Comparison of Cooling-Energy Performance Depending on the Economizer-Control Methods in an Office Building (이코노마이저 제어 방법에 따른 사무소 건물의 냉방 에너지 성능 비교)

  • Son, Jeong-Eun;Hyun, In-Tak;Lee, Jea-Ho;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.432-439
    • /
    • 2015
  • Current building procedures seek to minimize external air supplies to reduce the energy consumption of air conditioning, resulting in a high dependency on mechanical ventilation. We therefore studied an economizer-cycle system, whereby the introduction of external air saves energy. We analyzed different economizer-control methods, addressing mixed-air temperatures and outdoor-air fractions according to outdoor-air temperatures; also, we analyzed the energy consumption of the three economizer-cycle control types using detailed EnergyPlus simulation modeling. A differential enthalpy control method showed a lower energy consumption range from 5.8% to 6.2% than that of other methods during the simulated period. A differential dry-bulb control method showed a 12.7% lower energy consumption than the no-economizer method in the intermediate period, but also showed 7.1% more energy consumption during the summer period. When latent heat was not removed due to high summer humidity, we found a significant level of resultant energy consumption.

A Design of Photosensor Shape Considering Change of Room Situations for the Daylight Responsive Dimming Systems (광센서 조광제어시스템의 재실변화를 고려한 광센서 형상 디자인)

  • Joo, Keun-Tak;Park, Byung-Chul;Choi, An-Seop;Kyung, Chil-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.1-8
    • /
    • 2005
  • Daylight responsive dimming systems have been used to save the energy in office buildings. It is needed to consider a configuration of photosensor shape for efficient management of daylight responsive dimming systems. The configuration of optimal photosensor shape must be able to measure the exact luminous flux without changing of setting positions corresponding to the changes of room situations. On this occasion optimal photosensor shape must be designed with configuration of a proper photosensor spatial distribution and location for the daylight responsive dimming systems.

A Study on the Methodology of Building Energy Consumption Estimation and Energy Independence Rate for Zero Energy City Planning Phase (제로에너지시티 계획을 위한 건물에너지 수요 예측 방법론 개발 및 자립률 산정에 대한 연구)

  • Bae, Eun-ji;Yoon, Yong Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.29-40
    • /
    • 2019
  • In response to the rapid climate change, in order to save energy in the field of buildings, the country is planning not only zero energy buildings but also zero energy cities. In the Urban Development Project, the Energy Use Plan Report is prepared and submitted by predicting the amount of energy demand at the planning stage. However, due to the activation of zero-energy buildings and the increase in the supply of new and renewable energy facilities, the energy consumption behavior of buildings in the city is changing from the previous ones. In this study, to estimate urban energy demand of Zero Energy City, building energy demand forecasts based on "Passive plans for use of energy based primary energy consumption", "Actual building energy usage data from Korea Appraisal Board" and "data from Certification of Building Energy Efficiency Rating" as well as demand forecast according to existing "Consultation about Energy Use Plan Code" were calculated and then applied to Multifunctional Administrative City 5-1 zone to compare urban total energy demand forecasts.

Optimizing the Life Cycle Cost of a Solar Water Heating System in an Office Building Through Simulation (사무소건물 태양열급탕시스템의 LCC 최적화 시뮬레이션)

  • Ko, Myeong-Jin;Choi, Doo-Sung;Chang, Jae-D.;Kim, Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.859-866
    • /
    • 2010
  • This study examined the economics of a solar water heating system for an office building using life cycle cost (LCC) optimization simulations. The numerical simulations were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm. The solar collector area, slope, mass flow rate per collector area and storage tank volume were selected as the main design parameters of the solar water heating system. The LCC optimization simulations of the system were carried out for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the collector area could be decreased by 17% and 28%, storage tank volume could be decreased by 49% and 54%, and mass flow rate per collector area increased by 5% and 9% respectively compared to a non-optimized system. The LCC of the system was reduced by 4% for $60^{\circ}C$ and 7% for $50^{\circ}C$. The initial installation cost of the system was reduced by 24% for $60^{\circ}C$ and 34% for $50^{\circ}C$. However, the operating cost of the system increased by 16% for $60^{\circ}C$ and 36% for $50^{\circ}C$ compared to a traditional solar water heating system.

Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing (축소모델실험에 의한 철근콘크리트 3층 보통모멘트골조의 구조 성능 평가)

  • Han Sang-Whan;Kwon Gun-Up
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.673-678
    • /
    • 2005
  • ACI 318 (1999) defines three types of moment frames: Ordinary Moment Resisting Concrete Frame (OMRCF), Intermediate Moment Resisting Concrete Frame (IMRCF), and Special Moment Resisting Concrete Frame (SMRCF). OMRCF is the most popular type of moment frame in mild seismic zones that requires the least detail and design requirements. This study focuses on the seismic performance of Ordinary Moment Resisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose a 3-story OMRCF was designed in compliance with the minimum design requirements in ACI 318 (1999). An one third 3 story specimen was made and tested. For scaled model, the similitude law of true replica was applied. The specimen was loaded with quasi-static reversed cyclic lateral loading. The overall behavior of OMRCF is quite stable without abrupt strength degradation. It is found that tested frame has the base shear strength larger than the design base shear for seismic zone 1, 2A and 2B calculated using UBC 1997.

Fuzzy Hybrid Control of Semi-active TMD (준능동 TMD의 퍼지 하이브리드 제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.433-436
    • /
    • 2009
  • 본 연구에서는 준능동 TMD(STMD)가 설치된 초고층건물의 풍응답을 효과적으로 저감시키기 위한 퍼지 하이브리드제어기법을 제안하였다. 이를 위하여 STMD의 응답저감에 우수한 성능을 보이는 스카이훅(skyhook) 제어기와 구조물의 응답저감에 뛰어난 그라운드훅(groundhook) 제어알고리즘을 사용하였다. 본 연구에서는 두 제어기를 적절히 조합하기 위하여 최적의 가중치를 실시간으로 결정하는 퍼지 하이브리드제어기를 개발함으로써 일반적인 가중합방식의 하이브리드 제어기법의 성능을 개선하였다. 제안된 제어기의 성능을 검토하기 위하여 풍하중을 받는 76층 사무소 건물을 예제구조물로 사용하였다. MR 감쇠기를 이용하여 STMD를 구성하였고 STMD의 제어성능을 평가하기 위하여 TMD 및 ATMD의 성능과 비교하였다. 수치해석을 통하여 STMD의 제어성능이 TMD에 비하여 월등히 뛰어남을 확인할 수 있었다. 또한 퍼지 하이브리드 제어기법을 사용하면 스카이훅 및 그라운드훅 제어기를 효과적으로 조합하여 STMD와 건물의 응답을 동시에 줄일 수 있음을 확인하였다.

  • PDF

COMPARISON OF THE EFFECTS OF THERMAL MASS EXTERIOR WALLS ON HEATING AND COOLING LOADS IN COMMERCIAL BUILDINGS - Evaluation of Delta Load Concept Used in The Draft Standard ASHRAE 90. 1 - (상업용 건물에 있어서 외벽의 축열용량이 난방부하에 미치는 영향 연구 - ASHRAE Standard 90. 1안에서 사용된 Delta Load 개념의 평가 -)

  • Park, Sang-Dong;Kusuda, Tamami
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.372-379
    • /
    • 1986
  • 본고는 상업용 건물에 있어서의 냉난방부하에 대한 외벽의 축열(열용량)효과를 비교$\cdot$분석하는데 그 목적이 있다. 가장 최근에 발표된 에너지 해석 프로그램인 DOE-2.1C를 이용하여 Berkeley Solar Group (BSG) 이 제안한 축열효과를 분석하였다. 본 고에서의 축열효과는 "delta load"로서 표현되어 있으며 "delta load"는 전형적인 나무구조 건물과 벽돌조 건물의 연간 냉난방부하의 차이로서 표시된다. BSG 보고서에 의하면 delta load는 (1)구조물의 위치와 관련한 단열방법 (2)벽의 열용량 (3)벽의 열관류을 (4)기후조건에 따라 달라진다고 되어 있다. 본 고에서의 delta load 계산은 중규모 사무소 건물을 대상으로 하였으며 Lake Charles, LA와 Madison, WI 기후 데이터를 사용하였는데 DOE-2.1C 사용에 의한 delta load는 BSG의 결과와 일반적으로 잘 조화가 되는 것으로 나타났으나 외주부의 방향에 따른 dalta load와 난방에 있어서는 다소 큰 차이를 보여 주고 있으며, 외단열과 중간열의 효과는 BSG의 결과와 마찬가지로 비슷하였다.

  • PDF

Artificial Lighting Energy Saving by Daylighting in Office Building (사무소건물에서 자연채광에 의한 조명에너지 절약의 평가)

  • 임병찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.608-613
    • /
    • 2004
  • Artificial lighting accounts for a significant portion of the energy use in office buildings. Therefore, daylighting is considered one of the fundamental design features of energy-efficient buildings. However, complex daylighting simulation tools are not suitable for most designers to help in the decision-making process. This paper provides the results of a simulation analysis to determine the potential energy savings of daylighting effects reducing electrical energy consumption for office building. A whole building simulation tool is used to determine the effects of daylighting on lighting electricity use as well as total electricity use for typical office buildings. It was determined that daylighting does not provide significant additional lighting energy savings when glass transmittance is increased over 0.7 A simplified method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.

An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea (국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析))

  • Byun, Gye-Sung
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

Ventilation and energy performance evaluation of the office building with variable air volume system (변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가)

  • Kwon, Y.L.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF