• Title/Summary/Keyword: 사무소건물

Search Result 126, Processing Time 0.028 seconds

Fuzzy Hybrid Control of a Smart TMD for Reduction of Wind Responses in a Tall Building (초고층건물의 풍응답제어를 위한 스마트 TMD의 퍼지 하이브리드제어)

  • Kim, Han-Sang;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2009
  • Fuzzy hybrid control technique with a smart tuned mass damper(STMD) was proposed in this study for the suppression of wind-induced motion of a tall building. To develop the effective control algorithm for a STMD, skyhook and groundhook control algorithms were employed. Usually, skyhook controller can effectively reduce STMD motion and groundhook controller shows good control performance for the reduction of building responses. In this study, fuzzy hybrid controller, which can determine an optimal weighting factor for combining two controllers in real time, was developed to improve the control performance of conventional hybrid controller using weighted sum approach. A 76-story office building was used as an example structure to investigate the performance of the proposed controller. A magnetorheological(MR) damper was used to develop a STMD and the control performance of STMD was evaluated comparing with the passive and active TMD. The numerical studies show that the control effectiveness of a STMD is significantly superior to that of the conventional TMD. It is also shown that fuzzy hybrid controller can effectively adjust skyhook and groundhook control algorithms and reduce both responses of STMD and building.

Structural Performance of Beam-to-Column Joint Types in Dapo-style Buildings of the Joseon Dynasty (조선시대 다포계 건축물의 결구형태별 구조성능 평가)

  • Yoon, Jeong-Hoon;Choi, Yun-Chul;Lee, Eun-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.8-14
    • /
    • 2019
  • In Korean traditional wooden architecture, joint performance varies with the material characteristics of timber, the form of joint, the precision of timber-trimming and the like. Case studies prove that the beam-to-column joint type has large influence on the degrees of deformation and spacing. This is not only true of single-story buildings, but also of large-scale multi-story buildings more apparently. Therefore, this study followed the process of examining to joint types, producing their specimens and testing their structural performance. As a consequence of structural test, the dovetail joint specimen showed the best outcomes of the maximum load and rigidity. Synthesizing the structural performances by respective forms of joints, the Doraegeoji dovetail joint specimen showed the higher performance, followed in order by the Doraegeoji mortise joint specimen and the Tongneoko dovetail joint specimen. The structural performance of a building varies with the characteristics by the shouldering forms of penetrating beams and with the joint types within the columns. This should be considered for the new construction or restoration of multi-story buildings, and be continuously researched henceforth.

A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building (사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석)

  • Seo, Byeong-Mo;Yu, Byeong-Ho;Lee, Kwang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building (사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석)

  • Seo, Byeong-Mo;Son, Jeong-Eun;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

A Competitive Advantage Analysis of Construction Duration through the Comparison of Actual Data of Domestic Construction Firms - Focused on Mix-Use Residential Building and Officetel Building - (건설사별 공기비교를 통한 공기경쟁력 분석 - 주상복합 및 오피스텔 건물을 중심으로 -)

  • Ryu, Han-Guk;Kim, Sun-Kuk;Lee, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.1 s.29
    • /
    • pp.138-147
    • /
    • 2006
  • Construction companies have been interested in the construction duration which importantly affects the performance and the success of the construction projects in accordance with the systemic changes such as five days per week system, introduction of construction duration reduction bidding system and post sale system nowadays. It is also very important to estimate and forecast properly the construction duration as the construction companies compete for the projects in the situation of construction market reduction and the lowest bidding system. Recognizing the importance about the construction duration, the researches about comparing and analyzing or estiamting the construction duration have been performed. However, comparing studies about the construction duraion have been limited to the apartment and office building in domestic area. Many studies about forecasting construction duration have been performed through stochastic analysis and simulations. Little research has been addressed the comparison analysis of the real construction duration about the mix-use building and officetel building which occured according to the changes of the building requirements. Therefore, the objective of this study is to compare and analyze the real construction duration and the hypothetical construction duration about the mix-use building and officetel building of the domestic companies. Moreover, we select the most competitve construction company to get the strengths and analyze the competitive advatages of the construction companies about construction duration.

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building (사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구)

  • Son, Chang-Hee;Yang, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

현상설계경기 - 판문점 '자유의 집'

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.8 s.328
    • /
    • pp.102-107
    • /
    • 1996
  • 판문점 '자유의 집' 설계경기 결과가 지난 6월 20일 공식 발표되었다. 조달청이 통일원의 '자유의 집' 개축 결정에 따라 지난 1월 설계를 공모하고 3월 29일까지 총 12개의 작품을 접수받은 결과 주.담건축(오평국)의 안이 당선작으로 선정되었으며, 주.모양건축(곽동희), 한메건축(이충기)안이 우수작으로 선정되었다. 이번 설계경기의 심사는 정명현(홍익대 심사위원장), 이선구(숭실대), 조대성(성균관대), 이호진(건국대)교수와 이준구(남북회담 사무국 실장)씨 등 5명이 맡았다. 당선된 주.담건축의 인은 자유의 집이라는 건물의 특성에 부합하도록 통일을 소망하는 의미로 두 손을 합장한 형태로 하였으며, 지붕은 강토를 수호한다는 취지로 방패연 모양을 형상화하였다. 1층에는 남측출입구와 이산가족 면회실이, 2층에는 남북통로 및 회의실, 3층에는 남북연락사무소와 다목적 예비실, 4층에는 90층 규모의 전망대가 위치할 예정이다. 오는 7월 실시설계안이 확정되면 97년쯤이면 판문점 자유의 집이 통일의 소망을 안고, 단아하고도 힘 있는 모습으로 자리잡을 것이다.

  • PDF

A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building (투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구)

  • Yim, Sang-Joon;Seo, Hye-Soo;Kim, Byung-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

The Work Scope of Remodelling for the Intelligent Office Building (기존 사무소건축의 IB화를 위한 리모델링 작업범위)

  • Park, Keun-Joon;Koo, Soo-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.75-83
    • /
    • 2004
  • The IB is normally defined in terms of BA, OA, security system, information processing and telecommunications services However, the buildings being already in existence are deficient in two areas. One of these areas is building envelope and plan. The other area is mechanical, electrical and structural systems which do not provide the environmental quality required by IB. Existing technology and design knowledge are available to address these deficiencies. Especially, the office buildings being already in existence must meet IB requirement in order to achieve desirable office environment. They are a building envelope, moisture control, properly-located windows, shafts for duct, telephone and electric closets and acoustical environments. In this paper, a new approach to construct the work scope of remodelling the office building being already existence is described by contrasting the building performance criteria of IB. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.