• Title/Summary/Keyword: 사각공동

Search Result 30, Processing Time 0.022 seconds

Reduction of the Cavity Flow Oscillations at Supersonic Speeds (초음속 공동유동에서의 진동감소)

  • Kang, Min-Sung;Shin, Choon-Sik;Kwon, Joon-Kyung;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.345-348
    • /
    • 2008
  • The subcavity passive control technique is used in present study. Cavity-induced pressure oscillation has been investigated numerically for a supersonic three-dimensional flow over rectangular cavities at Mach number 1.83 at the cavity entrance. The three-dimensional, compressible Navier-stokes equations are numerically solved based on a fully implicit finite volume scheme. The results showed that the resultant amount of attenuation of cavity-induced pressure oscillations was dependent on the length and thickness of the flat plate.

  • PDF

Heat Transfer in an Axisymmetric Cavity of a Rectangular Tube (사각관로의 축대칭 공동부에서의 열전달)

  • Park, Yong-Il
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 1990
  • An experimental study for the flow in an axisymmetric cavity of rectangular tube was performed. The pressure and heat transfer coefficient along the side and opposite-walls of the cavity were measured. The cavity length was varied from 80mm to infinity during the experiment. As the result of this study, it was found that as the length of cavity increased beyond the reattachment point, the heat transfer coefficient decreased. It was also found that the mean heat transfer coefficient became maximum near the reattachment point.

  • PDF

Effect of Adiabatic Sidewalls on Natural Convection in a Rectangular Cavity (사각공동내 자연대류에서 측면 단열벽에 의한 영향)

  • Heo, Jeong-Hwan;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.825-834
    • /
    • 2010
  • In this study, we investigated the effects of adiabatic walls on natural convection in various rectangular cavities experimentally and numerically. Heat transfer rates were measured for cavities with and without adiabatic sidewalls by varying Grashof number from $1.53\times10^7$ to $1.01\times10^{10}$. Some typical test results were successfully simulated using FLUENT. In the case of very narrow cavities, where the adiabatic walls were very close to each other, it was difficult to perform experiments; therefore, FLUENT simulations were performed. The existing heat transfer correlations for rectangular cavities were well predicted by the experimental and numerical results. As expected, the effects of adiabatic walls were restricted to the very narrow region near the walls. This study was carried out during the development of an analogy experimental method in which heat-transfer systems are replaced with mass-transfer systems using copper sulfate electroplating systems. The results of this study provide theoretical background of handling adiabatic walls during the design of test facilities.

Pool Boiling Characteristics on the Microstructured surfaces with Both Rectangular Cavities and Channels (사각 공동 및 채널이 형성된 마이크로 구조 표면에서의 수조비등 특성연구)

  • Kim, Dong Eok;Park, Su Cheong;Yu, Dong In;Kim, Moo Hwan;Ahn, Ho Seon;Myung, Byung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.383-389
    • /
    • 2016
  • Based on a surface design with rectangular cavities and channels, we investigated the effects of gravity and capillary pressure on pool-boiling Critical Heat Flux (CHF). The microcavity structures could prevent liquid flow by the capillary pressure effect. In addition, the microchannel structures contributed to induce one-dimensional liquid flow on the boiling surface. The relationship between the CHF and capillary flow was clearly established. The driving potentials for the liquid supply into a boiling surface can be generated by the gravitational head and capillary pressure. Through an analysis of pool boiling and visualization data, we reveal that the liquid supplement to maintain the nucleate boiling condition on a boiling surface is closely related to the gravitational pressure head and capillary pressure effect.

Study on the blind zone of social service in Korea (한국 사회서비스의 사각지대 실태)

  • Noh, Hyejin
    • Korean Journal of Social Welfare Studies
    • /
    • v.47 no.1
    • /
    • pp.179-204
    • /
    • 2016
  • The purpose of this study is to establish the concept of the blind zone of social services and analyzing the conditions by children, the elderly, the disabled, and the poor. This study used the raw data of demand/supply of social service and sample size is 4,038. Results of the study were as follows. First, in terms of the coverage, the biggest blind zones of social service are the employment support and cultural service. These results were similar for all households. But, it is noteworthy that the size and proportion of blind zones of housing support services for children, counseling services for elderly are relatively big. Second, in terms of adequacy, the most serious blind zones of social service are health and the employment support service. Especially, the elderly, the disabled, and the poor are not the most adequate adult care services and children are community service. Based on such findings, this study suggests expansion of employment support services and health care, monitoring for the services analyzed to be over-supply, and intensive involvement of private sectors about the services provided by the government of a large blind zone.

Evaluation of the Structural Performance of Tetragonal Lattice Girders (사각 격자지보의 구조 성능 평가)

  • Kim, Seung-Jun;Han, Keum-Ho;Won, Deok-Hee;Baek, Jung-Sik;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.267-278
    • /
    • 2012
  • In general, the H-shaped steel ribs or triangular lattice girders have been mostly used in constructing tunnels through the NATM construction method. The H-shaped steel rib has higher flexural and axial strength than the triangular lattice girder, but many unexpected gaps can occur in the concrete lining system after shotcreting if the H-shaped steel rib is used as the support system. To achieve better shotcreting quality, the triangular lattice girder was developed. However, in general, the triangle lattice girder has low flexural and axial strength. Likewise, the triangular lattice girder, which has circular sectional members, has so many fractures from welded points at the joints between the members. Finally, the new type of tetragonal lattice girder was developed to overcome those problems. In this study, the structural performance of the tetragonal lattice girders was evaluated through analytical and experimental studies. In the analytical studies, the four-point bending analysis, the traditional evaluation method to determine the flexural strength of the lattice girder, was performed. Moreover, the linear-elastic analysis and stability analysis of the arch structure made by the lattice girders were performed to measure structural performance. Experiments were likewise performed to compare the structural performances of the tetragonal girder with traditional triangular lattice girders.

Mesh slide for preventing fall(building, APT etc.) (추락방지 매쉬형 슬라이드)

  • Yang, Seung_gyu;Kwon, Young_hyuk
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.270-271
    • /
    • 2015
  • 본 논문은 추락 방지장치가 형성된 창문에 관한 것으로, 일반적인 형태의 공동주택 여닫이 창문은 사각틀 형태로 된 창틀의 내 창문이 슬라이드 가능하게 끼워져 있고, 창문을 개방 시, 창틀에 해충방지용 방충망이 설치되어 있지만, 종래의 방충망은 구조적으로 매우 취약하여 찢어지거나 휘면서 창틀로부터 쉽게 이탈되어 쉽게 추락사고가 발생하였다. 이러한 문제점을 해소하기 위해서 본 기술을 적용한 창문 설치 시, 개방했을 경우에만 체인 안전망이 형성되고, 창문을 닫았을 경우에는 체인 안전망이 창틀 또는 창문틀에 수용되어 보이지 않게 되어 미관을 해치지 않으면서도 추락 사고를 방지하여 안정성을 보장하는 효과를 거두었다.

  • PDF

Experimental/ Computational Study on the Passive Control of Supersonic Cavity Flow using a Sub-Cavity (Sub-cavity를 이용한 초음속 cavity 유동의 피동제어에 대한 실험 및 수치해석적 연구)

  • Lim, Chae-Min;Lee, Young-Ki;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.295-298
    • /
    • 2007
  • The effectiveness of passive control techniques for reducing the pressure oscillation generated in a supersonic cavity flow was investigated numerically and experimentally, respectively. The control device includes a sub-cavity installed in the upstream edge of a rectangular cavity. Time-dependent supersonic cavity flow characteristics with turbulent features were examined by using the three-dimensional, mass-averaged Navier-Stokes computation based on a finite volume scheme and large eddy simulation. The results show that the pressure oscillation near the trailing edge dominates overall time-dependent cavity pressure variations. Such an oscillation can be attenuated more significantly in the presence of the sub-cavity compared with the cavity without sub-cavity, and a larger sub-cavity leads to better control performance.

  • PDF

A Finite Element Analysis of Conjugate Heat Transfer Inside a Cavity with a Heat Generating Conducting Body (고체 열원이 존재하는 공동 내의 복합열전달 문제의 유한요소해석)

  • Ahn, Young-Kyoo;Choi, Hyoung-Gwon;Yong, Ho-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.170-177
    • /
    • 2009
  • In the present study, a finite element analysis of conjugate heat transfer problem inside a cavity with a heat-generating conducting body, where constant heat flux is generated, is conducted. A conduction heat transfer problem inside the solid body is automatically coupled with natural convection inside the cavity by using a finite element formulation. A finite element formulation based on SIMPLE type algorithm is adopted for the solution of the incompressible Navier-Stokes equations coupled with energy equation. The proposed algorithm is verified by solving the benchmark problem of conjugate heat transfer inside a cavity having a centered body. Then a conjugate natural heat transfer problem inside a cavity having a heat-generating conducting body with constant heat flux is solved and the effect of the Rayleigh number on the heat transfer characteristics inside a cavity is investigated.