• Title/Summary/Keyword: 비파괴진단방법

Search Result 120, Processing Time 0.022 seconds

Fundamental Study on Developing Embedded Mini-Sensor for Nondestructive Diagnosis Corrosion of Rebar (비파괴 철근 부식 진단을 위한 매립형 미니센서 개발에 관한 기초적 연구)

  • Joh, Sung-Hyung;Lim, Young-Chul;Ismail, Mohamed;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.179-187
    • /
    • 2010
  • Corrosion of rebar embedded reinforced concrete is the main cause of collapse and degradation of reinforced concrete structure. Degradation occurs in reinforced concrete structures from corrosion caused by the Chloride that the damage other than the severe degradation of the structure in terms of maintenance and construction when the huge expense required and deciding terms is hard. Therefore, early detection of rebar corrosion is important for efficient maintenance and repairing and planning. Meanwhile, how to evaluate the corrosion of the non-destructive measurements have been used a lot. In particular CM-II (corrosion meter) is used to measurement the natural potential, polarization resistance and the resistivity of the concrete, but has some disadvantages. Embedded mini-sensor has been developed in order to overcome these disadvantages. So Measurement corrosion for using the mini-sensor compares with the measured results CM-II (corrosion meter), the developed mini-sensor verify the validity.

Analysis of Aging Insulation Characteristics of 3.3[kV] Class Induction Motor with AC Breakdown Test (절연파괴시험법을 이용한 3.3[kV] 유도전동기의 절연물 열화특성 분석)

  • Lee, Ju;Kim, Hyun-Il;Kim, Youn-Hyun;Son, Yeoung-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.141-149
    • /
    • 2007
  • This paper introduce to improve the reliability of the expected service life and the insulation condition evaluation of the high voltage induction motors by assessing, comparing and analyzing the correlation between the dielectric properties of the off-line insulation diagnostic test and dielectric strength on the insulation breakdown test. The insulation diagnostic tests include insulation resistance, polarization index(P.I.), dissipation factor($tan{\delta}$), maximum partial discharges($Q_{max}$) and AC breakdown test. This study evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor. On the basis of these test results, we expect that this study can be used for effectively assessing the results of insulation diagnostic tests for similar class induction motors in service at industrial field.

A Study of the Development of PC-Based Source Location System using Acoustic Emission Technique (음향방출기법을 이용한 PC기반 위치표정시스템 개발에 관한 연구)

  • Lee, M.R.;Lee, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.205-211
    • /
    • 2003
  • Acoustic emission (AE) technique has been applied to not only mechanical property testing but also on-line monitoring of the el)tire structure or a limit zone only. Although several AE devices have already been developed for the on-line monitoring, the price of these systems is very high and it is difficult for the field to apply yet. In this study, wc developed a specially designed PC-based source location system using the A/D board. The source location technique is very important to identify the source, such as crack, leak detection. However, since the AE waveforms obtained from transducers are very difficult to distinguish the defect signals, therefore, it is necessary to consider the signal analyses of the transient waveform. Wavelet Transform (WT) is a powerful tool for processing transient signals with temporally varying spectra that helps to resolve high and low frequency transients components effectively In this study, the analyses of the AE signals are presented by employing the WT analyses. AE results are compared the PC-based source location system using A/D board with the commercial AE system.

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.

Self Diagnosis Technique of Concrete Structure Repaired and Strengthened by Carbon fiber Sheets Using Optical fiber Sensors (광섬유 센서를 이용한 탄소섬유시트 보수보강 콘크리트구조물에서의 자기진단기법)

  • Kim, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.2
    • /
    • pp.133-139
    • /
    • 2003
  • In order to extend the life time of building and civil infra-structure, nowadays, patch type fibrous composite materials are widely used. Repaired concrete columns and beams gain the stiffness and strength, but they lose toughness and show brittle failure. Usually, the cracks of concrete structures are visible with naked eyes and the status of the structure in the life cycle is estimated with visible inspection. After repairing of the structure, crack visibility is blocked by repaired carbon sheets. Therefore, structural monitoring after repairing is indispensible and self diagnosis method with optical fiber sensor is very useful. In this paper, peel-out effects is detected with optical fiber sensors and the strain difference between main structure and repaired carbon sheets when they separate each other.

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

경도측정을 이용한 고온 사용설비의 잔여수명 예측

  • 김재철;이해무
    • Journal of the KSME
    • /
    • v.32 no.4
    • /
    • pp.351-357
    • /
    • 1992
  • 고온 사용 설비의 잔여수명을 진단하는 비파괴적인 여러 가지 방법 중에서 현장에서 간단히 측 정을 함으로써 경년열화 정도를 비교적 쉽게 알아낼 수 있는 경도법에 대하여 살펴보았다. 이 방법은 크립손상 평가뿐만 아니라 피로 손상 평가에도 사용되고 있으며 외국의 경우 현장에서 많이 사용되고 있는, 가장 보편화된 방법 중의 하나이다. 국내의 경우에도 노후화된 고온 사용 설비가 상당수되기 때문에 설비의 안전성이나 경제적인 운용을 위해서 이들의 손상 정도를 정 기적으로 진단할 필요성이 매우 크나 이에 대한 연구 성과는 외국에 비하여 미미한 편이기 때 문에 앞으로 이에 대한 많은 노력이 이루어져야 한다고 생각되나. 특히 현장에서는 휴대용 시 험기를 사용하여야 하나 수명평가에는 비커스 경도값을 사용하고 있기 때문에 이들의 경도 환 산에 대한 D/B 확충이 시급한 실정이다. 또한 기존 기술의 습득 및 손상 평가의 정확도 향상, 새로운 방법들의 개발 그리고 이들의 현장 적용 등을 위해서는 실기 사용재의 입수, 정보교환, 전문가시스템(expert system) 개발을 위한 D/B 구축 등 산 . 학 . 연의 협동이 절실히 요구된다.

  • PDF

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Diagnosis of Pipe Structures using Impedance Measurement Sensor nodes (임피던스 측정 센서 노드를 이용한 배관 설비 진단)

  • Jang, In-Hwan;Jeong, Yeon-Wook;Song, Byung-Hun
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.367-369
    • /
    • 2009
  • 본 논문은 저전력 무선 임피던스 기반 구조물 건전성 감시 USN 시스템을 활용하여 electro-mechanical Impedance 센서의 일종인 PZT센서를 부착한 배관 구조물의 건전성을 진단하는 방법과 그 실험 결과에 대해 소개 한다. 기존에는 건설구조물에 가해지는 전기적인 입출력비에 해당하는 임피던스를 계측하기 위해서 비교적 고가의 대형 계측 장비가 필요로 했으며, 구조물에 설치된 센서를 계측장비에 연결하기 위한 유선의 케이블 작업 역시 추가로 필요했었다. 대형 배관 구조물의 경우에는 이러한 문제점 때문에 임피던스를 이용한 능동형 센서가 제대로 활용되지 못하고 있고 비정기적인 비파괴검사에만 국한되어 사용되어 왔다. USN기술은 저전력 소출력 무선통신을 통해 기존의 계측시스템과는 다른 상시모니터링의 장점을 가지고 있는 기술로서 최근 토목/건설 분야에서 적극적으로 활용이 되는 융합기술이다. 본 논문에서 구조물 건전성 감시 분야와 저전력 무선 계측 기술의 통합을 통해 얻어진 최적화된 배관 건전도 진단 센서 노드의 효율성을 정량적 실험 데이터를 통해 입증하고, 앞으로의 연구 방향에 대한 제안으로 끝을 맺는다.

  • PDF

Evaluation of Concrete Bridge Deck Deterioration Using Ground Penetrating Radar Based on an Extended Common Mid-Point Method (확장형 공통중간점법 기반 지표투과레이더를 이용한 콘크리트 교량 바닥판 열화 상태 평가)

  • Baek, Jong Eun;Lee, Hyun Jong;Oh, Kwang Chin;Eom, Byung Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.82-92
    • /
    • 2012
  • This study proposed a new non-destructive evaluation method for concrete bridge deck deterioration using ground penetrating radar (GPR). To calculate dielectric constant of the concrete bridge deck, an extended common mid-point (XCMP) method was developed for a two-layered structure using an air-coupled GPR antenna setup. The deterioration conditions of the concrete bridge deck such as deterioration depth was evaluated based on the dielectric constant and surface-to-average dielectric constant ratio of the concrete bridge deck. A GPR field test was conducted on an old concrete bridge with asphalt concrete surfacing to validate the new evaluation method. The test results showed that the newly proposed method estimated pavement thickness and deterioration depth of the concrete deck in a reasonable level.