• Title/Summary/Keyword: 빔의 안정도

Search Result 232, Processing Time 0.032 seconds

Wideband adaptive beamforming method using subarrays in acoustic vector sensor linear array (부배열을 이용한 음향벡터센서 선배열의 광대역 적응빔형성기법)

  • Kim, Jeong-Soo;Kim, Chang-Jin;Lee, Young-Ju
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.395-402
    • /
    • 2016
  • In this paper, a wideband adaptive beamforming approach for an acoustic vector sensor linear array is presented. It is a very important issue to estimate the stable covariance matrix for adaptive beamforming. In the conventional wideband adaptive beamforming based on coherent signal-subspace (CSS) processing, the error of bearing estimates is resulted from the focusing matrix estimation and the large number of data snapshot is necessary. To alleviate the estimation error and snapshot deficiency in estimating covariance matrix, the steered covariance matrix method in the pressure sensor is extended to the vector sensor array, and the subarray technique is incorporated. By this technique, more accurate azimuth estimates and a stable covariance matrix can be obtained with a small number of data snapshot. Through simulation, the azimuth estimation performance of the proposed beamforming method and a wideband adaptive beamforming based on CSS processing are assessed.

단원자 팁 기반 가스장 이온빔(Gas Field Ionization Beam)생성

  • Park, In-Yong;Jo, Bok-Rae;Han, Cheol-Su;An, Jong-Rok;;Kim, Ju-Hwang;Sin, Seung-Min;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.2-402.2
    • /
    • 2014
  • 과학과 기술이 발전할수록 나노크기를 넘어서 나노 크기미만의 관찰 분해능과 가공능력이 필수로 요구되어 측정장비와 가공장비의 연구 및 개발이 매우 중요하다. 현재는 주사전자현미경과 투과전자현미경의 발달로 나노크기 이하의 이미징 분해능에는 도달하였지만, 전자 입자의 가벼운 무게 때문에 가공측면에서는 한계를 가지고 있다. 또한 지난 수십 년간 정밀가공에 사용된 갈륨이온 LMIS(Liquid Metal Ion Source)기반의 집속이온빔 시스템은 수십 nm의 가공정밀도를 가지지만 10 nm 미만의 가공정밀도까지 구현하기에는 현재 기술적인 한계로 힘들다. 나노크기 이하의 이미징 분해능과 수 nm의 가공정밀도를 갖는 이온현미경이 최근에 상용화되어 판매되고 있는데, 이 이온 현미경에 사용되는 것이 가스장 이온원(GFIS:Gas Field Ionization Source)이다. 가스장 이온원은 작은 발산각, 작은 가상 이온원 크기 그리고 좁은 에너지 퍼짐의 특징을 가지며 이에 따라 구면수차 및 색수차에도 둔감한 특징을 가지고 있다. 또한 LMIS 는 갈륨이온이 시편속에 파고들어 시편의 물질 특성이 변화되는 문제가 있지만, GFIS에서는 주로 He, Ne 와 같은 불활성 기체를 주로 사용하므로 시편과 반응을 최소화 할 수 있는 장점도 있다. 위와 같은 특징을 갖는 이온빔을 GFIS 로 생성하고 이온현미경에 사용하기 위해서는 이온빔이 팁의 단원자 내지 수 개 정도의 원자에서 생성되도록 해야 한다. 본 연구에서는 GFIS 의 원리를 소개하고 장(전계)이온현미경(Field Ion Microscope)실험을 통하여 GFIS기반으로 생성된 이온빔의 형상을 보여준다. 또한 높은 각전류밀도 구현을 위하여 질소가스 에칭으로 텅스텐 팁 끝 단원자에서만 이온빔을 생성하고, 각전류 밀도 계산과 안정도 실험결과로 본 연구에서 개발한 이온원이 이온총으로서의 이온현미경 적용 가능성에 대해 보여준다.

  • PDF

EFFECT OF MAGNETIC FIELD STRUCTURE NEAR CATHODE ON THE ARC SPOT STABILITY OF FILTERED VACUUM ARC SOURCE OF GRAPHITE (자장 여과 진공 아크 소스에서 음극 부근의 자기장에 따른 아크 스팟 안정성 연구)

  • 김종국;이광렬;은광용;정기형
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.138-138
    • /
    • 1999
  • 자장 여과 진공 아크법(Filtered Vacuum Arc :FVA)에 의해 증착된 비정질 다이아몬드 박막은 기계적, 광학적 특성이 매우 우수하여 많은 연구자들의 관심의 대상이 되어 왔다. 그러나 아크의 불안정성은 자장 여과 아크 소스의 연속적인 운전을 제한하고, 결과적으로 낮은 생산성을 가져왔다. 본 연구에서는 음극의 형태 및 음극 부근에서의 자기장의 구조를 음극 부식 거동의 관점에서 수치모사 및 실험을 통해서 조사하였다. 소스 전자석과 인출 전자석의 자극 방향이 평행하게 된 구조에서 (magnetic mirror configuration), 음극 후면에 반대 방향의 자극을 가지는 영구자석을 돔으로서 아크 불안정성을 억제할 수 있었다. 또한 소스 전자석에 진동하는 전류를 인가함으로써 아크 스팟의 운동 면적을 효과적으로 확장할 수 있었다. 시간 변화에 따른 빔 전류의 변화로부터 테이프형 음극이 우물형 음극에 비하여 더 안정하다는 것을 확인하였다. 진동하는 소스 전자석의 전류와 직경 80mm의 테이퍼형 음극을 사용하여, 아크 전류 60A에서 약 2000분 동안 사용하였으며, 이때 부식된 부피는 사용 가능한 음극 부피의 약 90%였다. 그리고 약 350mA의 안정한 빔 전류를 현재의 조건에서 얻었다.

  • PDF

Roll-to-Roll 스퍼터 공정시 Ar 이온 빔 처리가 ITO 박막의 특성에 미치는 효과 연구

  • Sin, Yong-Hui;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.573-574
    • /
    • 2013
  • 본 연구에서는 Roll-to-Roll 스퍼터를 이용한 ITO 성막 공정에서 Ar 이온 빔 처리가 플렉시블 ITO 박막의 전기적, 광학적, 구조적 특성에 미치는 효과를 연구하였다. Roll-to-Roll 스퍼터를 이용하여 ITO 박막을 성막할 때 Linear ion source를 이용하여 Ar 이온을 ITO 박막에 직접 조사할 때 일어나는 ITO 박막의 변화를 분석하였다. Ar 이온 빔에 인가되는 DC 파워 변화에 따른 ITO 박막의 전기적, 광학적 특성 변화를 Hall measurement 및 UV/Visible spectrometry 분석법을 통해 확인하였다. 이온 빔 처리 공정 시 인가되는 파워가 DC 100 W일 때 $5.81{\times}10^{-4}{\Omega}-cm$으로 이온 빔 처리를 하지 않은 $1.14{\times}10^{-3}{\Omega}-cm$에 보다 낮은 비저항을 나타냄을 확인할 수 있었다. 이온 빔 처리 전/후 ITO 박막의 결정성은 포항 가속기 X-ray scattering법을 이용하여 분석하였으며, 결과를 통해 Ar 이온 빔 처리가 ITO 박막의 표면에서의 국부적인 결정성을 향상을 일으킴을 알 수 있었다. 이러한 결정성 향상이 Roll-to-Roll 스퍼터된 ITO 박막의 전기적 특성을 향상과 매우 밀접한 관계가 있음을 확인할 수 있었다. 또한 이온 빔 처리 전/후 ITO/CPI의 기판 휨에 따른 기계적 안정성을 알아보기 위해 bending frequency 60 Hz, bending radius 15mm로 bending test를 진행을 통하여 이온 빔 처리 전후 ITO 박막의 특성을 비교 확인하였다. 본 실험 결과를 통해 Ar 이온빔 조사에 의해 상온에서 결정형 ITO 박막을 CPI 기판위에 형성 할 수 있었다. 또한 최적화된 ITO 박막을 이용하여 유기 태양전지를 제작하였으며 이를 통해 Ar 이온빔 처리된 결정형 ITO의 유연 태양전지 응용 가능성을 타진하였다.

  • PDF

Transverse Profile Measurement of Proton Beam using the Beam Induced Fluorescence Monitor in KIRAMS-13 Cyclotron (Beam Induced Fluorescence 모니터를 이용한 KIRAMS-13 싸이클로트론의 양성자빔 횡단면 측정)

  • Nam, S.K.;Kim, K.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.418-425
    • /
    • 2009
  • To get the stable and optimized proton beam in the KIRAMS-13 cyclotron which installed in the regional cyclotron center, it is necessary to measure the transverse profile of proton beam. Beam Induced Fluorescence monitor is one of the non-destructive methods to measure the beam profiles, and it has many advantages such as a simple structure, real-time measurement, and minimum energy loss. The objective of this research is the design and development of Beam Induced Fluorescence monitor to measure the proton beam profiles in the KIRAMS-13 cyclotron.

Investigation of Liquid Crystal Alignment on ion beam exposed polystyrene surface (이온빔을 조사한 폴리스타일렌 기판에서의 액정의 배향특성)

  • Hwang, Hyun Suk;Lee, Jong-Deok;Rho, Jungkyu;Han, Jeong-Min
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.33-37
    • /
    • 2014
  • This paper introduces homogeneous liquid crystal (LC) orientations on chemically modulated polystyrene (PS) surfaces using various ion beam (IB) exposure time. Transparent PS was replaced with conventional polyimide material. As a non-contact process, IB bombardment process induced LC orientation in the direction parallel to the IB process. Through x-ray photoelectron spectroscopy, it was shown that the chemical compositional changes of the IB-irradiated PS surfaces were determined as a function of IB exposure time.Using this analysis, the optimal IB bombardment condition was determined at IB exposure time of up to 15 s. Moreover, thermal stability on IB-irradiated PS surfaces were carried out which showed that a relatively high IB exposure time induced a thermally stable LC alignment property.

전자빔 조사에 따른 Flexible ITO Film의 특성 향상에 대한 연구

  • Hwang, Jin-Ye;Nam, Sang-Hun;Kim, Yong-Hwan;Song, Gi-Mun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.581-581
    • /
    • 2013
  • ITO (Indium Tin oxide)는 비화학 양론적 조성을 띄는 n-type 반도체 특성이 있으며 가시광 영역(380~780 nm)의 파장에 대한 높은 광 투과도(>85%)를 가지며 비교적 높은 전도도(${\sim}10^4/{\Omega}-cm$)를 갖고 화학적 안정성이 우수하여 투명전극 박막으로 많이 사용되어왔다. 또한, PET film은 전기절연성, 내후성이 우수하고, 85%의 투과율을 보이는 특성에 의하여 Flexible display의 기판으로 많은 연구가 진행되고 있다. 이와 같은 PET film에 ITO를 증착하여 광 투과도와 전기전도도가 우수한 Flexible display의 투명전극으로 많은 연구 개발이 이루어지고 있다. Flexible ITO 박막의 특성을 향상하기 위해서는 $200^{\circ}C$ 이상의 열처리 공정이 필요하지만, PET는 약 $200^{\circ}C$ 이상에서 열 변형이 일어나므로 열처리 공정이 어렵고 이러한 문제점을 해결하기 위해 ITO/PET film에서 PET film의 변형 없이 ITO 박막의 표면에 전자빔 형태로 조사하여 박막의 물성을 개선하는 연구가 진행되고 있다 [1]. 본 연구에서는 ITO/$SiO_2$가 증착된 PET film에 전자빔을 조사하여 ITO 박막의 물성 변화를 관찰하였고, 전자빔 에너지 변화 및 전자빔 조사 시간에 따라 ITO film의 전기적, 광학적 특성 변화를 분석하였다. 구조적 특성은 XRD (X-ray diffraction), 전기적 특성은 4-point probe, Hall measurement를 이용하였으며, 가시광영역의 광 투과도는 UV-Vis spectrometer로 측정하였다. 전기 광학적 특성 변화는 Figure of Merit (FOM) 수치로 분석하였다. 이 실험으로 PET film에 직접적인 열을 가하지 않으면서 ITO 박막의 표면에 전자빔을 조사 하여, 박막의 전기전도도 및 광 투과율, 결정성 향상 등을 관찰할 수 있었다.

  • PDF

Effect of the Thermal Lensing on stable Region, Beam Waist and Astigmatic Compensation of Z-fold Cr4+ : YAG laser Cavity (Cr4+ : YAG 레이저에서 열 렌즈 효과에 따른 공진기의 안정영역과 빔 허리 및 비점수차의 보상)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.447-454
    • /
    • 2006
  • We obtained analytic solutions of boundary conditions to the stable region of Z-fold $Cr^{4+}$ : YAG laser cavity when the conditions are with and without thermal tensing effect. Also we investigated the influence of the thermal tensing effect on the stability of cavity, beam waist, and astigmatic compensation using aberration transformation matrices. The thermal tensing effect almost has no influence on the stable region of the cavity when the crystal is located in the middle of two concave mirrors and when the distances from the concave mirror to the reflecting mirror and the output coupler are the same. The beam waist, however, is affected more in a tangential plane than in a sagittal plane, and so it is difficult to have astigmatic compensation when the thermal tensing effect exists. This result means that the thermal tensing effect should be considered even for the Kerr-lens mode-locking.

The Emission and Characteristics Measurement of Electron Beam and Basis Construction for Education Usage (전자빔 인출 및 빔 계측과 교육 활용을 위한 기반구축)

  • Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.257-264
    • /
    • 2007
  • The MM22 microtron has used as a cancer therapy machine from Nov. 1986 to Feb. 2006. This machine was moved and installed to a radiation research center to use as an education and research tool from treatment machine because of aging of MM22 microtron. In this paper, for extracting the electron beam from microtron, operation principle of the microtron, system characteristics of each module, and pulse structures were reviewed. The beam extraction and measurement were performed after measuring pulses of each major module and extraction trials in the beam line. After finishing the movement of MM22 microtron, the 30mA target current in the case of 10 MV X-ray beam was extracted and the beam flatness of radiation distribution was acquired within 3% error ratio after 100 MU was irradiated on X-omatV Film at SSD 100 cm and field size $10{\times}10cm^2$. As a result, the microtron movement and new installation was performed with success.

  • PDF