• Title/Summary/Keyword: 비 침습

Search Result 710, Processing Time 0.028 seconds

Endoscopic Removal of Benign Endotracheal/Endobronchial Tumor (기도 내 양성 종양의 굴곡형 내시경하 절제술)

  • 문석환;왕영필;서종희;조건현;곽문섭;이선희
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.699-702
    • /
    • 2003
  • Endoscopic removal is acceptable for the treatment of endotracheal/endobronchial mass, because it is less invasive in high-risk patients and a conservative procedure for benign tumors. Two benign tumors in the lumen of the trachea (pure lipoma) and in the intermediate bronchus (hamartoma) were completely eradicated by our procedures, which involved diathermic snaring and residual mass removal with biopsy forceps under the guidance of fiberoptic bronchoscopy. No tumor recurrence was evident after extended follow-up (6 years for endotracheal lipoma and 2.5 years for endobroncheal hamartoma). Our method is safe and less invasive for the patient and provides the surgeon with better view during procedure.

TREATMENT FOR EPILEPSY PATIENT WITH BITING INJURY ON MENTOLABIAL SULCUS USING SOFT MOUTH GUARD : A CASE REPORT (Epilepsy 환아에서 야기된 이순구 교상을 soft mouth guard로 치료한 증례)

  • Kim, Tae-Wan;Kim, Young-Jin
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.4 no.1
    • /
    • pp.17-20
    • /
    • 2008
  • In the brain of epilepsy patients, sudden and unusually intense bursts of electrical charges are occurred repeatedly. So, epilepsy patient experiences seizure. Seizure shows various frequency and precipitating factor and has a prodrome. Also, epilepsy patient present various behavior pattern during seizure. If the biting injury occurred during seizure, there would be pain, infection, defect of soft tissue and esthetic problem. The dental management of self-mutilation includes preserve methods of using appliances such as lip bumper or soft mouth guard and radical methods such as extraction of all teeth or orthognathic surgery. A case of epilepsy patient with self-mutilation of mento-labial sulcus is presented. She was treated successfully with soft mouth guard.

  • PDF

Movement Control of a Car Based on Analysis of Brain EEG Signal (뇌파 EEG신호 분석 기반의 자동차 움직임 컨트롤)

  • Choi, YongHyeok;Seo, SeungWoo;Kwon, SeoGyoung;Kwon, SangEun;Lee, EunJu;Ko, ByoungChul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.1088-1090
    • /
    • 2017
  • 최근 국내에서는 상용화된 뇌파기반 인터페이스(BCI) 구현을 위한 연구가 활발히 진행되고 있다. 이에 본 논문에서는 안전한 비침습형 뇌파 측정 방법을 사용하여 뇌전도(EEG)를 측정하고 증폭된 데이터를 사용하여 RC카의 4방향 제어가 가능한 알고리즘을 제안한다. 뇌파측정기로 수집된 데이터 셋은 고속 푸리에 변환을 거쳐 사전 정의된 7가지 뇌파의 필터를 통해 집중도와 이완도를 검출하게 된다. 검출된 데이터는 아두이노 우노에 연결된 원격컨트롤러를 통하여 RC카의 전진 및 후진 제어를 담당한다. 또한 추가로 설치된 자이로센서를 통해 입력된 전자신호는 칼만 필터를 이용하여 좌회전 및 우회전 제어를 담당한다. 훈련된 실험자에 의해 실내 외에서 검출된 뇌파가 각기 다른 특성과 머리 회전만으로 상황을 구분하여 RC카 제어를 할 수 있음을 확인하였다.

Microwave Radiometry for functional Diagnosis of Biological tissue (생체 기능적 진단을 위한 Microwave Radiometry의 응용)

  • Lee, J.W.;Kim, K.S.;Lee, S.M.;Yoon, G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.845-847
    • /
    • 2000
  • 깊은 생체 조직에서 전자기 에너지의 일부가 피부로 전달되는데, 이때 생체 내부에서 피부로 전달되는 전자기 에너지의 세기는, 주파수 대역과 전자기파를 흡수, 반사, 투과시키는 인체의 매질에 따라 다르다. Microwave Radiometry는 인체 내부 조직에서 방출되는 1-6 GHz 대역의 전자기 에너지 일부를 피부 표면에서 측정하여 일정한 체적내의 인체 내부 온도 평균온도를 추정하는 방법이다. 이러한 Radiometry로 암이나 종양 등의 이상 조직을 진단하는 의학적 가설은, 암이 진행시 악성 종양의 세포의 신진대사가 정상 세포보다 활발하게 되고 또한 종양 세포 주위로 혈액의 유입이 증가하게되어, 주위의 정상 세포 보다 열을 보다 더 방출하는 데 있다. 이때 발생된 열은 일정한 주파수 대역의 마이크로파 에너지를 방출하게 되고, 이에 Radiometry로 인체에 무해하고(passive), 비침습적(non-invasive), 방사능의 영향이 없는 (non-ionizing) 방법으로 인체 내부에서 전달되는 전자기 에너지 강도를 측정하여 종양 부위와 주위 정상부위의 온도 차이를 추정 의학진단에 응용할 수 있다. 본 논문에서는 이러한 Microwave Radiometry의 의학적 응용과 생리학적 특성을 고려한 인체모델용 팬텀에 대하여 살펴본다.

  • PDF

Maximum exercise in 20 men Common carotid artery blood flow velocity impact (20대 남성에서 최대운동이 뇌로가는 혈관인 총경동맥 혈류 속도에 미치는 영향)

  • Kim, Ji-Won
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.5-12
    • /
    • 2009
  • Arterial blood from the heart chonggyeong passed directly to the cerebral arteries and the blood circulation is important, especially in arteries that prevent blood flow there are several variables. Among the variables the average flow velocity, pulse index, and blood flow resistance and which variables, double maekbakjisuna systolic and diastolic blood flow resistance index at the maximum rate and blood pressure associated with this because they are important variables, The change of variables such as speed noehyeolryu There are observations about the non-invasive ultrasound measurements using Doppler noehyeolryu uses. Up to 20 men in the exercise of noeroganeun hyeolryuin chonggyeong arteries to increase blood flow rates can be found.

  • PDF

Application of Radio Frequency Microwave Technique for Glucose Detection (포도당 검출을 위한 라디오 주파수 마이크로파의 적용)

  • Kim Tae-Woo;Park Byoung-Soo;Cho Dong-Uk;Han Khil-Sung;Cho Tae-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.4
    • /
    • pp.171-178
    • /
    • 2004
  • Radio frequency (RF) microwave can be used to predict glucose concentration in a sample. This paper presents preliminary results in determining the concentration by measuring relative permittivity in the solutions of distilled water, saline, human serum, and human blood containing glucose. It was shown that the microwave method has larger penetration depth of about 100times of NIR, than NIR technique in measuring glucose concentration for the tissue like a human muscle. The larger penetration depth of the method has advantages because it is more useful to detect glucose in a human body non-invasively. In the experiments, sensitivity for detecting glucose concentration in blood solutions was almost 57mg/dl at the frequency of approximately 5.8GHz.

  • PDF

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF

Vibration Analysis of the Temporomandibular Joint Sounds (측두하악 관절잡음의 진동 분석)

  • Jeong, Da-Un;Jeong, Jae-Hyeon;Gang, Dong-Wan
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.232-242
    • /
    • 2008
  • 관절잡음의 발생은 측두하악 관절의 구조적, 기능적 이상의 징후로 여겨져왔다. 이러한 관절잡음을 평가하는데 electrovibratography가 비침습적이고 신뢰할만한 방법으로 제시되어 왔으며 이를 통해 관절잡음의 진동수와 진폭 및 전체 에너지 양상을 숫자화하고 도식화 하는 것이 가능하게 되었다. 기존의 연구에서 여러 가지 관절잡음의 양적, 질적 분석이 시도되어 왔다. 이번 연구의 목적은 관절 잡음이 도식화되어 나타나는 frequency spectrum pattern을 integral>300Hz/<300Hz ratio와 함께 분석하는 것이다. 본 실험에서는 Joint Vibration AnalysisTM를 사용하여 측두하악 관절 장애의 증상이 없는 10명의 대조군과 관절 잡음과 동통이 있으나 개구제한을 보이지 않는 정복성 관절원판 변위의 범주에 있는 20명의 실험군에서 관절진동을 분석하였으며 관절진동 기록 시에 Jaw tracker를 함께 사용하여 개폐구시 관절잡음 발생의 위치를 감별하고 치아접촉음을 배제하여 관절잡음을 분석하였다. 그 후 실험군을 frequency spectrum pattern에 따라 4가지 하위 그룹으로 나누어 분석하였다. 실험 결과 실험군과 대조군의 하위 그룹 1에서 유사한 frequency spectrum pattern과 ratio범위를 보였으며 실험군의 하위 그룹 2,3,4 에서는 더 불규칙한 에너지 양상을 보이는 frequency spectrum pattern과 더 큰 ratio가 관찰 되었다. 이번 연구를 통해 Joint Vibration AnalysisTM가 악관절 진동의 특성을 감별하는데 유용함을 알 수 있었고 Joint Vibration AnalysisTM를 이용한 지속적인 진동 분석이 환자 교육뿐 아니라 성공적인 턱관절 기능이상의 진단과 치료에 유용할 것으로 사료된다.

  • PDF

Estimation of Causal Connectivity between Cortical Areas Using Near-Infrared Spectroscopy (NIRS) (근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석)

  • Lee, Seung-Deok;Go, Dal-Gwon;Jeong, Yeong-Jin;Kim, Do-Won;Im, Chang-Hwan;Kim, Beop-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.151-152
    • /
    • 2009
  • 최근 신경과학 분야에서 대뇌피질 영역 간 연관성 분석은 신경학적 질병 (자폐증, 간질, 정신 분열증)의 분석 및 진단에 적용되고 있다. 기존 대뇌피질 영역 간 연관성 분석은 뇌전도 (EEG), 기능적 자기공명영상 (fMRI), 뇌자도 (MEG)등이 이용되었지만, 뇌전도의 낮은 공간분해능, 기능적 자기공명영상의 낮은 시분해능 등은 영역 간 연관성 분석에 단점으로 작용되고 있다. 반면, 근적외선 분광법(NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxy-hemoglobin)를 비침습적이며 빠른 시분해능으로 측정할 수 있는 방법으로 최근 신경과학 분야에 응용되고 있다 [1-2]. 본 논문에서는 근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석의 효용성을 입증하기 위해, 쥐의 수염자극 시 대응되는 지역 (일차-, 이차 체감각피질, 일차 운동피질 영역)에서의 혈류변화 신호의 영역 간 연관성 분석을 하였다. 본 연구결과에 의하면 수염자극 시 일차-, 이차 체감각피질 영역에서의 방향성은 확인할 수 없었고, 일차-, 이차 체감각피질 영역에서 일차 운동피질영역으로의 방향성은 확인할 수 있었다. 본 결과는 기존 수염자극 시 활성화되는 전기신호의 패턴과 일치하며, 향후 신경과학적 질병의 분석 및 진단에 근적외선을 이용한 대뇌피질 영역 간 연관성 분석이 유용할 수 있음을 보여준다.

  • PDF

Laryngeal Evoked Electromyography with a Noninvasive Technique (비침습적 방법에 의한 후두유발근전도 검사)

  • 정성민;조선희;박기덕
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Background and Objectives : Laryngeal Evoked Electromyography(EEMG) is a objective, quantitative technique to determine innervation status of larynx. The possible applications of this technique are to confirm the etiology of impaired vocal fold motion and monitor perioperative vagus nerve trauma. The purpose of this study is to develop a novel method for determining the amount of reinnervation of recurrent laryngeal nerve with accurate, inexpensive, and minimally invasive technique in human. Materials and Methods : Laryngeal EEMG was performed for 16 adults with intact vocal folds motion and 2 patients diagnosed as unilateral vocal fold paralysis. for the purpose of searching what is the optimal and noninvasive technique for laryngeal EEMG, we used 2 types of stimulation configurations(transcutaneous vs percutaneous) and 2 types of recording configurations(intramuscular vs. surface). Results and Conclusions : Percutaneous needle stimulation and surface recording of laryngeal EEMG was reliable and comparable to standard needle stimulation and invasive intramuscular needle recording. But the laryngeal EEMG by the surface recording and transcutaneous surface stimulation was not reliable and repeatable. Therefore we recommended that laryngeal EEMG by surface recording and percutaneous needle stimulation would be minimally invasive, reliable technique to know the status of reinnervation in e patients with vocal fold paralysis.

  • PDF