• Title/Summary/Keyword: 사진계측

Search Result 457, Processing Time 0.024 seconds

Use of Head Posture Aligner to improve accuracy of frontal cephalograms generated from cone-beam CT scans (3차원 콘빔CT 영상에서 형성한 2차원 정모두부방사선사진영상의 정확도 증진을 위한 두부자세재현기의 효과)

  • Sun, Min-Kyu;Uhm, Gi-Soo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.289-299
    • /
    • 2009
  • Objective: The purpose of the present study was to evaluate the effectiveness of the use of Head Posture Aligner (HPA) during cone-beam computed tomography (CBCT) scan in generation of frontal cephalograms using 3D CBCT images. Methods: CBCT scans and frontal cephalograms were made in 30 adult individuals. While a couple of CBCT scan was made for one subject, one was made with conventional method, without use of HPA, the other was acquired with the use of HPA. After creation of virtual frontal cephalogram from each 3D CBCT image, it was traced and compared with the tracing of real frontal cephalogram. Results: In the comparison of the measurements, the virtual cephalograms with the use of HPA did not show statistically significant differences with the real cephalograms whereas the virtual cephalograms without the use of HPA presented significant differences with real cephalograms in many measurements. In the correlation analysis with the measurements of the real cephalograms, the virtual cephalograms with the use of HPA showed higher correlations in all measurements than the virtual cephalograms without the use of HPA. Conclusions: Measurements from CBCT-generated cephalograms become similar to those from real cephalograms with the use of HPA during CBCT scan. Thus, the use of HPA is suggested during the CBCT scan in order to construct accurate virtual frontal cephalograms using 3D CBCT images.

A cephalometric and dental cast study of obstructive sleep apnea patients (폐쇄성 수면 무호흡 환자의 측모 두부방사선계측사진 및 치아모형 연구)

  • Jung, Mi-Ra;Nam, Ki-Young;Kim, Jong-Bae;Kwon, Oh-Won;Hwang, Sang-Hee
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.228-236
    • /
    • 2006
  • To evaluate the cephalometric and dental characteristics of obstructive sleep apnea (OSA) patients, 23 OSA patients and 15 control, non-OSA, patients who visited the Sleep Disorder Clinic Center, Keimyung University were investigated. Patients who suffered from apnea-hypopnea episodes over 10times per hour were diagnosed as having OSA after polysomnograph testing, Impressions were taken with alginate. Cephalometric radiographs were taken at maximum intercuspation. The dental cast measurements, including transpalatal width, intercanine width, intermolar width and palatal depth did not differ between the control and OAS groups and did not have a positive correlation with the apnea-hypopnea index (AHI). Upper airway width was statistically narrower than the control group. Upper airway width had a low negative correlation with AHI, but, lower airway width had a low positive correlation, and, the higher the AHI score, the longer the mandibular border to hyoid distance.

Investigation of ground behaviour between plane-strain grouped pile and 2-arch tunnel station excavation (2-arch 터널 정거장 굴착 시 평면변형률 조건에서 군말뚝의 이격거리에 따른 지반거동 분석)

  • Kong, Suk-Min;Oh, Dong-Wook;Ahn, Ho-Yeon;Lee, Hyun-Gu;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.535-544
    • /
    • 2016
  • Special tunnel design and construction methods have been suggested due to developments of subway and tunnel. Collapse accidents of tunnel bring enormous damage. So, observation and analysis for the safety of tunnelling and behaviour of surrounding ground are important. But, it is not economical to implement the field test in every time. Therefore, this study has measured ground behaviour due to excavation of 2-arch tunnel station according to offset between grouped pile and tunnel by laboratory model test. For the model test, trapdoor device was adopted. Tunnelling is simulated by volume loss of 2-arch tunnel. Ground displacements are observed by close range photogrammetric method and image processing. In addition, these data are compared with numerical analysis.

Lateral Cephalometric Measurements of Class I Malocclusion Patients with Uncertainty (불확도를 고려한 Class I 부정교합 환자의 측방두부방사선영상 계측값)

  • Lee, Ji Min;Song, Ji-Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Hojae;Cho, Hyo-Min;Shin, Teo Jeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.65-74
    • /
    • 2018
  • The aim of this study was to obtain the traceability of the software used to analyze lateral cephalometry and to calculate the uncertainty of the measurements. Furthermore, this study aimed to provide a basis for obtaining standard references for measurement values for orthodontic treatment in children. Cephalometric data were collected from 100 children diagnosed with class I malocclusion between the ages 6 to 13 years who visited the pediatric dentist at Seoul National University Dental Hospital. To ensure traceability, a phantom device was created. Correction values were calculated by measuring the length and angle of the phantom device using the software. Type A uncertainty was calculated by obtaining the standard deviation of cephalometric measurements of 100 persons and the standard error of repeated measurements. Determination of the type B uncertainty was induced by minimum resolution and the position of the head. Using these, the combined standard uncertainty was obtained and the expanded uncertainty was calculated. The results of this study confirm that the currently used software has high accuracy and reliability. Furthermore, the uncertainty of orthodontic measurements in Korean children aged 6 to 13 years was calculated, and distribution range for class I malocclusion with 95% confidence interval was suggested.

Accuracy of Automatic Cephalometric Analysis Programs on Lateral Cephalograms of Preadolescent Children (소아 환자 대상의 자동 계측점 식별 프로그램의 정확성 평가)

  • Song, Min Sun;Kim, Seong-Oh;Kim, Ik-Hwan;Kang, Chung-min;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.245-254
    • /
    • 2021
  • The aim of this study was to evaluate the accuracy of 3 different automatic landmark identification programs on lateral cephalgrams and the clinical acceptability in pediatric dentistry. Sixty digital cephalometric radiographs of 7 to 12 years old healthy children were randomly selected. Fourteen landmarks were chosen for assessment and the mean of 3 measurements of each landmark by a single examiner was defined as the baseline landmarks. The mean difference between an automatically identified landmark and the baseline landmark was measured for each landmark on each image. The total mean difference of 3 automatic programs compared to the baseline landmarks were 2.53 ± 1.63 mm. Errors among 3 programs were not significantly different for 12 of 14 landmarks except Orbitale and Gonion. The automatic landmark identification programs showed significant higher mean detection errors than the manual method. The programs couldn't be used as the 1st tool to replace human examiners. But considering short consuming time, these results indicate that all 3 programs have sufficient validity to be used in pediatric dental clinic.

Validity of midsagittal reference planes constructed in 3D CT images (전산화단층사진을 이용한 3차원 영상에서 정중시상기준평면 설정에 관한 연구)

  • Jeon, Ye-Na;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.182-191
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the validity of midsagittal reference (MSR) planes constructed in maxillofacial 3D images. Methods: Maxillofacial computed tomography (CT) images were obtained in 36 normal occlusion individuals who did not have apparent facial asymmetry, and 3D images were reconstructed using a computer software. Six MSR planes (Cg-ANS-Ba, Cg-ANS-Op, Cg-PNS-Ba, Cg-PNS-OP, FH${\perp}$(Cg, Ba), FH${\perp}$(Cg, Op)) were constructed using the landmarks located in the midsagittal area of the maxillofacial structure, such as Cg, ANS, PNS, Ba and Op, and FH plane constructed with Po and Or. The six pairs of landmarks (Z, Fr, Fs, Zy, Mx, Ms), which represent right and left symmetry in the maxillofacial structure, were selected. Statistically significant differences of the right and the left measurements were examined through t-test, and the difference of the right and the left measurement was compared among the six MSR planes. Results: The distances from the right and the left landmarks in each pair to each MSR plane did not show a statistically significant difference. The reproducibility of the landmark identification was excellent. Conclusion: All the six planes constructed in this study can be used as a MSR plane in maxillofacial 3D analysis, particularly, the planes including Cg and ANS.

Analysis of Digital Vision Measurement Resolution by Influence Parameters (디지털 영상 계측 기술의 영향인자에 따른 정밀도 분석)

  • Kim, Kwang-Yeom;Kim, Chang-Yong;Lee, Seung-Do;Lee, Chung-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.109-116
    • /
    • 2007
  • This study has reviewed the applicability of displacement measurement by using a digital vision technique based on typical photogrammetric methods. In this study, a series of experimental measurements have been performed in order to improve the accuracy of digital vision measurement by establishing criteria of factors of various vision measurements. It is found that the digital vision measurement tends to show higher accuracy as the image size(resolution) and the focal length become larger and the distance to an object becomes closer. It is also observed that measurement error decreases with processing as many images as possible in various angles. Applicability on high-resolution displacement measurement is proved by applying the digital vision measurement developed in this study to a large scale loading test of concrete lining.

A Recording System For Nuclear Radation Detection by Means Of Circular Radial Deflection (원형방사상편향에 의한 방사능계측용 기록장치)

  • 이희용
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 1966
  • In this article, a recording system for nuclear radiation detection by means of circular radial deflection as an instrument and its applications are described. In the electronic circuit of the instrument, the linearity of a deflected pulse on a circular sweep is especially contribed by employing a multiplying circuit, not to mention the one of a circular time base itself. A sequence of random pulses was recorded on a circular sweep of the CRT screen by means of one cycle unblanking due to a logic circuit. It seems that the intrument is suitable for measuring a decay curve of a short-lived nuclide and its pulse spectrum

  • PDF

A COMPARATIVE STUDY OF XERORADIOGRAPHIC CEPHALOMETRY WITH CONVENTIONAL CEPHALOMETRY (건성방사선 두부계측사진과 기존방사선 두부계측 사진과의 비교연구)

  • Lee Hie-In;Yoon Jung-Ho
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.127-135
    • /
    • 1991
  • This study purports to make in consideration of the recent xeroradiographic development an exact analysis, by comparison, of conventional cephalometry and xeroradiographic cephalometry that are indispensably utilized in the field of orthodontics as a means of cephalometric measuring For that purpose attached to ten landmarks on a dry skull was a lead ball, a radio-opaque substance, and projected X-ray beam one time each by means of the two methods, and then ten times each without change of locations of the skull, in the state in which the lead ball was removed. These data were committed to ten dentists for tracing to determine a difference between the same kind of cephalometries. A computerized statistic analysis of the data shows findings, as follows: 1. Conventional cephalometry shows higher accuracy in Nasion, as compared with xeroradiographic cephalometry. 2. Xeroradiographic cephalometry is found more accurate in Anterior Nasal Spine, 'A' Point, Pogonion, Gonion, Porion, Prosthion and Orbitale than conventional cephalometry. 3. There is no difference between both methods in Basion. 4. At test between the two methods by all the dentists reveals that xeroradiographic cephalometry is more accurate than conventional cephalometry.

  • PDF