• Title/Summary/Keyword: 빛의 간섭

Search Result 123, Processing Time 0.026 seconds

Two Cases of Long-Term Changes in the Retinal Nerve Fiber Layer Thickness after Intravitreal Bevacizumab for Diabetic Papillopathy (당뇨병유두병증에서 유리체강내 베바시주맙 주입술 후 망막시경섬유층 두께의 장기간 변화 2예)

  • Kim, Jong Jin;Im, Jong Chan;Shin, Jae Pil;Kim, In Taek;Park, Dong Ho
    • Journal of The Korean Ophthalmological Society
    • /
    • v.54 no.9
    • /
    • pp.1445-1451
    • /
    • 2013
  • Purpose: To report long-term changes in the average retinal nerve fiber layer (RNFL) thickness in 2 patients who had intravitreal bevacizumab (IVB) injection for diabetic papillopathy. Case summary: A 36-year-old patient with diabetes complained of decreased visual acuity (20/200) in the right eye. The fundus examination showed optic disc swelling in both eyes. The average RNFL thickness based on optical coherence tomography (OCT) increased to $278{\mu}m$ and Goldmann perimetry showed nasal visual field defect in the right eye. The IVB was injected into the right eye. Three weeks after the IVB injection, RNFL thickness decreased to $135{\mu}m$ and visual acuity improved to 20/25 in the right eye. However, RNFL thickness increased from 126 to $207{\mu}m$ and visual acuity decreased to 20/32 in the left eye. Thus, IVB was injected into the left eye. In week 3, RNFL thickness decreased to $147{\mu}m$ and visual acuity improved to 20/20 in the left eye. At 12 months after IVB injection, RNFL thickness was $87{\mu}m$ in the right eye and $109{\mu}m$ in the left eye. A 57-year-old patient with diabetes complained of decreased visual acuity (20/200) and showed optic disc swelling in the right eye. The average RNFL thickness increased to $252{\mu}m$ and Goldmann perimetry showed an enlarged blind spot in the right eye. IVB was injected into the right eye. After 3 weeks, RNFL thickness decreased to $136{\mu}m$ and visual acuity improved to 20/70 in the right eye. Six months after IVB injection, RNFL thickness was $83{\mu}m$ in the right eye. Conclusions: Visual acuity progressively improved within 3 weeks and RNFL thickness measured by spectral domain OCT showed progressive thickness reduction in 2 cases of diabetic papillopathy patients who had IVB injections.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.

A Study on Face Awareness with Free size using Multi-layer Neural Network (다층신경망을 이용한 임의의 크기를 가진 얼굴인식에 관한 연구)

  • Song, Hong-Bok;Seol, Ji-Hwan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.149-162
    • /
    • 2005
  • This paper suggest a way to detect a specific wanted figure in public places such as subway stations and banks by comparing color face images extracted from the real time CCTV with the face images of designated specific figures. Assuming that the characteristic of the surveillance camera allows the face information in screens to change arbitrarily and to contain information on numerous faces, the accurate detection of the face area was focused. To solve this problem, the normalization work using subsampling with $20{\times}20$ pixels on arbitrary face images, which is based on the Perceptron Neural Network model suggested by R. Rosenblatt, created the effect of recogning the whole face. The optimal linear filter and the histogram shaper technique were employed to minimize the outside interference such as lightings and light. The addition operation of the egg-shaped masks was added to the pre-treatment process to minimize unnecessary work. The images finished with the pre-treatment process were divided into three reception fields and the information on the specific location of eyes, nose, and mouths was determined through the neural network. Furthermore, the precision of results was improved by constructing the three single-set network system with different initial values in a row.

Distribution, Life History and Growth Characteristics of the Utricularia japonica Makino in the East Coastal Lagoon, Korea (동해안의 석호에서 통발의 분포, 생활사 그리고 생장 특성)

  • Jeong, Yeon-In;Hong, Bo-Ram;Kim, Young-Chul;Lee, Kyu-Song
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.2
    • /
    • pp.110-123
    • /
    • 2016
  • In order to obtain scientific information for the conservation of Utricularia japonica Makino, rare plant species, we investigated life history, phenology, growth and distribution in the east coastal region of Korea. Seven habitats of U. japonica were confirmed in this study. Turion of U. japonica rests overwinter at the bottom and ripens at the water surface and then usually germinate and sprout when the water warms in spring. A single shoot grown from turion divided into several shoots. Shoot decomposition started in October and formed a new turion at the end of the decomposed shoot. Flowering period was from early July to late October. Percentage of flowering ramets was significantly low as 6.3%. U. japonica showed the fastest growth rate from April to July, the maximum growth in August and the highest biomass in October. U. japonica tended to be concentrated in larger ramets in the water depth of 50 cm~150 cm in Cheonjin lake. The main factors affecting the growth of U. japonica were water temperature and turbidity. The establishment and growth of U. japonica in Cheonjin lake were determined by responses to water temperature with seasonal change and to light conditions caused by the different plants. These conditions affect the temporal and spatial distribution of U. japonica and population change. The findings of this study would be helpful to provide the basic information needed for the conservation and restoration of U. japonica.

An Experimental Study on the Fire Monitoring System for Tunnel Using SMA and Fiber Optic Cable (형상기억합금과 광케이블을 이용한 터널의 화재감지 시스템 개발에 관한 실험적 연구)

  • Hwang, Ji-Hyun;Park, Ki-Tae;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.128-134
    • /
    • 2014
  • Recently, design and construction of street tunnels tend to focus on cost reduction and preservation of nature. Accordingly, research is actively being carried out to quickly detect fires when they occur in tunnels, which have partially closed structures. Among such research, fire detection methods using optical fiber sensors have a wide bandwidth and fast transmission speed, while using light as a medium. Therefore, it does not receive electrical interference and there is almost no loss of information during transmission, while also having little noise as well. In relation to this, a fire monitoring system that can accurately detect the location of fires in real time using shape memory alloy and optical cables was developed in this study. In order to verify the developed method, light loss measurement test was conducted according to indoor temperature changes, while also conducting fire simulation tests by installing test beds in common underground zones with different external environments of temperature and distance. Upon carrying out experiments, the fire monitoring system developed in this study was found to be able to detect fires in long distance sections in real time.

Studies on Various Test Conditions and Application of Test Method for Lipoxygenase-l in Soybean (콩의 Lipoxygenase-1 신속 검정방법 확립)

  • 조준형;김영미;윤홍태;김용호;김용욱;김명애
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.6
    • /
    • pp.739-747
    • /
    • 1997
  • This study was performed to clarify various conditions on the test of lipoxygenase-l and to establish the application of new test method for varietal improvement of soybeans in order to decrease beany flavors. Potassium borate and Tris were used as buffer and O.1M potassium borate solution showed the best result for the lipoxygenase-l test. In the range of pH 8.5~9.0 of the buffer, 2mM linoleic acid as substrate was effective. For color development, 100$\mu$l of two solutions(KI and starch) were added to the half soybean seed, successively. The substrate solution included linoleic acid was stored safely for 10 days at 4$^{\circ}C$ in refrigerator and for 4 days at room temperature. The best result was as follows; the 1ml of substrate solution[0.1M potassium borate(pH 9.0), 0.1% Tween-20, 2mM linoleic acid] was added to the chipped half soybean seed in l.5ml plastic tube, waited for 15 minutes, and 100$\mu$l of color development solutions(5% saturated KI in 15% acetic acid, 1% starch) were added to the tube, successively. After 4 hours, the purple color was observed in the upper phase of the plastic tube in the presence of lipoxygenase-1 and milky color in absence of lipoxygenase-1. The purple color was stable from 4 to 24 hours. There was no interfering effect by lipoxygenase-2 and -3. The plastic tube should be placed in the tube stand without shaking during the lipoxygenase-l test.

  • PDF

PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR (한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작)

  • Oh, T.H.;Park, K.C.;Kim, Y.H.;Yi, Y.;Kim, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.305-318
    • /
    • 2002
  • We have constructed two flight models of airglow photometer system (AGP) to be onboard Korea Sounding Rocket-III (KSR-III) for detection of MUV dayglow above the Korean peninsular. The AGP system is designed to detect dayglow emissions of OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ and background 3070${\AA}$ toward the horizon at altitudes between 100 km and 300 km. The AGP system consists of a photometer body, a baffle an electronic control unit and a battery unit. The MUV dayglow emissions enter through a narrow band interference filter and focusing lens of the photometer, which contains an ultraviolet sensitive photomultiplier tube. The photometer is equipped with an in-flight calibration light source on a circular plane that will rotate at the rocket's apogee. A bane tube is installed at the entry of the photometer in order to block strong scattering lights from the lower atmosphere. We have carried out laboratory measurements of sensitivity and in-flight calibration light source for the AGP flight models. Although absolute sensitivities of the AGP flight models could not be determined in the country, relative sensitivities among channels are well measured so that observation data during rocket flight in the future can be analyzed with confidence.

A Case of Unilateral Focal Pigmented Paravenous Retinochoroidal Atrophy (단안에 국소적으로 발현된 색소정맥옆망막맥락막 위축 1예)

  • Park, Hyo Song;Yang, Jong Yun;Park, Hyun Ju
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1190-1194
    • /
    • 2018
  • Purpose: We report a case of unilateral, focal, pigmented paravenous retinochoroidal atrophy (PPRCA). Case summary: A 46-year-old female visited our clinic in complaint of a vague problem with her right eye identified during a general medical examination. The visual acuity (without correction) of both eyes was 1.0. Slit-lamp examination of both eyes revealed no specific signs. Fundus examination of the right eye revealed focal, bony-spicule-shaped retinochoroidal atrophy with pigmentation along the course of the superior retinal vein. A fundus autofluorescence examination revealed principally hypofluorescence with some hyperfluorescence at the margin of the atrophic retinochoroidal lesion. Optical coherence tomography revealed mixed clumping and atrophy of the retinal pigment epithelium (RPE) layer and thinning of the choriocapillaris layer. Fluorescence angiography revealed a window defect and blockage at the site of the lesion (the fluorescent material did not enter the lesion). The site of the window defect was in correlation with the atrophic RPE region. The site of the blockage at lesion also matched with the site of the regional pigment clumping. No definite leakage was observed. Conclusions: To the best of our knowledge, this is the first case of unilateral focal PPRCA reported from Korea.

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.

Study of Correlation between Macular Thickness, Retina Nerve Fiber Layer Thickness and Axial Length according to Refractive Errors in Children (아동들의 굴절이상에 따른 안축장과 황반두께, 망막신경섬유층 두께의 상관성연구)

  • Choi, Hyung-Seok;Leem, Hyun-Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Purpose : We identified correlation between macular thickness and RNFL (retina nerve fiber layer) measured by OCT and axial length in Korean children divided as three groups according to refractive errors. Methods : In total, 134 eyes of 67 Korean children who experienced no eye disease and ophthalmology surgery were involved in this study and then divided as three groups such as hyperopic, emmetropic and myopic groups. Macular thickness and RNFL thickness were measured with Cirrus HD-OCT, and axial length was done with IOL Master.Macular thickness and RNFL thickness were measured by Cirrus HD-OCT, and axial length using IOL Master. Correlation between axial length and retinal thickness in three groups according to refractive errors was investigated. Results : The type of refractive error measured by axial length was myopic, emmetropic and hyperopic groups in order, showing significant difference (p<0.05). The center thickness of macular was myopic, emmetropic and hyperopic groups in order, showing significant difference(p<0.05). The thicknesses of superior, nasal and inferior regions in peripheral macula were the thinnest in myopic group (p<0.05). It was shown that positive correlation was found between the center thickness of macula and axial length (r=0.283, p<0.05), while negative correlation was found between the peripheral thickness of RNFL and axial length. The temporal thickness of RNFL represented the thickest in myopic group, showing positive correlation with axial length(r=0.39, p<0.05). The superior, nasal and inferior thickness of RNFL represented negative correlation with axial length, showing statistically significant in the nasal thickness of RNFL(r=-0.23, p<0.05). Conclusion : Through this study, we identified correlation between macular thickness, the thickness of RNFL and axial length using OCT in Korean children, and also found the differences in three refractive error groups.