• Title/Summary/Keyword: 빔 영상시스템

Search Result 133, Processing Time 0.03 seconds

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF

Design and Analysis of Coaxial Optical System for Improvement of Image Fusion of Visible and Far-infrared Dual Cameras (가시광선과 원적외선 듀얼카메라의 영상 정합도 향상을 위한 동축광학계 설계 및 분석)

  • Kyu Lee Kang;Young Il Kim;Byeong Soo Son;Jin Yeong Park
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.106-116
    • /
    • 2023
  • In this paper, we designed a coaxial dual camera incorporating two optical systems-one for the visible rays and the other for far-infrared ones-with the aim of capturing images in both wavelength ranges. The far-infrared system, which uses an uncooled detector, has a sensor array of 640×480 pixels. The visible ray system has 1,945×1,097 pixels. The coaxial dual optical system was designed using a hot mirror beam splitter to minimize heat transfer caused by infrared rays in the visible ray optical system. The optimization process revealed that the final version of the dual camera system reached more than 90% of the fusion performance between two separate images from dual systems. Multiple rigorous testing processes confirmed that the coaxial dual camera we designed demonstrates meaningful design efficiency and improved image conformity degree compared to existing dual cameras.

A Study on a Phase-encoded Multiplexing Method in Holographic Memory System (홀로그래픽 메모리시스템에서 위상 다중화 인코딩에 관한 연구)

  • Cho, Byung-Chul;Kim, Kyu-Tae;Gil, Sang-Keun;Kim, Eun-Soo
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.51-60
    • /
    • 1999
  • For an effective phase-multiplexing in holographic memory system, four types of phase code used as reference beam are generated. In case of $32 {\times} 32$ address beam, a phase error with 0%, 5%, 10% 15%, 20%, and 25% error rate, is purposely added to the real phase values in order to consider the practical SLM's nonlinear characteristics of phase modulation in computer simulation, cross talks and SNRs are comparatively analysed for these phase-codes by the auto and cross-correlation. Pseudo-Random(PSR) Phase Code has the lowest cross-correlation mean value of 0.067 among four types of Phase Code, which means the SNR of the PSR is higher than other Phase Codes. Also, the standard deviation of the PSR phase code indicating the degree of recalled data degradation is the lowest value of 0.0113.

  • PDF

Performance Analysis of Complex Phase-code for Phase Multiplexes Holographic Memory System (위상 다중화 홀로그래픽 메모리 시스템을 위한 CPC 위상코드의 성능 분석)

  • 조병철;김정진;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.1-8
    • /
    • 2003
  • In this paper, performance of the CPC(complex phase code) which is recently proposed as a practical phase encoding method for phase-code multiplexes holographic memory system is comparatively analyzed with those of the conventional phase codes such as PR(pure random code), RCE(random code with equality), WHM(Walsh Hadamard Matrix). In computer simulation, the size of an address bean is fixed at 32$\times$32 pixels and 0%-25% phase-error ratio in a pixel are intentionally added to the real phase values to consider the nonlinear phase-modulation characteristics of the practical spatial light modulator. From comparative analysis of crosstalks and signal-to-noise ratios for these phase codes by calculating auto-correlation and cross-correlation, it is found that the CPC have the lowest cross-correlation mean value of 0.021, the lowest standard deviation of 0.0113 and the highest signal-to-noise ratio(SNR) of 27.4 among the four types of phase code. In addition, from the calculation of the number of all possible address beams for these four types of phase code as the size of the address beam is fixed to 3232 pixels, the CPC is found to have 6.334$\times$10$^{49}$ address beams, which are relatively higher number than that of the conventional phase codes.

Digital Signage with Motion Graphics (모션 그래픽스의 디지털 사이니지 적용)

  • Park, Daehyuk
    • Journal of Digital Convergence
    • /
    • v.18 no.2
    • /
    • pp.377-383
    • /
    • 2020
  • Digital signage is constantly being researched as new digital video platform to replace existing signage market. Traditionally, It conveys various information combining still images with text. Nowadays, it is rapidly exchanging to multi digital platform by high specificaton system, improvement of internet speed and advancement of video and audio compression technology with HTML5 technology. Not only a single wide-screen display but also the combination and adjustment of screens with setop box, OLED, media facades, and lase beam projectors are transformed into various forms to enable creative and diverse attempts for graphic designers. This study focuses on the application of motion graphics in rapidly evolving future platform - digital signage, and looking forward to help digital video content creator, researchers, and motion graphic designers.

Sentence Recommendation Using Beam Search in a Military Intelligent Image Analysis System (군사용 지능형 영상 판독 시스템에서의 빔서치를 활용한 문장 추천)

  • Na, Hyung-Sun;Jeon, Tae-Hyeon;Kang, Hyung-Seok;Ahn, Jinhyun;Im, Dong-Hyuk
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.11
    • /
    • pp.521-528
    • /
    • 2021
  • Existing image analysis systems in use in the military field are carried out by readers analyzing and identifying images themselves, writing and disseminating related content, and in this process, repetitive tasks are frequent, resulting in workload. In this paper, to solve the previous problem, we proposed an algorithm that can operate the Seq2Seq model on a word basis, which operates on a sentence basis, and applied the Attention technique to improve accuracy. In addition, by applying the Beam Search technique, we would like to recommend various current identification sentences based on the past identification contents of a specific area. It was confirmed through experiments that the Beam Search technique recommends sentences more effectively than the existing greedy Search technique, and confirmed that the accuracy of recommendation increases when the size of Beam is large.

Study on Velocity In-homogeneous Effect in fat and its Correction in Ultrasound Imaging System (초음파 의료영상에서 지방조직의 음속도 불균일 효과의 영향과 그 보상에 관한 연구)

  • Kim, Jae-Hyeon;Bae, Mu-Ho;Jeong, Mok-Geun
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.9-18
    • /
    • 1998
  • In this paper, we present the degradation of focusing induced by velocity inhomogeneity in human tissue. For simulation, the fatty layer which is the major factor of degradation for its lower velocity, is modeled as a uniform velocity perturbation layer. And we simulate the degradation of resolution resulting from change of beam path due to refraction and the time delay due to velocity difference. We show that focusing error can be compensated for considering the velocity inhomogeneity only. The proposed compensation method can be operated in real time in the presently used digital focusing systems.

  • PDF

Three-dimensional Holographic Display with Twin Image Noise Rejection Using Off-axis Hologram Converting (탈 축 홀로그램 합성을 이용한 쌍 영상 잡음 제거와 3차원 홀로그램 디스플레이)

  • Kim, You-Seok;Kim, Tae-Geun;Kim, Jin-Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.328-333
    • /
    • 2009
  • We proposed a three-dimensional holographic display technique without twin image noise by converting a complex hologram to an off-axis hologram. To implement the proposed technique we record the complex hologram of a three dimensional object that is composed of two slides located with different depth locations. We added spatial carrier to the complex hologram and after that, extract the real part of the spatial-carrier-added hologram. This converts the complex hologram to an off-axis hologram. We also reconstruct the off-axis hologram using a spatial light modulator for three dimensional display.