• Title/Summary/Keyword: 사위(융합제거)

Search Result 6, Processing Time 0.017 seconds

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

The Relationship Fixation Disparity between Associated Phoria (주시시차와 각비정시의 관계)

  • Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • In order to have a comfortable vision without any asthenopia in work place, it is very necessary to make a complete binocular correction in addition to the perfect correction of refractive deficits. For this, At first, the exact understanding of the required corrective value of the existing angular ametropia(associated phoria) is needed. The fact likely seems fact that a correction of refractive deficits could not to be reached with single optotype, the corrections of angular ametropia(associated phoria) with single optotype is impossible. The reason is that a most ametropia(associated phoria) is accompanied with the fixation disparity. To make a perfect measurement of ametropia(associated phoria), at least, 3 kinds of optotype is essential. This fact could be explained by stating the fusional stimulus in the binocular refraction tests on each eye. If these types of three tests have not practical practice. The most of many cases may result in undercorrection.

  • PDF

A Correlation Between Vertical Fixation Disparity and Stereopsis at Near (근거리에서 수직주시시차와 입체시와의 관계)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2013
  • Purpose: To investigate a correlation between vertical fixation disparity and stereopsis by analyzing distribution of types of vertical fixation disparity. Methods: In this study, RANDOT(R) stereotest partly using random dot was used in stereopsis tests. The vertical fixation disparity in close proximity categorized fixation disparity slope into six types on the basis of the result of measurement in when two thin lines, one for one eye looks, become overlapped as a line by adding into prism with Wesson fixation disparity card while maintaining a distance of 25 cm from patients. Results: In the types of near vertical fixation disparity curve, targeting 43 people, the first type 55.82% was the most distributed, the second type is the least 23.25%, the third type of 4.65%, the fourth type of 4.65%, the fifth type of 6.98%, the sixths types of 4.65% were distributed. The result of a correlation analysis, which shows the degree of linear correlation between two variables, represented that stereopsis is not correlated with Y-intercept (r = -0.07) which show vertical fixation disparity, associated phoria (r = -0.03) and dissociated phoria (r = -0.00), but it was not statistically significant (p>0.05). Fixation disparity slope of vertical fixation disparity (r = 0.36) was shown to have a positive correlation with stereopsis. It has a low positive correlation and a meaningful statistics (p<0.05). The Y-intercept which indicates vertical fixation disparity was also not associated with stereopsis (r = -0.07) and dissociated phoria (r = -0.03), and this was not statistically significant (p>0.05), while it had a high correlation as well as a statistically significant with associated phoria (r = 0.89). There was a negative correlation between Y-intercept and fixation disparity slope of vertical fixation disparity (r = -0.33). It showed a low relationship but statistically valuable (p>0.05). As a result of regression analysis, the stereopsis was changed as 7.631" if vertical fixation disparity changes 1' and the vertical fixation disparity changed as 0.017' if stereopsis changes 1', and the change was statistically significant (p<0.05). Conclusions: The study shows that there is a low correlation between stereopsis and vertical fixation disparity, and it is difficult to determine stereopsis only using vertical fixation disparity. Therefore, it suggests other factors above vertical fixation disparity have greater influence on stereopsis.

The Change After Visual Training of Forced Vergence Fixation Disparity Curve (강제vergence 주시시차곡선의 시기능훈련 후의 변화)

  • Choi, Sun-Mi;Lee, Ki-Young;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.539-550
    • /
    • 2014
  • Purpose: This research was designed to figure out if there are changes based on types of vergence fixation disparity curve after optical correction and vision training to for people with steep slope of forced vergence fixation disparity curve and symptoms. Methods: For 30 subjects out of 91 subjects, who have steep slopes of fixation disparity curve examined with Wesson Fixation Disparity Card and symptoms about steep slope of fixation disparity curve, proper vision training was offered for 5 weeks. Results: After Vision training for 30 people with the symptoms of type I, II, III, IV for 5 weeks, slope of fixation disparity curve was significantly changed (p=0.013), and the results of binocular vision test and subjective symptoms were also significantly improved. Conclusions: Vision training can not only affect the change of fixation disparity curve, but also relieve the symptoms. Fixation disparity curve has lots of visual function information of the subject and can be suggested as a guideline for prescribing.