendering residue liquid fertilizer (CP+RALF). Crop productivity, sugar content, and nutrient uptake were investigated after maize harvest in the field applied with liquid fertilizers. Maize yields ranged from 87.6-158 g/plant, and the yield increased by 7.9% and 12.9% in IF+RALF IF+RALF and CP+RALF than in IF and CP, respectively. The maize sugar content increased in the range of 0.1-0.5 brix % by rendering residue liquid fertilizer (RALF) fertilization, and the sugar content was the highest in CP+RALF. There was no significant change in soil chemical properties of the soil due to liquid fertilizer treatment. CONCLUSION(S): RALF increased yield and sugar content in maize cultivation, and fertilization with organic fertilizers was more effective for maize cultivation than inorganic fertilizers. Residues of rendered livestock carcass can be recycled as amino acid fertilizers, which can be effectively used for crop production and quality improvement.

Developing of latent fingerprint on human skin (생체피부에서의 잠재지문 현출)

  • Lee, Hee-Il;Choi, Mi-Jung;Kim, Jai-Hoon;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • On living skin the chances of a successfully developing latent fingerprint are very limited. This is due to the fact that continual perspiration and rapid absorption diffuse into the lipophillic layer on skin. A study was conducted to investigate effectively developing method of latent fingerprints on human skin surfaces and pig skin likely corpse's skin. We used commercial fingerprint powder, black powders, black magnetic powder, fluorescence magnetic powder, Cyanoacrylate fuming (CA) and direct lifting methods (lifting paper, glasses and photo glossy paper). Developing of fresh fingerprints on living skin was achieved with S-powderblack, CA fuming and CA fuming following S-powder, fluorescence powder. The other powder tends to overwhelm the latent print and the background. But, latent fingerprint residue was disappeared with time after deposit on a living surface. In case of pig skin likely corpse's skin, latent fingerprint detection was achieved with CA fuming following S-powder and deposited print during 6 hr at $25^{\circ}C$, 40% relative moisture yielded excellent fingerprints with clear ridge details using 1 min CA fuming. And enhancement of fingerprint detection image using forensic light source was achieved.

Determination of diclofenac and its metabolites in human urine by GC-MS (GC-MS를 이용한 소변 중 Diclofenac 및 대사체 분석)

  • Jeong, Jee-Hye;Huh, Hun;Lee, Won Woong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.510-517
    • /
    • 2008
  • This study has been described the metabolism and excretion in a healthy male urine collected for 26hrs after oral administration of diclofenac. To detect conjugated metabolites of diclofenac, urine sample was acid-hydrolyzed under the conditions of 6M-HCl at over $110^{\circ}C$ for 1hr. During the acidic hydrolysis process, diclofenac and its metabolites were converted into their corresponding lactam-ring through dehydration reaction. As results of chemical conversion by means of hydrolysis, the structures of diclofenac and its metabolites were also changed acidic to basic forms. However, lactam-ring was degraded by hydroxyl ion at basic condition. Thus, the extraction rate of dehydrated diclofenac and its metabolites was not favored at basic condition. For the determination of trace amounts of diclofenac and its metabolites in urine, trimethylsilylation (TMS) with MSTFA was applied and followed by analysis with gas chromatograph-mass spectrometer. In this study, four metabolites that are formed by the hydroxylation of parent drug were mainly detected. Each metabolite was tentatively identified by both interpretation of mass spectra and comparison with previously reported results. In addition, time profile of urinary excretion rate for parent drugs and metabolites was studied. Finally, the metabolic pathway of diclofenac was suggested on the basis of the elucidation of its metabolites and excretion profiles.

A Study on the Relationship between Camera and Subject for Visualization of Image - A Focus on the Status of Watch a Movie with Small Mobile Device - (영상의 시각화를 위한 카메라와 피사체의 상관관계 연구 - 스마트폰 사용자의 영상 시청 현황을 중심으로 -)

  • Ko, Hyun-Wook
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.5
    • /
    • pp.119-126
    • /
    • 2019
  • Watching movies is common on a big screen like a theater or on a big-screen TV. nowadays, small platform such as mobile devices is increasing rapidly for watch a movie. These changes are deeply related to the advent of Internet-based video streaming services such as OTT. OTT's development has provided in free video viewing system without using the set-top box is free from the limitations of time and space. Leading the market is Netflix[1], which started its business with Internet-based DVD rental service. Netflix, which is growing in tandem with the mobile market, had 193.26[2] million members as of the end of 2018. Other OTT participating companies include content-based Pooq, TVing, platform-based Olleh TV Mobile, Oksusu and LTE video portal. The size of such new growth projects has grown gradually, with 25.4 percent of all smartphone users currently watching video content with small mobile devices. Therefore, de-largeization, it is thought that visual language is needed for viewing small mobile devices that are capable of OTT services. To this end, this paper will identify the problem in viewing popular video content with small mobile devices and Survey and study its impact on viewers using the questionnaire.

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.

Real-time Color Recognition Based on Graphic Hardware Acceleration (그래픽 하드웨어 가속을 이용한 실시간 색상 인식)

  • Kim, Ku-Jin;Yoon, Ji-Young;Choi, Yoo-Joo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • In this paper, we present a real-time algorithm for recognizing the vehicle color from the indoor and outdoor vehicle images based on GPU (Graphics Processing Unit) acceleration. In the preprocessing step, we construct feature victors from the sample vehicle images with different colors. Then, we combine the feature vectors for each color and store them as a reference texture that would be used in the GPU. Given an input vehicle image, the CPU constructs its feature Hector, and then the GPU compares it with the sample feature vectors in the reference texture. The similarities between the input feature vector and the sample feature vectors for each color are measured, and then the result is transferred to the CPU to recognize the vehicle color. The output colors are categorized into seven colors that include three achromatic colors: black, silver, and white and four chromatic colors: red, yellow, blue, and green. We construct feature vectors by using the histograms which consist of hue-saturation pairs and hue-intensity pairs. The weight factor is given to the saturation values. Our algorithm shows 94.67% of successful color recognition rate, by using a large number of sample images captured in various environments, by generating feature vectors that distinguish different colors, and by utilizing an appropriate likelihood function. We also accelerate the speed of color recognition by utilizing the parallel computation functionality in the GPU. In the experiments, we constructed a reference texture from 7,168 sample images, where 1,024 images were used for each color. The average time for generating a feature vector is 0.509ms for the $150{\times}113$ resolution image. After the feature vector is constructed, the execution time for GPU-based color recognition is 2.316ms in average, and this is 5.47 times faster than the case when the algorithm is executed in the CPU. Our experiments were limited to the vehicle images only, but our algorithm can be extended to the input images of the general objects.

The Effect of Knee Flexion and Posterior Septal Release on the Location of Popliteal Artery (무릎 굴곡 및 후방 관절낭 절제술이 슬와 동맥의 위치에 주는 영향)

  • Seo, Seung-Suk;Seo, Jin-Hyuk;Kim, Chang-Wan;Kwon, Yong-Wook
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • Purpose: By confirm the change of popliteal arterial position when extension or flexion of the knee and estimate the change of popliteal arterial position after posterior capsular release, we tried to know the position can minimize injury of popliteal artery during arthroscopic surgery and usefulness of posterior capsular release. Materials and Methods: Total of two middle-aged man and woman, fresh frozen cadavers as systemic, all four cases of the knee were included in this study. After the knee was flexed to 0 degrees, 30 degrees, 60 degrees, 90 degrees angle, we estimated distance from posterior tibial cortex to popliteal artery at articular surface, the distal 1 cm and 2 cm from articular surface. We performed posterior capsular release by arthroscopy, and estimated distance between posterior tibial cortex and popliteal artery in the same way. Results: Mean distance between popliteal artery and posterior tibial cortex was 6.3 mm (4.5~7), 4.6 mm (3.6~6), 4.9 mm (3.9~5.8) when knee flexion to 0 degrees at articular surface, distal 1 cm and 2 cm from articular surface each. When knee flexion to 30 degrees, it was 7.4 mm (5.2~9), 4.9 mm (3.6~7.2), 5.3 mm (3.8~6.6). When knee flexion to 60 degrees, it was 8.7 mm (5.4~11), 5.2 mm (4.9~7.3), 6.2 mm (5.4~9.6). When knee flexion to 90 degrees, it was 9.8 mm (5.8~12.1), 5.5 mm (5.1~7.4), 6.5 mm (5.4~10.7). After posterior capsule release, the distance was 6.5 mm (5.5~7.5), 5.8 mm (3.9~7.2), 5.2 mm (3.8~7.0) when knee flexion to 0 degrees, 7.7 mm (5.5~9,1), 7.1 mm (4.6~7.6), 5.5 mm (4.1~6.9) when knee flexion to 30 degrees, 8.9 mm (5.7~11.2), 8.5 mm (5.5~9.2), 6.4 mm (5.3~10.1) when knee flexion to 60 degrees and 10.2 mm (6.3~13.6), 9.5 mm (6.5~11), 6.6 mm (5.9~9.8) when knee flexion to 90 degrees. Conclusion: As knee joint is flexed, the distance from posterial tibial cortex to popliteal artery are increased beween knee joint articular surface and distal 2 cm from knee joint. So popliteal artery injury will be reduced at knee joint surgery. Posterior capsular release could also reduce popliteal artery injury by increasing distance between posterior tibial cortex and popliteal artery.

  • PDF

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.